Siemens 6AV7612-0AE10-0CJ0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AE10-0CJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7612-0AE10-0CJ0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is built around an industrial-grade PC architecture running on a Windows-based operating system, and is compatible with Siemens SIMATIC WinCC and ProTool/Pro visualization software. The unit provides standard PC interfaces including USB, serial (COM), and Ethernet ports for connectivity to PLCs and higher-level systems, and is designed for panel mounting with an IP65-rated front face for protection against dust and water ingress.
The SIMATIC Panel PC 670 is widely used in manufacturing, automotive, chemical processing, and machine building industries where a full PC-based HMI platform is required. Its compatibility with the SIMATIC software ecosystem makes it suitable for integration into existing Siemens automation architectures. The rugged construction and industrial-grade components make it appropriate for continuous operation in factory floor environments with elevated temperatures, vibration, and contamination.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Type | TFT LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Touch Technology | Resistive touchscreen |
| Input/Operating Voltage | 24 V DC |
| IP/Protection Rating | IP65 (front panel) |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Mounting | Panel mounting |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM) |
| Series/Product Family | SIMATIC Panel PC 670 |
| Operating System | Windows XP Embedded / Windows 2000 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 1000
- Application error in the WinCC or visualization runtime software, indicating an unexpected software fault or crash.
Restart the runtime application. Check the Windows event log for detailed error information and verify software installation integrity. - Event ID: 6008
- The previous system shutdown was unexpected, indicating a power loss or system crash occurred.
Check the 24 V DC power supply for stability and correct voltage levels. Inspect for loose connections at the power connector. - BIOS POST Error
- Power-On Self-Test failure detected during boot, indicating a hardware component fault such as RAM or storage device failure.
Check and reseat internal memory modules. Verify the CompactFlash card or hard disk is properly connected and functional. - WinCC Runtime Error
- WinCC runtime fails to start or terminates unexpectedly, often due to a corrupted project or licensing issue.
Verify the WinCC license is valid and installed. Restore the project from backup and check for corrupted configuration files. - Communication Error
- Loss of communication between the Panel PC and the connected PLC or automation controller.
Check Ethernet or serial cable connections. Verify IP address configuration and PLC communication settings in the HMI project. - Touchscreen Not Responding
- The resistive touchscreen fails to register input or is incorrectly calibrated.
Perform a touchscreen recalibration via the Windows control panel or SIMATIC settings. If unresponsive, check the touchscreen controller connection internally. - Temperature Warning
- Internal temperature of the Panel PC has exceeded the recommended operating threshold.
Check ambient temperature and ensure adequate ventilation around the panel cutout. Clean any dust from ventilation areas and verify the cooling fan operation if applicable.
Frequently Asked Questions
What display size and resolution does the 6AV7612-0AE10-0CJ0 have?
This Panel PC features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and resistive touch input.
What operating system does the SIMATIC Panel PC 670 (6AV7612-0AE10-0CJ0) support?
The unit supports Windows XP Embedded or Windows 2000, making it compatible with SIMATIC WinCC and ProTool/Pro visualization software.
What is the supply voltage for this Panel PC?
The 6AV7612-0AE10-0CJ0 operates on a 24 V DC supply voltage, typical for industrial panel-mounted devices.
What is the front panel protection rating of this unit?
The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, providing protection against dust and low-pressure water jets.
Is the 6AV7612-0AE10-0CJ0 compatible with Siemens S7 PLCs?
Yes, the Panel PC 670 can communicate with Siemens S7-300 and S7-400 PLCs via Ethernet or MPI/PROFIBUS interfaces using appropriate communication cards and SIMATIC software.
Troubleshooting
Panel PC does not power on after applying 24 V DC supply
Measure the supply voltage at the power input connector to confirm it is within the specified 24 V DC range. Check internal fuses if accessible.
Ensure the power supply is stable and within tolerance. Replace any blown internal fuses with the correct rating and verify the power connector is securely seated.
Display remains blank or shows no image after power on
Check whether the PC is booting by listening for disk activity or connecting an external monitor if supported. Verify the backlight is functioning.
If the PC boots but the display is blank, the backlight inverter or TFT panel may have failed. Replace the display assembly or backlight unit. If no boot activity is detected, investigate the mainboard or power supply.
Touchscreen input is inaccurate or unresponsive
Attempt to recalibrate the touchscreen through the Windows control panel. Check for physical damage or contamination on the screen surface.
Perform a full touchscreen recalibration. Clean the screen surface with a soft cloth. If the issue persists after recalibration, the touchscreen controller or digitizer may need replacement.
WinCC runtime project fails to load or crashes on startup
Review the Windows event log and WinCC diagnostic files for error messages. Check available storage space on the system drive.
Free up disk space if the drive is near capacity. Restore the WinCC project from a known-good backup. Reinstall the WinCC runtime if software corruption is suspected.
Ethernet communication to PLC is intermittent or lost
Check the Ethernet cable and RJ45 connector for damage. Verify the IP address and subnet mask settings in Windows network configuration match the network topology.
Replace the Ethernet cable if damaged. Reconfigure the network settings to ensure correct IP addressing. Update or reinstall the network adapter driver if the interface is not recognized.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page