• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AE10-0BH0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AE10-0BH0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AE10-0BH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AE10-0BH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel PC designed for demanding human-machine interface applications, combining computing power with a robust front panel suitable for direct machine or cabinet mounting. The unit integrates a flat-panel display with an embedded PC platform running a Windows-based operating system, providing a complete HMI and visualization solution in a single device.

    The SIMATIC Panel PC 670 features a 10.4-inch TFT color display with a resolution of 800 x 600 pixels (SVGA), offering clear visualization of process data. It is equipped with an Intel Celeron processor and supports standard PC interfaces including USB ports, serial COM ports, and Ethernet connectivity for integration into plant networks and PROFINET environments. The unit is designed with a fanless or low-maintenance cooling concept for the front panel area, an IP65-rated front face for protection against dust and water ingress, and is built to withstand the vibration and temperature conditions typical of industrial environments.

    The SIMATIC Panel PC 670 is widely used in the manufacturing, automotive, food and beverage, and process industries where a full PC-based HMI platform is required. It is suitable for applications demanding SCADA visualization, recipe management, data logging, and integration with Siemens SIMATIC WinCC or other SCADA software packages. Its rugged construction and industrial-grade components make it appropriate for continuous operation in production environments with elevated ambient temperatures and mechanical stress.

    Technical Specifications

    Display Size 10.4 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT Color LCD
    Display Colors 65,536 colors
    IP Protection Rating (Front) IP65
    Operating Voltage 24 V DC
    Operating Temperature 0 °C to 45 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Communication Interface Ethernet (RJ45), USB, RS-232 (COM ports)
    Mounting Panel mounting
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL
    Operating System Windows XP Embedded / Windows 2000

    Common Error Codes and System Events

    Event ID: 1000
    Application error – a software application on the Panel PC has encountered an unexpected fault and terminated.
    Check the Windows Event Viewer for detailed error logs. Reinstall or update the affected application. Verify that the operating system and drivers are up to date.
    Event ID: 6008
    Unexpected shutdown – the system was shut down unexpectedly, typically due to a power loss or hardware fault.
    Check the 24 V DC power supply for stability and correct voltage level. Inspect power connectors and wiring. Review Event Viewer logs for preceding errors.
    BIOS POST Error
    Hardware component not detected during Power-On Self-Test, such as missing RAM or storage device.
    Reseat RAM modules and CompactFlash or hard disk connections. Verify that all internal hardware is correctly seated and undamaged. Replace faulty components as required.
    WinCC Runtime Error
    SIMATIC WinCC or WinCC flexible runtime has failed to start or has crashed during operation.
    Check WinCC project configuration for errors. Verify that the correct runtime version is installed and licensed. Reinstall the WinCC runtime software if necessary.
    Network Communication Lost
    Ethernet communication to the PLC or network has been interrupted.
    Check Ethernet cable connections and switch/hub status. Verify IP address configuration and subnet settings. Check the PLC or server for communication faults on its end.
    Touchscreen Not Responding
    The touchscreen input is unresponsive or inaccurate, preventing operator interaction.
    Recalibrate the touchscreen using the Windows calibration utility. Check the touchscreen controller connection internally. If recalibration fails, replace the touchscreen assembly.
    Storage Device Failure
    The CompactFlash card or hard disk drive is not detected or has reported read/write errors.
    Check the storage device connection and reseat if necessary. Replace the CompactFlash card or HDD with a compatible unit. Restore the operating system and application software from backup.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7612-0AE10-0BH0?

    The SIMATIC Panel PC 670 operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel devices.

    What operating system does this Panel PC run?

    The 6AV7612-0AE10-0BH0 is designed to run Windows XP Embedded or Windows 2000, which are compatible with SIMATIC WinCC and WinCC flexible visualization software.

    What is the IP protection rating of this unit?

    The front panel of the 6AV7612-0AE10-0BH0 carries an IP65 protection rating, making it resistant to dust and water jets, suitable for direct panel mounting in industrial environments.

    Is this Panel PC compatible with Siemens SIMATIC WinCC?

    Yes, the SIMATIC Panel PC 670 is designed to run SIMATIC WinCC and WinCC flexible as its primary HMI visualization software, and is fully supported within the Siemens SIMATIC automation environment.

    What communication interfaces are available on this unit?

    The unit provides Ethernet (RJ45) for network and PROFINET connectivity, USB ports for peripherals and data transfer, and RS-232 serial COM ports for legacy device communication.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the power connector. Verify that the power LED indicator is active. Measure voltage at the internal power supply output to the display backlight.

    Ensure the 24 V DC supply is within tolerance. Replace the backlight inverter or display assembly if the supply is confirmed correct. Check and reseat internal display cable connections.

    Panel PC does not boot and shows no POST screen

    Attempt to access the BIOS by connecting an external keyboard via USB. Check whether the CompactFlash card or hard disk is detected in BIOS. Inspect RAM modules for proper seating.

    Reseat or replace the CompactFlash card or hard disk drive. Reseat RAM modules. If the unit still does not POST, the motherboard or processor module may require replacement.

    Touchscreen input is inaccurate or unresponsive

    Attempt touchscreen recalibration through the Windows control panel or calibration utility. Check for physical damage or contamination on the screen surface.

    Run the touchscreen calibration utility to realign input coordinates. Clean the screen surface. If the problem persists after recalibration, replace the touchscreen digitizer assembly.

    Ethernet communication to PLC is intermittent or lost

    Check the Ethernet cable and RJ45 connector for damage. Verify the IP address, subnet mask, and gateway settings in Windows network configuration. Test with a known-good cable.

    Replace the Ethernet cable if damaged. Reconfigure the network settings to match the plant network. Update or reinstall the Ethernet adapter driver if the interface is not recognized by the operating system.

    WinCC runtime application crashes repeatedly

    Review the Windows Event Viewer application log for error codes associated with the WinCC process. Check available disk space on the storage device and verify the WinCC license dongle or software license is present.

    Free up disk space if storage is near capacity. Reinstall the WinCC runtime software. Verify that the software license is valid and correctly installed. Update to the latest compatible WinCC service pack.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart