Siemens 6AV7612-0AE10-0AG0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AE10-0AG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface applications, combining a built-in display with a full PC platform running a Windows-based operating system. This unit integrates computing power and visualization into a single compact panel-mount enclosure suitable for use directly on the machine or in a control cabinet door.
The SIMATIC Panel PC 670 6AV7612-0AE10-0AG0 features a 15-inch TFT color display with a resolution of 1024 x 768 pixels (XGA) and resistive touch screen technology. It is powered by an Intel Celeron processor and supports standard PC interfaces including USB, serial (RS-232), and Ethernet (RJ45) for connectivity to PLCs and higher-level systems. The unit operates on 24 V DC supply voltage and is built to IEC 61131-2 environmental standards, with a fanless or low-noise cooling design suited to industrial environments. An integrated CompactFlash slot and hard disk drive option provide flexible storage configurations.
The SIMATIC Panel PC 670 is widely used in the automotive, food and beverage, pharmaceutical, and machine tool industries where a full PC-based HMI platform is required. It is particularly suited for applications demanding complex visualization, data logging, recipe management, and integration with SCADA or MES systems. Its panel-mount form factor and robust industrial design make it appropriate for installation in harsh production environments where reliability and long-term availability are critical.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 pixels (XGA) |
| Display Colors | 64,000 colors (TFT) |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Voltage Range | 19.2 V DC to 28.8 V DC |
| Processor | Intel Celeron |
| Operating System | Windows XP Embedded / Windows 2000 |
| Communication Interface | Ethernet RJ45, RS-232 (COM), USB |
| Storage | CompactFlash slot, optional hard disk drive |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
Common Error Codes and System Events
- Event ID: 100
- Operating system startup error — Windows failed to initialize correctly on boot.
Check CompactFlash or hard disk integrity. Restore or reinstall the operating system image using the Siemens recovery medium. - Event ID: 1000
- Application fault — A runtime or SCADA application has crashed unexpectedly.
Review Windows Event Viewer logs. Reinstall or update the HMI runtime software. Check for memory or storage issues. - Event ID: 10000
- Communication error to PLC — Loss of connection between Panel PC and the connected controller.
Verify Ethernet or serial cable connections. Check IP address configuration and firewall settings. Confirm PLC communication driver settings. - BIOS POST Error
- Hardware self-test failure detected during power-on self-test (POST).
Check that all internal modules (RAM, storage) are properly seated. If error persists, replace the defective hardware module or contact service. - Watchdog Timeout
- System watchdog has triggered due to software or hardware hang.
Identify and terminate the process causing the hang. Update or reinstall the runtime application. Check CPU load and memory usage. - Temperature Warning
- Internal temperature has exceeded the recommended operating threshold.
Verify ambient temperature is within 0–45 °C. Clean ventilation openings. Check that cooling fans (if fitted) are operational. - Storage Device Error
- CompactFlash card or hard disk drive is not detected or has failed.
Reseat or replace the CompactFlash card or HDD. Check BIOS storage detection. Restore the system image from backup.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AE10-0AG0?
The unit operates on 24 V DC with an acceptable input range of 19.2 V DC to 28.8 V DC.
What display size and resolution does this Panel PC have?
The 6AV7612-0AE10-0AG0 features a 15-inch TFT color display with a resolution of 1024 x 768 pixels (XGA) and a resistive touchscreen.
What communication interfaces are available on this unit?
The panel provides Ethernet (RJ45), RS-232 serial (COM port), and USB interfaces for connectivity to PLCs, networks, and peripherals.
What operating system does the SIMATIC Panel PC 670 run?
This unit supports Windows XP Embedded or Windows 2000, and is compatible with standard Siemens WinCC and SCADA runtime software.
What is the front panel protection rating of this device?
The front panel of the 6AV7612-0AE10-0AG0 is rated IP65, providing protection against dust and water jets, making it suitable for industrial panel-mount installation.
Troubleshooting
Display remains blank after power on
Measure the 24 V DC supply voltage at the power connector. Check the internal fuse and verify the power LED status on the unit.
Restore correct supply voltage within the 19.2–28.8 V DC range. Replace the internal fuse if blown. If the backlight is faulty, the display assembly or inverter board may require replacement.
Touchscreen does not respond or is misaligned
Check if the touch controller is recognized in Windows Device Manager. Determine whether the issue is a calibration problem or a hardware failure.
Recalibrate the touchscreen using the Windows calibration utility. If the touchscreen remains unresponsive, check the internal ribbon cable connection or replace the touchscreen overlay.
Panel PC fails to boot or shows BIOS error
Observe the POST screen for error messages. Check whether the CompactFlash card or hard disk is detected in BIOS settings.
Reseat the CompactFlash card or HDD. If the storage device is not detected, replace it and restore the operating system using the Siemens recovery image.
Loss of communication with PLC
Verify the Ethernet cable connection and check the IP address configuration in Windows network settings. Ping the PLC from the Panel PC to test connectivity.
Correct the IP address, subnet mask, or gateway settings. Replace the Ethernet cable if damaged. Reinstall or reconfigure the PLC communication driver (e.g., Siemens S7 DCOM or OPC server).
Unit overheating or shutting down unexpectedly
Check the ambient temperature around the panel. Inspect ventilation slots for blockages and verify that any cooling fans are operating correctly.
Ensure the installation environment is within the 0–45 °C operating range. Clean dust from ventilation openings. If a cooling fan has failed, replace it to restore adequate airflow.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page