Siemens 6AV7612-0AB30-0CG0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AB30-0CG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface applications, combining a touch-enabled display with a full PC platform running Windows-based operating systems. This unit integrates computing power and visualization into a single compact front-panel device suitable for cabinet or console mounting.
The SIMATIC Panel PC 670 6AV7612-0AB30-0CG0 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch technology for operator input. It is powered by an Intel Celeron processor and supports standard PC interfaces including USB, PS/2, and serial COM ports, as well as an Ethernet interface for network connectivity. The unit is designed for 24 V DC supply voltage and is built to IEC 61131-2 environmental standards, with a fanless or low-noise cooling design suited to industrial environments. An integrated CompactFlash slot or hard disk drive provides local storage for the operating system and application data.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine visualization applications across industries such as automotive, food and beverage, chemical processing, and packaging. Its rugged construction and IP65-rated front panel make it suitable for installation in environments with dust and moisture exposure. The platform is compatible with Siemens WinCC and other SCADA or HMI software packages, making it a practical choice for operators requiring a full PC environment at the machine level.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT Color LCD |
| Touch Technology | Resistive |
| Input Voltage | 24 V DC |
| Processor | Intel Celeron |
| Operating System | Windows XP / Windows 2000 (factory configurable) |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM), PS/2 |
| Storage | CompactFlash or Hard Disk Drive |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check CompactFlash card or hard disk drive for corruption. Re-image the storage medium with the correct OS image and verify BIOS boot order settings. - Event ID: 200
- Touchscreen calibration lost or touch input not responding correctly.
Re-run the touchscreen calibration utility from the Windows Control Panel. If the issue persists, check the touch controller ribbon cable connection internally. - Event ID: 300
- Ethernet communication link failure or network interface not detected.
Verify Ethernet cable connection and network switch port status. Check Device Manager for driver errors and reinstall the network adapter driver if necessary. - Event ID: 400
- Internal temperature threshold exceeded; thermal warning generated.
Check that ventilation clearances around the panel are maintained. Inspect and clean any air filters or ventilation slots. Verify ambient temperature is within specification. - Event ID: 500
- 24 V DC supply undervoltage detected; system may shut down or behave erratically.
Measure the 24 V DC supply at the power connector. Ensure the supply is within the specified tolerance range and check wiring for voltage drop. - Event ID: 600
- USB device not recognized or USB port fault.
Disconnect and reconnect the USB device. Try an alternative USB port. Check Device Manager for driver conflicts and update or reinstall USB drivers as needed. - Event ID: 700
- WinCC Runtime or HMI application crash or unexpected termination.
Review the Windows Event Log for application error details. Reinstall or repair the WinCC Runtime installation. Check for software version compatibility with the OS image.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AB30-0CG0?
The SIMATIC Panel PC 670 6AV7612-0AB30-0CG0 operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel devices.
What display size and resolution does this Panel PC have?
This unit features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch input.
Is the front panel of the 6AV7612-0AB30-0CG0 rated for dusty or wet environments?
Yes, the front panel carries an IP65 protection rating, making it suitable for environments with dust and water spray. The rear of the unit is rated IP20.
What HMI or SCADA software is compatible with this Panel PC?
The SIMATIC Panel PC 670 is compatible with Siemens WinCC, WinCC flexible, and other standard Windows-based SCADA or visualization software packages.
What communication interfaces are available on this unit?
The 6AV7612-0AB30-0CG0 provides Ethernet (RJ45), USB ports, RS-232 serial (COM) ports, and PS/2 connectors for keyboard and mouse connectivity.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector using a multimeter. Verify that the supply is within tolerance and that the power LED indicator is active.
If supply voltage is correct but display remains blank, inspect the internal display cable connections. Replace the backlight inverter or TFT display panel if the backlight has failed.
Touchscreen does not respond or registers incorrect touch positions
Attempt to recalibrate the touchscreen using the Windows calibration utility. Check if the touch overlay glass is physically damaged or contaminated.
Perform a full touchscreen recalibration. Clean the touch surface with a soft cloth. If calibration fails repeatedly, the resistive touch overlay may need replacement.
Unit fails to boot or continuously restarts
Connect an external keyboard and monitor via the available ports to observe POST messages. Check the CompactFlash card or hard disk drive for physical damage or corruption using diagnostic tools.
Re-image the storage medium with a valid OS image. If the unit still fails to boot, test with a known-good CompactFlash card. A failed internal power supply module may also cause this symptom.
Ethernet communication is not established
Verify the Ethernet cable and switch port are functional. Open Device Manager in Windows and check for errors on the network adapter. Ping the gateway to confirm network-level connectivity.
Reinstall the Ethernet adapter driver using the correct driver package for the installed OS. Check IP address configuration and firewall settings. Replace the Ethernet cable if physical damage is suspected.
System overheats and shuts down unexpectedly
Check the ambient temperature around the panel installation. Verify that the minimum clearance distances around the unit are maintained as specified in the installation manual.
Improve cabinet ventilation or add forced-air cooling to reduce ambient temperature. Ensure no ventilation slots are blocked. If the unit continues to overheat within specification, inspect internal thermal paste on the processor heatsink.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page