• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AB30-0AH0 Mobile Panel 170
    Awaiting product image

    Siemens 6AV7612-0AB30-0AH0 Mobile Panel 170

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AB30-0AH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AB30-0AH0 is a Mobile Panel 170, part of the SIMATIC HMI Mobile Panel series from Siemens. It is a portable, handheld operator panel designed for flexible machine operation and monitoring directly at the point of use. The unit features a compact, rugged housing suitable for industrial environments where mobility is required.

    The Mobile Panel 170 is equipped with a 5.7-inch STN color display with a resolution of 320 x 240 pixels (QVGA), providing clear visualization of process data and machine states. It connects to the control system via a PROFIBUS DP interface using a coiled cable and junction box, enabling communication with SIMATIC S7 PLCs. The panel includes a configurable membrane keypad with function keys, a built-in enabling button (dead man's switch) for safe operation, and an emergency stop button, making it suitable for safety-relevant applications. Configuration is performed using WinCC flexible or STEP 7 software.

    The Mobile Panel 170 is widely used in manufacturing, automotive assembly, machine tool, and process industries where operators need to move freely around a machine or production line while maintaining full control and monitoring capability. Its integrated safety features, including the enabling switch and emergency stop, make it particularly suitable for applications requiring close proximity to moving machinery, such as robot cells, conveyor systems, and large-format machine tools.

    Technical Specifications

    Display Size 5.7 inch
    Display Resolution 320 x 240 pixels (QVGA)
    Display Type STN color LCD
    Display Colors 256 colors
    Input/Operating Voltage 24 V DC
    Communication Interface PROFIBUS DP
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP/Protection Rating IP65 (front), IP54 (rear)
    Safety Features Integrated enabling button (3-position), Emergency stop button
    Series/Product Family SIMATIC HMI Mobile Panel 170
    Configuration Software WinCC flexible 2004 or higher
    Certifications CE, UL, cUL

    Common Error Codes and System Events

    Event ID: 10000
    Communication error between the Mobile Panel and the connected PLC or PROFIBUS network. The panel cannot establish or maintain a connection.
    Check the PROFIBUS cable and junction box connections. Verify the PROFIBUS address settings on the panel and PLC. Ensure the network termination resistors are correctly set.
    Event ID: 10001
    Project download error. The configuration project could not be transferred to the Mobile Panel.
    Verify the communication settings in WinCC flexible match the panel configuration. Check the transfer cable or network connection. Ensure the correct panel type is selected in the project.
    Event ID: 20000
    Enabling switch not actuated or released. The enabling button is not in the active (middle) position during operation in enabling mode.
    Instruct the operator to hold the enabling switch in the middle position. Check the enabling switch for mechanical wear or damage. Replace the enabling switch if it does not return a valid signal.
    Event ID: 20001
    Emergency stop activated. The integrated emergency stop button has been pressed.
    Identify and resolve the cause of the emergency stop activation. Unlock the emergency stop button by rotating it, then reset the fault condition in the PLC before resuming operation.
    Event ID: 40000
    Internal device error or hardware fault detected within the Mobile Panel.
    Perform a power cycle of the panel. If the error persists, back up the project and perform a factory reset. Contact Siemens technical support or arrange for repair if the fault recurs.
    Event ID: 50000
    Operating system or firmware error. The panel firmware may be corrupted or incompatible.
    Update the panel firmware to the correct version using the ProSave tool. Ensure the firmware version is compatible with the WinCC flexible project version being used.
    Event ID: 60000
    Configuration or project error. The loaded project contains errors or is incompatible with the panel hardware.
    Reload the project from WinCC flexible. Validate the project for errors before transfer. Ensure the project was compiled for the Mobile Panel 170 hardware variant.

    Frequently Asked Questions

    Which PLCs are compatible with the Mobile Panel 170 (6AV7612-0AB30-0AH0)?

    The Mobile Panel 170 communicates via PROFIBUS DP and is primarily designed for use with Siemens SIMATIC S7-300 and S7-400 PLCs. It can also communicate with other PROFIBUS DP-capable controllers.

    What software is required to configure and program this Mobile Panel?

    The Mobile Panel 170 is configured using Siemens WinCC flexible 2004 or a later compatible version. The ProSave tool is used for firmware updates and panel management.

    What safety functions are integrated into the Mobile Panel 170?

    The panel includes a three-position enabling switch (dead man's switch) and a hardwired emergency stop button. These safety features allow safe operation in close proximity to moving machine parts.

    What is the supply voltage for the 6AV7612-0AB30-0AH0?

    The Mobile Panel 170 is powered by 24 V DC, supplied through the junction box and coiled connecting cable.

    Can the Mobile Panel 170 be used outdoors?

    The panel is rated IP65 on the front and IP54 on the rear, providing protection against dust and water jets. It is suitable for indoor industrial use and protected outdoor locations, but direct exposure to sunlight and rain should be avoided.

    Troubleshooting

    Display remains blank after power on

    Check that 24 V DC is present at the junction box and that the coiled cable is securely connected at both ends. Measure voltage at the panel connector. Inspect the cable for damage.

    Restore the 24 V DC supply if absent. Replace a damaged coiled cable or junction box. If power is confirmed but the display remains blank, the internal display or power supply board may require repair or replacement.

    PROFIBUS communication fault or no connection to PLC

    Verify the PROFIBUS address configured on the Mobile Panel matches the address expected by the PLC program. Check the PROFIBUS cable for continuity and correct termination at both ends of the network segment.

    Correct the PROFIBUS address in the panel settings. Replace or re-terminate the PROFIBUS cable. Ensure the junction box PROFIBUS connections are secure and that only the two network endpoints have termination resistors enabled.

    Enabling switch does not function or generates a fault

    Test the enabling switch by pressing it to the middle position and observing the panel response. Check for mechanical damage or contamination on the switch. Verify the enabling switch wiring in the junction box.

    Clean the enabling switch if contaminated. If the switch is mechanically worn or produces no signal, replace the enabling switch assembly. Verify junction box wiring matches the installation diagram.

    Project cannot be transferred to the panel

    Confirm the transfer mode is active on the Mobile Panel (accessible via the Start Center or transfer settings). Check the communication cable or network connection between the engineering PC and the panel.

    Activate transfer mode on the panel before initiating download from WinCC flexible. Ensure the correct IP address or PROFIBUS address is configured in the project transfer settings. Replace the transfer cable if communication cannot be established.

    Panel restarts repeatedly or shows a continuous boot loop

    This may indicate a corrupted firmware or project file. Attempt to access the Start Center during boot by pressing the appropriate key combination. Check if the panel enters transfer mode.

    Use the ProSave tool to perform a firmware restore or factory reset via the serial or USB interface. Reload a validated project after the firmware is successfully restored. If the boot loop persists, the panel may require hardware-level repair.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart