Siemens 6AV7612-0AB22-0CH0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AB22-0CH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and robust solution for process visualization and machine control.
The SIMATIC Panel PC 670 6AV7612-0AB22-0CH0 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs on Microsoft Windows operating systems, providing a familiar environment for SCADA and HMI software deployment. The unit includes standard PC interfaces such as USB, serial (RS-232), and Ethernet (RJ45), and is designed for front-panel mounting with an IP65-rated front bezel for protection against dust and water ingress.
The SIMATIC Panel PC 670 is widely used in manufacturing, process industries, and machine building where a full PC-based HMI platform is required. Its compatibility with Siemens WinCC and other SCADA software packages makes it suitable for complex visualization tasks, data logging, and process control in industries such as automotive, food and beverage, chemical processing, and utilities. The panel-mount form factor allows direct integration into control cabinets and operator panels on the production floor.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Type | TFT Color LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Touch Technology | Resistive Touch Screen |
| Input/Operating Voltage | 24 V DC |
| IP/Protection Rating | IP65 (front panel) |
| Communication Interface | Ethernet RJ45, RS-232 (COM), USB |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 95% (non-condensing) |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
| Operating System | Windows XP / Windows 2000 |
Common Error Codes & System Events
- Event ID: 100
- System startup failure or BIOS POST error detected during boot sequence.
Check hardware connections, reseat memory modules and expansion cards. Verify BIOS settings and restore defaults if necessary. - Event ID: 200
- Operating system boot failure or corrupted system partition.
Boot from recovery media and repair or reinstall the operating system. Check hard disk or CompactFlash card for errors. - Event ID: 300
- WinCC Runtime communication error with PLC or controller.
Verify Ethernet or MPI connection settings, check IP address configuration, and confirm PLC is online and reachable. - Event ID: 400
- Touch screen calibration error or touch input not responding correctly.
Re-run the touch screen calibration utility from the Windows Control Panel. If unresponsive, check touch controller driver and cable connections. - Event ID: 500
- Fan failure or CPU thermal warning threshold exceeded.
Clean cooling vents and fan assembly. Verify fan operation. If fan is faulty, replace the internal cooling fan module. - Event ID: 600
- Storage device (HDD or CompactFlash) read/write error or device not detected.
Check storage device seating and connections. Run disk diagnostics. Replace HDD or CompactFlash card if errors are confirmed. - Event ID: 700
- 24 V DC supply undervoltage detected.
Measure supply voltage at the power input connector. Ensure the power supply unit provides a stable 24 V DC within specified tolerance.
Frequently Asked Questions
What is the display size and resolution of the 6AV7612-0AB22-0CH0?
This unit features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and a resistive touch screen.
What operating system does the SIMATIC Panel PC 670 6AV7612-0AB22-0CH0 support?
The unit supports Microsoft Windows XP and Windows 2000, providing compatibility with Siemens WinCC and other standard HMI and SCADA software packages.
What is the supply voltage for this Panel PC?
The 6AV7612-0AB22-0CH0 operates on a 24 V DC supply voltage, typical for industrial panel-mounted devices.
What communication interfaces are available on this unit?
The panel PC provides Ethernet (RJ45), RS-232 serial (COM port), and USB interfaces for connectivity to PLCs, networks, and peripherals.
Is the 6AV7612-0AB22-0CH0 compatible with Siemens WinCC?
Yes, this Panel PC is designed to run Siemens WinCC and other SCADA visualization software, making it suitable for integration into Siemens automation systems.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power input connector. Verify the power LED status and listen for fan operation to determine if the unit is receiving power.
Ensure the 24 V DC supply is within tolerance. If power is confirmed but display remains blank, check the display backlight inverter and internal display cable connections. Replace the backlight or display assembly if faulty.
Touch screen does not respond or responds inaccurately
Attempt to operate the unit using a USB mouse to determine if the issue is isolated to the touch screen. Check Device Manager for touch controller errors.
Re-run the touch screen calibration utility. Update or reinstall the touch screen driver. If hardware damage is suspected, inspect the touch overlay cable and replace the touch screen assembly if necessary.
Unit fails to boot into Windows operating system
Observe the boot sequence for BIOS POST errors. Check if the storage device (HDD or CompactFlash) is detected in BIOS settings.
Run disk diagnostics on the storage device. If the storage medium is corrupted or failed, restore the operating system from a backup image or replace the HDD/CompactFlash card and reinstall the OS.
WinCC or HMI application loses communication with PLC
Check the Ethernet or serial connection between the Panel PC and the PLC. Verify IP address settings and network configuration in WinCC channel settings.
Confirm network cable integrity and switch/hub operation. Verify correct IP address, subnet mask, and gateway settings. Restart the WinCC runtime and re-establish the communication channel.
Unit overheats or shuts down unexpectedly
Check the ambient temperature around the panel PC. Inspect cooling vents and fan for blockage or dust accumulation.
Clean all cooling vents and the internal fan using compressed air. Ensure adequate ventilation around the panel cutout. If the fan is not operating, replace the cooling fan module to restore thermal management.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page