• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AB22-0AF0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AB22-0AF0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AB22-0AF0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AB22-0AF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and rugged solution for process visualization and machine control.

    The SIMATIC Panel PC 670 (6AV7612-0AB22-0AF0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports 65,536 colors. It is equipped with an Intel Celeron processor and runs on Microsoft Windows operating systems, supporting SIMATIC WinCC and other Siemens HMI software packages. The unit provides standard PC interfaces including USB, serial (RS-232), parallel, and Ethernet ports, and supports integration into PROFIBUS and Industrial Ethernet networks. The front panel meets IP65 protection rating for resistance to dust and water ingress.

    The SIMATIC Panel PC 670 is widely used in the manufacturing, automotive, food and beverage, chemical, and pharmaceutical industries. It is suited for applications requiring a full PC-based HMI platform with the ability to run complex SCADA and visualization software alongside standard PC applications. Its rugged industrial design and front-panel IP65 rating make it appropriate for installation in control cabinets and machine panels in harsh production environments.

    Technical Specifications

    Display Size 12 inch
    Display Type TFT LCD
    Display Resolution 800 x 600 pixels (SVGA)
    Display Colors 65,536 colors
    IP Protection Rating (Front) IP65
    Operating Voltage 24 V DC
    Communication Interface Ethernet (RJ45), RS-232, USB, Parallel
    Operating System Windows XP / Windows 2000
    Series/Product Family SIMATIC Panel PC 670
    Mounting Panel mounting
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 95% (non-condensing)
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    System startup error — the operating system failed to boot correctly or a critical system file is missing.
    Check the hard disk or CompactFlash card for errors. Reinstall the operating system or restore from a system backup if necessary.
    Event ID: 1000
    Application fault — the HMI or SCADA application (e.g. WinCC) has crashed unexpectedly.
    Review the Windows Event Viewer for application error details. Reinstall or repair the HMI software and check for software compatibility issues.
    Event ID: 7000
    Service failed to start — a required Windows service did not start during boot.
    Check the Windows Event Viewer for the specific service name. Verify service configuration and dependencies, and restart the service manually if possible.
    Hardware Error
    A hardware component such as RAM, hard disk, or processor is reporting a fault, indicated by POST error messages on startup.
    Run hardware diagnostics. Reseat RAM modules and check all internal connections. Replace faulty hardware components as identified.
    No Boot Device Found
    The Panel PC cannot find a bootable device (hard disk or CompactFlash) during startup.
    Check that the storage medium is properly seated and recognized in BIOS. Replace the hard disk or CompactFlash card if it has failed, and restore the operating system image.
    Fan Failure Warning
    The internal cooling fan has stopped or is running below the required speed, risking overheating.
    Inspect and clean the fan and ventilation openings. Replace the internal fan if it is not operating correctly.
    WinCC Runtime Error
    SIMATIC WinCC runtime has encountered an internal error and cannot continue normal operation.
    Restart the WinCC runtime application. Check the WinCC diagnostic log files for root cause. Reinstall WinCC if errors persist.

    Frequently Asked Questions

    What display size and resolution does the 6AV7612-0AB22-0AF0 have?

    This unit features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports 65,536 colors.

    What is the front panel protection rating of this Panel PC?

    The front panel of the SIMATIC Panel PC 670 (6AV7612-0AB22-0AF0) carries an IP65 protection rating, making it resistant to dust and water jets.

    What HMI software is compatible with this Panel PC?

    The unit is compatible with SIMATIC WinCC, WinCC flexible, and other standard PC-based HMI and SCADA software packages that run on Windows XP or Windows 2000.

    What communication interfaces are available on this unit?

    The 6AV7612-0AB22-0AF0 provides Ethernet (RJ45), RS-232 serial, USB, and parallel interfaces, and can be integrated into PROFIBUS and Industrial Ethernet networks via appropriate adapters or cards.

    What is the supply voltage for this Panel PC?

    The SIMATIC Panel PC 670 operates on a 24 V DC supply voltage, which is standard for industrial panel-mounted devices.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power connector. Verify that the power LED is illuminated. Measure voltage at the internal power supply output rails.

    Ensure the 24 V DC supply is within tolerance. If the internal power supply has failed, replace it. If the display backlight has failed, replace the backlight inverter or the display assembly.

    Panel PC does not boot into the operating system

    Observe POST messages on startup. Check BIOS to confirm the boot device (hard disk or CompactFlash) is detected. Listen for hard disk activity.

    If the storage device is not detected, reseat or replace the hard disk or CompactFlash card. Restore the operating system image from a backup. If BIOS settings have been lost, reconfigure and save BIOS settings.

    Touchscreen does not respond to input

    Check if the touchscreen controller is recognized in Windows Device Manager. Verify that the touchscreen calibration has not been corrupted.

    Recalibrate the touchscreen using the Windows calibration utility. If the touchscreen controller driver is missing or corrupt, reinstall the driver. Replace the touchscreen overlay if physical damage is present.

    Unit overheats and shuts down unexpectedly

    Check that all ventilation openings are clear of obstructions. Verify that the internal fan is operating. Measure ambient temperature around the unit.

    Clean all ventilation slots and filters. Replace the internal cooling fan if it has failed. Ensure the ambient operating temperature does not exceed 45 °C and that adequate clearance is maintained around the unit.

    Ethernet communication is not established

    Check the Ethernet cable and switch port. Verify IP address configuration in Windows Network Settings. Check if the network adapter is recognized in Device Manager.

    Replace the Ethernet cable if faulty. Reconfigure the IP address settings to match the network. Reinstall the network adapter driver if it is not recognized, or replace the Ethernet card if hardware failure is confirmed.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart