Siemens 6AV7612-0AB12-0BJ0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AB12-0BJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, enabling advanced process visualization, data acquisition, and control functions.
The SIMATIC Panel PC 670 6AV7612-0AB12-0BJ0 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch technology for operator input. It is built around an x86-compatible processor platform and supports standard PC operating systems such as Windows XP Professional or Windows XP Embedded. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232), and is designed for panel mounting with an IP65-rated front face for protection against dust and water ingress. Expansion slots allow for additional interface cards, and the unit supports standard PC memory configurations.
The SIMATIC Panel PC 670 is widely used in the manufacturing, automotive, food and beverage, and chemical processing industries. It is suited for applications requiring a full PC environment at the machine level, such as SCADA visualization, recipe management, quality data logging, and integration with Siemens SIMATIC WinCC or other SCADA software packages. Its robust industrial design and panel-mount form factor make it appropriate for installation directly on control cabinets and machine panels in factory floor environments.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT Color LCD |
| Touch Technology | Resistive Touch |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interfaces | Ethernet (RJ45), USB, RS-232 |
| Mounting | Panel mounting |
| Operating System Support | Windows XP Professional, Windows XP Embedded |
| Series | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat storage media. Replace storage device if faulty. - Event ID: 200
- Fan failure or thermal management warning indicating insufficient cooling.
Inspect and clean cooling fan and ventilation slots. Replace fan unit if not operating. Ensure ambient temperature is within specification. - Event ID: 300
- Watchdog timeout triggered due to application or OS hang.
Restart the Panel PC. Investigate software application for memory leaks or infinite loops. Update or reinstall the HMI application software. - Event ID: 400
- Ethernet communication loss or network interface not detected.
Check Ethernet cable and network switch connection. Verify IP address configuration in the operating system. Replace Ethernet cable or check network interface card. - Event ID: 500
- Touch screen calibration error or touch input not responding correctly.
Recalibrate the touch screen using the calibration utility in the operating system control panel. If unresponsive, check touch controller ribbon cable connection internally. - Event ID: 600
- Power supply undervoltage detected on 24 V DC input.
Measure the 24 V DC supply voltage at the input connector. Ensure supply voltage is within the 20.4 V to 28.8 V DC tolerance range. Replace or adjust the power supply unit. - Event ID: 700
- Hard disk or storage media read/write error detected.
Run a disk check utility (chkdsk) from the operating system. Back up data immediately and replace the hard disk or CompactFlash storage module if errors persist.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AB12-0BJ0?
The unit operates on a 24 V DC supply voltage, with a typical tolerance range of 20.4 V to 28.8 V DC.
What operating system does the SIMATIC Panel PC 670 6AV7612-0AB12-0BJ0 support?
This Panel PC supports Windows XP Professional and Windows XP Embedded as its operating systems, allowing standard PC software and Siemens WinCC to be installed.
What is the display size and resolution of this Panel PC?
The unit features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch input.
Is the front panel of the 6AV7612-0AB12-0BJ0 protected against dust and water?
Yes, the front face of the Panel PC 670 carries an IP65 protection rating, making it suitable for environments where dust and water spray may be present.
Can this Panel PC run Siemens WinCC SCADA software?
Yes, the SIMATIC Panel PC 670 is compatible with Siemens SIMATIC WinCC and other standard PC-based HMI and SCADA software packages, as it runs a full Windows operating system.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the input connector using a multimeter. Verify that the power LED indicator is active. Inspect internal fuse and backlight inverter board.
Ensure the 24 V DC supply is within tolerance. Replace the backlight inverter or CCFL backlight lamp if the display remains dark but the system is otherwise operational. Replace the internal power supply if no voltage is present.
Touch screen does not respond or registers incorrect touch positions
Attempt to recalibrate the touch screen via the Windows control panel calibration utility. Check for physical damage or contamination on the touch surface.
Perform a full touch screen recalibration. Clean the touch surface with a soft, dry cloth. If the issue persists, inspect the internal touch controller ribbon cable connection and replace the touch screen assembly if necessary.
Panel PC fails to boot or hangs during startup
Observe the boot sequence on the display. Check if the BIOS POST completes. Listen for hard disk activity. Connect an external keyboard and monitor if possible to diagnose further.
Reseat the CompactFlash card or hard disk. Restore the operating system image from a backup. If the BIOS does not complete POST, check RAM modules and reseat them. Replace the storage device if it is found to be faulty.
Ethernet communication is not established with the PLC or network
Verify the Ethernet cable connection and check the link LED on the RJ45 port. Confirm IP address settings in Windows Network Connections. Test with a known-good cable.
Replace the Ethernet cable. Reconfigure the IP address settings to match the network subnet. If the network interface is not detected by the OS, update the network adapter driver or replace the Ethernet interface card.
System overheats and shuts down unexpectedly
Check the ambient temperature around the Panel PC installation. Inspect the cooling fan for operation and the ventilation slots for blockage. Monitor CPU temperature using a system monitoring utility.
Clean all ventilation slots and the cooling fan with compressed air. Ensure the installation environment does not exceed 45 °C ambient temperature. Replace the cooling fan if it is not spinning. Verify that the panel cutout provides adequate clearance for airflow.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page