Siemens 6AV7612-0AB10-0CH0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AB10-0CH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface applications, combining a built-in display with a full PC architecture running a Windows-based operating system. This unit is intended for use as an operator station in industrial environments where both visualization and computing power are required.
The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and is equipped with a touch screen interface for intuitive operator interaction. It is built around an industrial-grade processor with integrated memory and supports multiple communication interfaces including Ethernet (RJ45) and serial ports, enabling connectivity to PLCs, SCADA systems, and plant networks. The unit operates on a 24 V DC supply and is designed to meet industrial EMC and safety standards, with a front panel protection rating of IP65 for resistance to dust and water ingress.
The SIMATIC Panel PC 670 is widely deployed in manufacturing, process automation, and machine tool industries where a robust, panel-mounted computing solution is required. Its compatibility with Siemens WinCC and other SCADA/HMI software makes it suitable for integration into SIMATIC automation architectures. The fanless or low-maintenance design options make it appropriate for environments where reliability and reduced maintenance intervals are critical.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touch screen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet (RJ45), RS-232, RS-422/485 |
| Operating System | Windows XP Embedded / Windows 2000 |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST.
Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat storage media. Replace storage device if faulty. - Event ID: 200
- Watchdog timeout triggered — application software stopped responding.
Restart the application software. Check for software conflicts or memory leaks. Update or reinstall the HMI runtime software. - Event ID: 300
- Ethernet communication link failure — network connection lost.
Check Ethernet cable and switch/hub connection. Verify IP address configuration. Test with a known-good cable. - Event ID: 400
- Touch screen calibration error — touch input not responding correctly.
Recalibrate the touch screen via the Windows control panel or SIMATIC configuration tool. Clean the touch surface and check for physical damage. - Event ID: 500
- Power supply undervoltage — supply voltage dropped below the minimum threshold.
Measure the 24 V DC supply at the input connector. Ensure the power supply unit can deliver sufficient current. Check wiring for voltage drop. - Event ID: 600
- Fan failure or overtemperature warning — internal temperature exceeded safe operating limits.
Check ambient temperature and ensure adequate ventilation around the panel. Clean air vents. Replace the cooling fan if faulty. - Event ID: 700
- Hard disk or storage media error — read/write failure on the system drive.
Run a disk check utility. Back up data immediately. Replace the hard disk or CompactFlash card if errors persist.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AB10-0CH0?
The unit operates on a 24 V DC supply voltage, which is standard for SIMATIC Panel PC 670 devices.
What is the display size and resolution of this Panel PC?
The 6AV7612-0AB10-0CH0 features a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA).
What HMI software is compatible with this Panel PC?
The SIMATIC Panel PC 670 is compatible with Siemens WinCC, WinCC flexible, and other Windows-based SCADA and HMI runtime software packages.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AB10-0CH0 carries an IP65 protection rating, making it resistant to dust and water jets.
Can this Panel PC communicate with Siemens S7 PLCs?
Yes, the unit supports Ethernet and serial communication interfaces and can connect to SIMATIC S7-300 and S7-400 PLCs using standard Siemens communication drivers and protocols such as PROFIBUS or Industrial Ethernet.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the input connector. Verify the power LED status. Measure voltage at the internal power supply output rails.
Ensure the 24 V DC supply is within tolerance. Replace the internal power supply board if no output voltage is present. Check and reseat display cable connections internally.
Touch screen does not respond or responds inaccurately
Attempt to operate the unit using a connected USB mouse or keyboard to determine if the issue is isolated to the touch screen. Check Device Manager for touch controller errors.
Recalibrate the touch screen using the Windows calibration utility. If calibration fails, check the touch controller ribbon cable connection. Replace the touch screen assembly if the controller is faulty.
Unit fails to boot or continuously restarts
Observe the boot sequence for POST error messages. Check the hard disk or CompactFlash card for errors using a bootable diagnostic tool.
Replace the storage media with a new hard disk or CompactFlash card and restore the operating system image. Verify BIOS settings are correct for the installed storage device.
Ethernet communication is not established
Check the Ethernet port LED indicators for link activity. Verify IP address settings in Windows network configuration. Test connectivity with a ping command.
Replace the Ethernet cable and verify switch port configuration. If the port LEDs do not illuminate with a known-good cable, the onboard NIC may be faulty and require board-level repair or replacement.
Unit overheats and shuts down unexpectedly
Monitor the internal temperature via BIOS or system monitoring software. Check that ambient temperature is within the 0 to 50 degrees C operating range. Inspect ventilation openings for blockage.
Improve cabinet ventilation or add active cooling. Clean dust from air vents and heat sinks. Replace the internal cooling fan if it is not operating correctly.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page