Siemens 6AV7612-0AB10-0BF0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AB10-0BF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. This unit combines a built-in display with a full PC architecture, enabling it to run standard Windows-based SCADA and HMI software alongside process control applications.
The SIMATIC Panel PC 670 features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen input for operator interaction. It is built around an industrial-grade processor platform and includes interfaces such as USB, serial (RS-232), and Ethernet for connectivity to PLCs, field devices, and plant networks. The unit is designed for front-panel mounting with an IP65 protection rating on the front face, making it resistant to dust and water ingress in industrial settings. It supports operation with Siemens WinCC and SIMATIC software environments.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a robust, panel-integrated PC solution is required. Its compatibility with standard Windows operating systems and Siemens SIMATIC software makes it suitable for integration into existing Siemens automation architectures. Typical deployment environments include automotive production lines, chemical processing plants, and packaging machinery where reliable visualization and operator control are essential.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet (RJ45), RS-232, USB |
| Mounting | Panel mounting (front flush) |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
| Operating System Support | Windows XP Professional / Windows 2000 |
Common Error Codes & System Events
- Event ID: 1000
- Application error — a software application has encountered an unexpected fault and terminated.
Check Windows Event Viewer for details. Reinstall or update the affected HMI application (e.g., WinCC). Verify software compatibility with the installed OS version. - Event ID: 7026
- Boot-start or system-start driver failed to load during Windows startup.
Check Device Manager for driver conflicts. Reinstall the relevant hardware driver. Verify hardware integrity of expansion cards or connected peripherals. - BIOS POST Error
- Hardware component not detected or failed during Power-On Self-Test.
Reseat RAM modules and expansion cards. Check all internal connectors. If the error persists, replace the faulty hardware component identified in the POST message. - Watchdog Timeout
- The system watchdog timer has expired, indicating the operating system or application has become unresponsive.
Investigate CPU load and running processes. Check for software loops or memory leaks in the HMI application. Adjust watchdog timeout settings or resolve the application fault. - Fan Failure Warning
- The system cooling fan has stopped or is operating below the minimum speed threshold.
Clean or replace the cooling fan. Ensure ventilation clearances around the panel PC are maintained. Check fan connector and power supply to the fan. - Hard Disk Error
- The internal hard disk or Compact Flash storage device has reported a read/write error or is not detected.
Run a disk diagnostic utility. Back up data immediately. Replace the hard disk or Compact Flash card with a compatible unit and restore the system image. - Temperature Warning
- Internal system temperature has exceeded the safe operating threshold.
Check ambient temperature around the panel PC. Clean air vents and filters. Verify cooling fan operation. Reduce thermal load or improve cabinet ventilation.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AB10-0BF0?
The SIMATIC Panel PC 670 (6AV7612-0AB10-0BF0) operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.
What display size and resolution does this Panel PC have?
This unit features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA), suitable for detailed process visualization.
Is the 6AV7612-0AB10-0BF0 compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is designed to run Siemens WinCC and other SIMATIC HMI software packages under Windows XP Professional or Windows 2000.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AB10-0BF0 carries an IP65 protection rating, providing full dust protection and resistance to water jets.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), RS-232 serial, and USB interfaces, enabling connectivity to PLCs, network infrastructure, and peripheral devices.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector. Verify the internal fuse and backlight inverter board. Confirm the display cable connection between the mainboard and the LCD panel.
Replace the blown fuse if found faulty. If the backlight inverter is defective, replace the inverter board or the complete display assembly. Ensure the 24 V DC supply is stable and within tolerance.
Touchscreen input is unresponsive or inaccurate
Check if the touchscreen controller is recognized in Device Manager. Determine whether the issue is a calibration problem or a hardware fault by testing with a mouse.
Recalibrate the touchscreen using the Windows calibration utility. If calibration does not resolve the issue, check the touchscreen ribbon cable connection. Replace the touchscreen overlay if the controller or surface is damaged.
Panel PC fails to boot and displays a BIOS error or stops at POST
Identify the POST error code or beep code displayed. Check RAM seating, hard disk connection, and BIOS battery voltage. Verify that the CMOS battery is not depleted.
Reseat RAM modules and storage devices. Replace the CMOS battery (typically CR2032) if BIOS settings are lost on power cycle. If the hard disk is not detected, replace it and restore the system image.
System freezes or reboots unexpectedly during operation
Check Windows Event Viewer for critical errors or watchdog events. Monitor CPU temperature and system resource usage. Inspect the hard disk for errors using diagnostic tools.
Address any overheating by cleaning fans and vents. Repair or replace a failing hard disk. If software-related, update or reinstall the HMI application and check for memory leaks or conflicting drivers.
Ethernet communication is lost or not established
Check the Ethernet cable and switch port. Verify IP address configuration in Windows Network Settings. Check Device Manager for network adapter status.
Replace the Ethernet cable if damaged. Reconfigure the IP address settings to match the network. Reinstall the network adapter driver if the adapter is shown with an error in Device Manager.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page