• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AA30-0CH0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AA30-0CH0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AA30-0CH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AA30-0CH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates computing hardware and a display into a single rugged enclosure suitable for direct panel mounting.

    The SIMATIC Panel PC 670 features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs Microsoft Windows XP Professional or Windows XP Embedded as its operating system. The unit provides standard PC interfaces including USB, Ethernet (RJ45), serial COM ports, and a parallel port, enabling integration with a wide range of peripheral devices and industrial networks. The front panel meets IP65 protection rating, making it resistant to dust and water ingress from the front.

    The SIMATIC Panel PC 670 is widely used in manufacturing, automotive, food and beverage, and process industries where a full PC-based HMI platform is required. It is suitable for applications demanding complex visualization, data logging, recipe management, and SCADA functionality at the machine level. Its robust industrial design and compatibility with Siemens WinCC and other SCADA software make it a practical choice for both standalone and networked control system architectures.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 pixels (XGA)
    Display Type TFT color LCD
    Touch Technology Resistive touch screen
    Processor Intel Celeron
    Operating System Windows XP Professional / Windows XP Embedded
    Input/Operating Voltage 24 V DC
    IP/Protection Rating IP65 (front panel)
    Communication Interface Ethernet RJ45, USB, RS-232 (COM), Parallel port
    Mounting Panel mounting
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    System startup error — the Panel PC failed to complete the boot sequence correctly, often due to a corrupted OS installation or failed hardware component.
    Check the boot device and OS integrity. Re-image the CompactFlash card or hard drive with the correct OS image. Verify RAM seating.
    Event ID: 200
    Watchdog timeout — the system watchdog timer was triggered, indicating the application or OS became unresponsive.
    Investigate the running application for deadlocks or excessive CPU load. Check for OS updates or application patches. Restart the Panel PC and monitor system performance.
    Event ID: 300
    Fan failure — the internal cooling fan has stopped or is operating below the required speed threshold.
    Inspect and clean the fan. Replace the fan unit if it is defective. Ensure ventilation clearances around the unit are maintained.
    Event ID: 400
    Temperature warning — the internal temperature of the Panel PC has exceeded the defined threshold.
    Check ambient temperature and ensure it is within the 0–50 °C operating range. Clean air filters and ventilation openings. Verify fan operation.
    Event ID: 500
    Hard disk or storage media error — read/write errors detected on the internal storage device.
    Run a disk diagnostic utility. Back up data immediately. Replace the CompactFlash card or hard drive as appropriate.
    Event ID: 600
    Network communication error — loss of Ethernet communication with the connected controller or network.
    Check Ethernet cable connections and switch/hub status. Verify IP address configuration and network settings in Windows. Check for driver issues in Device Manager.
    Event ID: 700
    Touch screen calibration error — the touch screen is not responding correctly or is misaligned.
    Run the touch screen calibration utility from the Windows control panel. If calibration fails repeatedly, inspect the touch screen controller hardware and connections.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7612-0AA30-0CH0?

    The SIMATIC Panel PC 670 (6AV7612-0AA30-0CH0) operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.

    What operating system does this Panel PC run?

    This unit supports Microsoft Windows XP Professional or Windows XP Embedded as its operating system.

    What is the IP protection rating of this Panel PC?

    The front panel of the 6AV7612-0AA30-0CH0 carries an IP65 protection rating, providing full dust protection and resistance to water jets. The rear of the unit is not rated to IP65.

    Is this Panel PC compatible with Siemens WinCC?

    Yes, the SIMATIC Panel PC 670 is compatible with Siemens WinCC and other PC-based HMI and SCADA software packages, as it runs a standard Windows operating system.

    What communication interfaces are available on this unit?

    The 6AV7612-0AA30-0CH0 provides Ethernet (RJ45), USB ports, RS-232 serial COM ports, and a parallel port for connecting to peripherals and industrial networks.

    Troubleshooting

    Panel PC does not power on after 24 V DC is applied

    Measure the 24 V DC supply voltage at the power connector to confirm correct voltage level. Check the internal fuse and power supply module.

    Replace any blown internal fuse with the correct rating. If the power supply module is faulty, replace it. Ensure the 24 V DC source is stable and within tolerance.

    Display remains blank after power on but the PC appears to boot

    Check if the backlight is functioning by shining a light at the screen to see if an image is faintly visible. Verify display cable connections internally.

    Replace the backlight inverter or the TFT display panel if the backlight has failed. Re-seat internal display ribbon cables if they have become loose.

    Touch screen does not respond or responds inaccurately

    Attempt to recalibrate the touch screen using the Windows calibration utility. Check Device Manager for touch screen controller errors.

    Recalibrate the touch screen. If the issue persists, inspect the touch screen overlay and controller board connections. Replace the touch screen overlay if it is physically damaged.

    Panel PC freezes or reboots unexpectedly during operation

    Check the internal temperature using the BIOS or system monitoring software. Review Windows Event Viewer for application or system errors. Check CPU and RAM utilization.

    Clean internal ventilation paths and verify fan operation to prevent overheating. Reduce application load if CPU usage is consistently high. Re-image the OS if software corruption is suspected.

    Ethernet communication is lost intermittently

    Check the Ethernet cable and connector for physical damage. Verify network settings including IP address, subnet mask, and gateway in Windows Network Connections.

    Replace the Ethernet cable if damaged. Update the network adapter driver. If the onboard Ethernet port is faulty, install a USB-to-Ethernet adapter as a temporary measure and arrange for board-level repair.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart