• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AA22-0BH0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AA22-0BH0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AA22-0BH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AA22-0BH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, offering a compact and integrated solution for process visualization and control.

    The SIMATIC Panel PC 670 (6AV7612-0AA22-0BH0) features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and a resistive touchscreen interface. It is based on an x86-compatible processor architecture and runs Microsoft Windows operating systems, supporting SIMATIC WinCC and other SCADA/HMI software packages. The unit provides standard PC interfaces including USB ports, serial COM ports, and an Ethernet interface for network connectivity, along with expansion slots for additional hardware modules. The enclosure is designed for front-panel mounting with an IP65 protection rating on the front face, making it suitable for use in environments where dust and water ingress are a concern.

    The SIMATIC Panel PC 670 is widely used in manufacturing, automotive, food and beverage, and process industries where a full PC-based HMI platform is required. It is particularly suited for applications demanding complex visualization, data logging, recipe management, and integration with enterprise-level systems via standard Ethernet networks. Its panel-mount form factor allows direct integration into control cabinet doors and operator stations on the production floor.

    Technical Specifications

    Display Size 12.1 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT LCD
    Display Colors 256,000 colors
    Touch Technology Resistive touchscreen
    Input/Operating Voltage 24 V DC
    IP/Protection Rating IP65 (front), IP20 (rear)
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Communication Interface Ethernet (RJ45), USB, RS-232 (COM ports)
    Mounting Panel mounting (front-panel flush mount)
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    Operating system startup error or boot failure detected during POST sequence.
    Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat storage media. Replace storage device if faulty.
    Event ID: 200
    Hardware watchdog timeout — the system did not respond within the watchdog monitoring interval.
    Check CPU load and running processes. Ensure the WinCC or HMI application is not hanging. Restart the panel and investigate software causing high CPU utilization.
    Event ID: 300
    Fan failure or thermal warning — internal cooling fan has stopped or temperature threshold exceeded.
    Inspect and clean the cooling fan and ventilation slots. Replace the fan if defective. Ensure ambient temperature is within the specified operating range.
    Event ID: 400
    UPS (uninterruptible power supply) module fault or battery low condition detected.
    Check the UPS module connection and battery charge level. Replace the UPS battery if depleted. Verify 24 V DC supply voltage is within tolerance.
    Event ID: 500
    Ethernet communication error — loss of network connection or network interface fault.
    Check Ethernet cable and switch/hub connection. Verify IP address configuration. Inspect the RJ45 port for physical damage and replace network cable if necessary.
    Event ID: 600
    Touch screen calibration error or touch input not responding correctly.
    Recalibrate the touchscreen using the Windows calibration utility or SIMATIC panel configuration tool. Clean the screen surface. If unresponsive, check touchscreen controller connection internally.
    Event ID: 700
    Application software crash or WinCC runtime error detected.
    Restart the HMI application. Check WinCC project configuration for errors. Review Windows Event Viewer logs for application faults and reinstall the runtime software if necessary.

    Frequently Asked Questions

    What operating system does the SIMATIC Panel PC 670 (6AV7612-0AA22-0BH0) support?

    The SIMATIC Panel PC 670 is designed to run Microsoft Windows operating systems, typically Windows XP Professional or Windows 2000, and supports SIMATIC WinCC and other Siemens HMI software packages.

    What is the display size and resolution of this panel PC?

    The 6AV7612-0AA22-0BH0 features a 12.1-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and a resistive touchscreen.

    What is the supply voltage for this unit?

    The SIMATIC Panel PC 670 operates on a 24 V DC supply voltage.

    Is this panel PC compatible with SIMATIC WinCC?

    Yes, the SIMATIC Panel PC 670 is fully compatible with SIMATIC WinCC and other Siemens visualization software, making it a standard platform for Siemens-based HMI applications.

    What is the front panel protection rating of the 6AV7612-0AA22-0BH0?

    The front panel of the 6AV7612-0AA22-0BH0 carries an IP65 protection rating, providing protection against dust and low-pressure water jets when correctly installed in a panel cutout.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the power input connector. Check the internal fuse and verify the power LED status. Connect an external monitor via VGA port if available to determine if the issue is display-specific.

    Replace the internal fuse if blown. If the supply voltage is correct and the external monitor shows output, the TFT display or its backlight inverter may be faulty and should be replaced. If no output is detected at all, the main board or power supply module may require replacement.

    Touchscreen does not respond or registers incorrect touch positions

    Verify that the touchscreen surface is clean and free of contaminants. Access the Windows calibration tool to check if calibration data is corrupted. Check Device Manager for touchscreen controller errors.

    Recalibrate the touchscreen using the Windows Tablet PC Settings or the SIMATIC panel calibration utility. If calibration fails repeatedly, inspect the internal touchscreen controller ribbon cable connection. Replace the touchscreen assembly if the controller is defective.

    Panel PC fails to boot or repeatedly restarts

    Observe the POST (power-on self-test) messages on screen. Check the CompactFlash card or hard disk for errors using a bootable diagnostic tool. Inspect the BIOS settings for correct boot device order.

    Reseat the CompactFlash card or hard disk. Run a disk integrity check and restore the operating system image from a backup if the storage media is corrupted. Replace the storage device if hardware failure is confirmed.

    Ethernet communication is lost or intermittent

    Check the Ethernet cable and verify the link LED on the RJ45 port is active. Ping the panel from a network device to test connectivity. Review IP address and subnet mask settings in Windows Network Connections.

    Replace the Ethernet cable if damaged. Reconfigure the IP settings if incorrect. If the link LED is absent with a known-good cable, the onboard network interface card may be faulty and require replacement or an expansion card substitute.

    WinCC runtime application crashes or freezes

    Review the Windows Event Viewer application and system logs for error entries at the time of the crash. Check available RAM and disk space. Verify that the WinCC project version is compatible with the installed runtime version.

    Free up disk space and close unnecessary background applications. Reinstall the WinCC runtime software if files are corrupted. Update the WinCC project to match the installed runtime version and apply any available Siemens service packs or patches.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart