Siemens 6AV7612-0AA20-0CJ0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AA20-0CJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a flat-panel display with a full PC architecture, providing both operator interface and computing functionality in a single compact device.
The SIMATIC Panel PC 670 (6AV7612-0AA20-0CJ0) features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA). It is equipped with an Intel Celeron processor and runs Microsoft Windows XP Professional or Windows 2000, supporting SIMATIC WinCC and other SCADA/HMI software packages. The unit provides standard PC interfaces including USB, serial (RS-232), parallel, and Ethernet (RJ45), and supports expansion via PCI slots. It is built to IP65 protection rating on the front panel, making it suitable for use in environments where dust and water ingress are a concern.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building industries where a robust, panel-mounted PC-based HMI solution is required. It is commonly deployed in applications such as production line visualization, SCADA workstations, and machine control panels. Its fanless or low-noise design options and industrial-grade components make it suitable for continuous operation in factory floor environments.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Type | TFT Color LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| IP Protection Rating (Front) | IP65 |
| Operating System | Windows XP Professional / Windows 2000 |
| Communication Interface | Ethernet (RJ45), RS-232 (COM), USB, Parallel (LPT) |
| Input Voltage | 24 V DC |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 95% (non-condensing) |
| Mounting | Panel mounting |
| Series | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes and System Events
- Event ID: 1000
- Application error in the operating system or HMI runtime software, typically logged in the Windows Event Viewer.
Check the Windows Event Viewer for detailed error information. Reinstall or repair the affected HMI runtime application (e.g., WinCC) if necessary. - Event ID: 7026
- A boot-start or system-start driver failed to load during Windows startup.
Check Device Manager for driver conflicts. Reinstall the appropriate hardware driver or restore the system using a backup image. - BIOS POST Error
- Hardware component not detected or failed during Power-On Self-Test, preventing normal boot.
Check all internal connections including RAM and storage device. Reseat or replace the faulty component identified during POST. - WinCC Runtime Error
- SIMATIC WinCC runtime fails to start or crashes, often due to corrupted project files or licensing issues.
Verify the WinCC license is valid and installed correctly. Restore the project from a backup or reinstall the WinCC runtime software. - Network Communication Fault
- Loss of Ethernet communication between the Panel PC and the PLC or SCADA server.
Check Ethernet cable and switch connections. Verify IP address configuration and ensure the PLC or server is reachable via ping. - Watchdog Timeout
- The system watchdog timer has triggered due to a software hang or unresponsive application.
Perform a controlled restart of the Panel PC. Investigate the application causing the hang and update or reconfigure it to prevent recurrence. - Storage Device Error
- The internal hard disk or CompactFlash storage device is failing or not detected.
Check the storage device connection. Replace the hard disk or CompactFlash card and restore the system image from a backup.
Frequently Asked Questions
What is the display size and resolution of the 6AV7612-0AA20-0CJ0?
The 6AV7612-0AA20-0CJ0 features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA).
What operating systems are supported by this Panel PC?
This unit supports Microsoft Windows XP Professional and Windows 2000, and is compatible with SIMATIC WinCC and other Siemens HMI software packages.
What is the supply voltage for the SIMATIC Panel PC 670?
The Panel PC 670 operates on a 24 V DC supply voltage, which is standard for industrial panel-mounted devices.
What communication interfaces are available on this unit?
The 6AV7612-0AA20-0CJ0 provides Ethernet (RJ45), RS-232 serial, USB, and parallel (LPT) interfaces for connectivity to PLCs, networks, and peripherals.
What is the front panel protection rating of this Panel PC?
The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, providing protection against dust ingress and low-pressure water jets.
Troubleshooting
Panel PC does not boot and display remains blank after power on
Check the 24 V DC supply voltage at the power input connector. Verify the internal fuse and inspect the power supply board for visible damage.
Restore the correct 24 V DC supply. Replace the internal fuse if blown. If the power supply board is faulty, replace it or send the unit for repair.
Touchscreen does not respond to input
Check if the touchscreen controller is recognized in Windows Device Manager. Inspect the touchscreen ribbon cable connection to the controller board.
Recalibrate the touchscreen using the Windows control panel utility. If the controller is not detected, reseat the ribbon cable or replace the touchscreen controller board.
HMI runtime software (WinCC) fails to start after Windows boot
Check the Windows Event Viewer for application errors. Verify that the WinCC license dongle or software license is present and valid.
Reinstall or repair the WinCC runtime installation. Restore the project files from a backup if they are corrupted. Ensure the license is correctly activated.
Ethernet communication to PLC is lost intermittently
Inspect the Ethernet cable and RJ45 connector for damage. Check the network switch port and verify the IP configuration in Windows network settings.
Replace the Ethernet cable if damaged. Set a static IP address to avoid DHCP-related issues. Update the network adapter driver if necessary.
System runs slowly or freezes during operation
Check CPU and memory utilization in Windows Task Manager. Inspect the hard disk or CompactFlash card for errors using disk diagnostic tools.
Close unnecessary background applications. Replace the hard disk or CompactFlash card if errors are detected. Consider upgrading RAM if the system is running near its memory limit.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page