Siemens 6AV7612-0AA12-0AE0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AA12-0AE0 is an industrial Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is a compact, panel-mounted industrial computing platform designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a flat-panel display with a full PC architecture, enabling advanced process visualization, data acquisition, and operator control functions.
The SIMATIC Panel PC 670 (6AV7612-0AA12-0AE0) features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch screen technology for reliable operator input. It is built around an x86-compatible processor architecture and supports standard PC interfaces including USB, serial (RS-232), and Ethernet (RJ45) for integration with plant networks and Siemens SIMATIC controllers. The unit operates on a 24 V DC supply and is designed for front-panel mounting with an IP65 protection rating on the front face, making it suitable for use in environments where dust and water ingress are a concern. It supports Windows-based operating systems, enabling compatibility with Siemens WinCC and other SCADA/HMI software packages.
The SIMATIC Panel PC 670 is widely deployed in manufacturing, process industries, automotive production, and machine building applications where a full PC-based HMI platform is required. Its rugged construction and industrial-grade components make it appropriate for continuous operation in factory floor environments subject to vibration, temperature variation, and electromagnetic interference. The combination of standard PC connectivity and Siemens SIMATIC ecosystem compatibility makes it a practical choice for integration into both new installations and upgrades of existing automation systems.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT Color LCD |
| Display Colors | 262,144 colors |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM port) |
| Mounting | Panel mounting (front-panel flush mount) |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or Compact Flash card integrity. Verify OS installation. Replace storage medium if corrupted. - Event ID: 200
- Watchdog timeout triggered — the application software stopped responding within the defined watchdog interval.
Restart the Panel PC. Check the HMI/SCADA application for software hangs or infinite loops. Update or reinstall the application software. - Event ID: 300
- Fan failure or thermal warning — internal cooling fan has stopped or CPU temperature has exceeded threshold.
Inspect and clean the cooling fan. Replace the fan if defective. Ensure ambient temperature is within the specified operating range. - Event ID: 400
- Ethernet communication error — loss of network connection or failure to establish communication with the controller.
Check Ethernet cable and switch/hub connections. Verify IP address configuration. Check controller communication settings in WinCC or the HMI project. - Event ID: 500
- Touchscreen calibration error — touch input is misaligned or not responding correctly.
Perform touchscreen recalibration via the Windows Control Panel or SIMATIC HMI settings. If the issue persists, inspect the touch controller hardware. - Event ID: 600
- Power supply undervoltage — the 24 V DC supply voltage has dropped below the permissible operating threshold.
Measure the supply voltage at the power connector. Ensure the power supply unit provides a stable 24 V DC within the specified tolerance. Replace the power supply if necessary. - Event ID: 700
- Hard disk or storage medium error — read/write failure detected on the internal storage device.
Run a disk check utility. Back up data immediately. Replace the hard disk or Compact Flash card as required.
Frequently Asked Questions
What is the supply voltage for the 6AV7612-0AA12-0AE0?
The SIMATIC Panel PC 670 (6AV7612-0AA12-0AE0) operates on a 24 V DC supply voltage.
What display size and resolution does this Panel PC have?
This unit features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and a resistive touchscreen.
What operating system does the SIMATIC Panel PC 670 support?
The Panel PC 670 supports Windows-based operating systems (such as Windows XP Embedded or Windows 2000), enabling compatibility with Siemens WinCC and other industrial HMI/SCADA software.
What is the front panel protection rating of this unit?
The front panel of the 6AV7612-0AA12-0AE0 carries an IP65 protection rating, providing protection against dust ingress and low-pressure water jets.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), USB ports, and RS-232 serial (COM) interfaces for connectivity to plant networks, Siemens SIMATIC controllers, and peripheral devices.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector using a multimeter. Inspect internal fuses and verify the backlight inverter is functioning.
Restore the supply voltage to within the specified 24 V DC range. Replace the backlight inverter or LCD panel if the display hardware is faulty. Check and replace any blown internal fuses.
Touchscreen input is unresponsive or inaccurate
Determine whether the issue is a calibration problem or a hardware fault by attempting recalibration. Check the touch controller connection to the mainboard.
Recalibrate the touchscreen via the Windows Control Panel or SIMATIC HMI calibration utility. If recalibration fails, inspect the touch controller ribbon cable connections and replace the touchscreen assembly if defective.
Panel PC fails to boot or repeatedly restarts
Observe POST messages on the display. Check the integrity of the storage medium (hard disk or Compact Flash card) and verify the OS installation is intact.
Replace the storage medium and reinstall the operating system and HMI application software. Ensure the BIOS settings are correctly configured for the installed hardware.
Loss of Ethernet communication with the PLC or network
Check the Ethernet cable, switch port, and LED link indicators on the RJ45 connector. Verify the IP address and subnet mask configuration in Windows network settings.
Replace the Ethernet cable if damaged. Reconfigure the IP address settings to match the plant network. Update the network adapter driver if communication issues persist after hardware checks.
Unit overheating or thermal shutdown
Check the ambient temperature around the Panel PC installation. Inspect the cooling fan for blockage or failure. Verify that ventilation clearances around the unit are maintained.
Clean dust from the cooling fan and ventilation openings. Replace the cooling fan if it has failed. Ensure the installation environment does not exceed the maximum operating temperature of 45 °C.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page