• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7612-0AA10-0CE0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7612-0AA10-0CE0 SIMATIC Panel PC 670

    € 2.007,00

    Reset
    Clear
    SKU: 6AV7612-0AA10-0CE0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7612-0AA10-0CE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, enabling it to run standard Windows-based SCADA and HMI software alongside process control applications.

    The SIMATIC Panel PC 670 (6AV7612-0AA10-0CE0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and is equipped with a touch-sensitive screen for operator interaction. It is powered by an industrial-grade processor and supports standard PC interfaces including USB, serial (RS-232), and Ethernet (RJ45) for integration into plant networks and PLC communication. The unit is designed for front-panel mounting with an IP65 protection rating on the front face, making it resistant to dust and water ingress in industrial environments. It operates on a 24 V DC supply and is built to withstand the vibration, temperature, and EMC requirements typical of industrial automation settings.

    The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building industries where a full PC-based HMI solution is required. It is suitable for applications such as production line visualization, batch control, and data acquisition in sectors including automotive, food and beverage, chemical processing, and packaging. Its compatibility with Siemens WinCC and other standard HMI software packages makes it a practical choice for integration into existing Siemens automation architectures.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT color LCD
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    IP Protection Rating (Front) IP65
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Communication Interface Ethernet (RJ45), RS-232, USB
    Mounting Front panel mounting
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL
    Operating System Windows XP Embedded / Windows 2000

    Common Error Codes & System Events

    Event ID: 1000
    Application error — a software process on the Panel PC has terminated unexpectedly.
    Check Windows Event Viewer for details. Reinstall or update the affected HMI application. Verify sufficient RAM and storage are available.
    Event ID: 7034
    A service terminated unexpectedly, typically related to the HMI runtime or communication service.
    Restart the affected Windows service via Service Manager. If recurring, check for software corruption and reinstall the runtime software.
    BIOS POST Error
    Hardware self-test failure during power-on, indicating a memory, CPU, or hardware component fault.
    Reseat RAM modules and internal connectors. If the error persists, identify the failing component via BIOS beep codes and replace the defective hardware.
    WinCC Runtime Error
    WinCC or ProTool runtime fails to start or crashes, often due to a corrupted project file or license issue.
    Verify the WinCC license dongle or software license is present and valid. Reload the project file from backup and restart the runtime.
    Communication Timeout
    Loss of communication between the Panel PC and the connected PLC or controller, resulting in a timeout alarm on the HMI.
    Check Ethernet or serial cable connections. Verify PLC IP address and communication parameters in the HMI project configuration. Check network switch status.
    Watchdog Timeout
    The system watchdog has triggered a reset due to the operating system or application becoming unresponsive.
    Investigate CPU load and running processes. Reduce background tasks, update drivers, or replace hardware if the processor or memory is faulty.
    Hard Disk Error
    The internal storage device (HDD or CompactFlash) has reported a read/write error or is failing.
    Back up all data immediately. Run a disk diagnostic utility. Replace the internal storage medium and restore the operating system and project from backup.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7612-0AA10-0CE0?

    The SIMATIC Panel PC 670 (6AV7612-0AA10-0CE0) operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel devices.

    What is the display size and resolution of this Panel PC?

    This unit features a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA), suitable for detailed process visualization.

    What HMI software is compatible with this Panel PC?

    The 6AV7612-0AA10-0CE0 is compatible with Siemens WinCC, ProTool/Pro, and other standard Windows-based SCADA and HMI software packages that support Windows XP Embedded or Windows 2000.

    What is the front panel protection rating of this unit?

    The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, providing full protection against dust ingress and resistance to water jets.

    What communication interfaces are available on this Panel PC?

    The unit provides Ethernet (RJ45), RS-232 serial, and USB interfaces, enabling connectivity to PLCs, plant networks, and peripheral devices.

    Troubleshooting

    Display remains blank after power on

    Check that 24 V DC is present at the power supply connector. Measure voltage at the internal power supply output. Inspect the display backlight and internal fuse.

    Restore correct 24 V DC supply if absent. Replace the backlight inverter or display unit if the backlight has failed. Replace the internal fuse if blown.

    Touchscreen does not respond or is inaccurate

    Check for physical damage to the touch surface. Verify the touchscreen driver is installed correctly in Windows Device Manager. Attempt touchscreen recalibration via the control panel.

    Recalibrate the touchscreen using the Siemens or Windows calibration utility. If the touchscreen remains unresponsive, replace the touch overlay or the complete display assembly.

    Panel PC fails to boot into Windows

    Listen for BIOS beep codes during POST. Connect an external monitor to check if the display is the issue. Check the internal CompactFlash card or hard disk for errors using BIOS diagnostics.

    Reseat internal memory modules and storage media. If the storage device is corrupted, replace it and reinstall the operating system and HMI project from a backup image.

    Loss of communication with PLC

    Verify Ethernet or serial cable integrity and connections. Check the PLC IP address and communication settings in the HMI project. Use a network ping test to confirm connectivity.

    Replace faulty cables or connectors. Correct IP address or communication parameter mismatches in the HMI project configuration. Check and reset the network switch or router if required.

    HMI runtime software crashes repeatedly

    Check Windows Event Viewer for application error logs. Verify that the WinCC or ProTool license is valid and the dongle is present. Check available RAM and CPU usage during operation.

    Reinstall the HMI runtime software and reload the project from a known-good backup. Replace the license dongle if faulty. Upgrade RAM if system resources are insufficient.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart