Siemens 6AV7612-0AA10-0BH0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AA10-0BH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and rugged solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7612-0AA10-0BH0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs on a Windows-based operating system, providing compatibility with standard SCADA and HMI software packages including WinCC and WinCC flexible. The unit communicates via standard industrial interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), and is designed for panel mounting with a protection rating of IP65 on the front face.
The SIMATIC Panel PC 670 is widely used in the manufacturing, automotive, food and beverage, and chemical processing industries. It is typically deployed as a central visualization station on machine control panels, production lines, and process control cabinets where a robust, integrated PC-based HMI is required. Its compatibility with Siemens SIMATIC software and standard Windows applications makes it suitable for complex visualization tasks requiring custom graphics, data logging, and network connectivity.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Communication Interface | Ethernet (RJ45), USB, RS-232/RS-422/RS-485 |
| Operating System | Windows XP Embedded |
| Mounting | Panel mounting |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to initialize correctly during boot.
Check the CompactFlash card or hard disk for errors. Reformat or replace the storage medium and reinstall the operating system if necessary. - Event ID: 200
- Watchdog timeout — the application software did not respond within the expected time window.
Restart the Panel PC. Check the HMI application for software loops or resource overloads. Update or reinstall the HMI runtime software. - Event ID: 300
- Ethernet communication failure — loss of network connection detected.
Verify Ethernet cable connections and network switch status. Check IP address configuration and ensure the network adapter driver is functioning correctly. - Event ID: 400
- Touchscreen calibration error — touch input is misaligned or unresponsive.
Run the touchscreen calibration utility from the Windows control panel. If the issue persists, check the touchscreen controller connection or replace the touchscreen assembly. - Event ID: 500
- Power supply undervoltage — the 24 V DC supply voltage has dropped below the minimum operating threshold.
Measure the supply voltage at the power connector. Ensure the supply is within the 24 V DC nominal range and check for loose connections or an undersized power supply unit. - Event ID: 600
- Fan failure or overtemperature warning — internal temperature has exceeded the safe operating limit.
Check that ventilation slots are not blocked. Verify the cooling fan is operational. Ensure ambient temperature is within the 0 °C to +50 °C operating range. - Event ID: 700
- Storage medium error — read/write error detected on the CompactFlash card or hard disk.
Back up data immediately if possible. Replace the CompactFlash card or hard disk and reinstall the operating system and HMI application software.
Frequently Asked Questions
What operating system does the 6AV7612-0AA10-0BH0 run?
The SIMATIC Panel PC 670 (6AV7612-0AA10-0BH0) runs Windows XP Embedded, which provides compatibility with standard Siemens HMI software such as WinCC and WinCC flexible.
What is the supply voltage for this Panel PC?
The unit operates on a 24 V DC supply voltage, which is standard for Siemens SIMATIC panel-mounted devices.
What communication interfaces are available on this unit?
The 6AV7612-0AA10-0BH0 is equipped with Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), enabling connectivity to PLCs, networks, and peripheral devices.
What is the front panel protection rating of this device?
The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it suitable for environments where dust and water spray may be present.
Is this Panel PC compatible with Siemens WinCC software?
Yes, the SIMATIC Panel PC 670 is compatible with Siemens WinCC and WinCC flexible HMI software, which can be installed directly on the Windows-based operating system.
Troubleshooting
Display remains blank after power on
Check that the 24 V DC supply voltage is present at the power connector using a multimeter. Verify that the power LED indicator is illuminated. If voltage is correct but display is blank, the backlight or internal power supply may have failed.
Replace the backlight inverter or LCD backlight lamp if the unit powers on but the screen remains dark. If no power LED is present, check fuses and the 24 V DC supply unit.
Touchscreen does not respond or responds inaccurately
Attempt to operate the unit using an external USB mouse to determine if the issue is isolated to the touchscreen. Access the Windows control panel to check touchscreen driver status.
Recalibrate the touchscreen using the calibration utility in the Windows control panel. If calibration does not resolve the issue, check the internal touchscreen controller cable connections or replace the touchscreen assembly.
Unit fails to boot or repeatedly restarts
Check the CompactFlash card or hard disk for physical damage or loose seating. Attempt to boot from an external USB device to isolate whether the issue is with the storage medium or the motherboard.
Reseat or replace the CompactFlash card. Reinstall the operating system and HMI application software. If the unit still fails to boot, the motherboard or processor module may require replacement.
Ethernet communication is lost or intermittent
Check the Ethernet cable and connector for damage. Verify the network switch port is active. Use the Windows Device Manager to confirm the network adapter is recognized and drivers are loaded correctly.
Replace the Ethernet cable if damaged. Reconfigure the IP address settings if a network change has occurred. Update or reinstall the network adapter driver if the adapter is not recognized.
Overtemperature warning or unexpected shutdown due to heat
Check that the ventilation slots on the rear and sides of the Panel PC are not obstructed. Measure the ambient temperature in the control cabinet to confirm it is within the 0 °C to +50 °C operating range.
Clear any obstructions from ventilation slots. Install additional cabinet cooling if ambient temperature exceeds the rated limit. Clean dust from internal fans and heat sinks using compressed air.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page