Siemens 6AV7612-0AA10-0AG0 SIMATIC Panel PC 670
€ 2.007,00
The Siemens 6AV7612-0AA10-0AG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. This unit combines a flat-panel display with an integrated PC platform, providing a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7612-0AA10-0AG0) features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and a resistive touch screen interface. It is powered by an Intel Celeron processor and runs Microsoft Windows operating systems, supporting SIMATIC WinCC and other Siemens HMI software packages. The unit provides standard PC interfaces including USB, serial (RS-232), parallel, and Ethernet ports, enabling integration with a wide range of automation and control systems. The enclosure is rated IP65 at the front panel, protecting against dust and water ingress in industrial settings.
The SIMATIC Panel PC 670 is widely used in manufacturing, automotive, chemical processing, and food and beverage industries where a robust, panel-mounted PC with visualization capabilities is required. It is suitable for installation in control cabinets and operator panels on the factory floor, where reliable long-term operation under harsh environmental conditions is essential. Its compatibility with Siemens SIMATIC software makes it a natural fit for plants already using Siemens automation infrastructure.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT Color LCD |
| Display Colors | 256,000 colors |
| Touch Technology | Resistive touchscreen |
| Processor | Intel Celeron |
| Operating System | Microsoft Windows (XP/2000) |
| Front Panel Protection | IP65 |
| Input/Operating Voltage | 24 V DC |
| Communication Interface | Ethernet (RJ45), RS-232, USB, Parallel (LPT) |
| Mounting | Panel mounting (portrait/landscape) |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup error – the operating system failed to load correctly during boot.
Check the hard disk or CompactFlash card for errors. Verify OS integrity and re-image if necessary. - Event ID: 101
- Hardware initialization failure – a hardware component was not detected during POST.
Check all internal connections and seated components. Replace faulty RAM or storage media if identified. - Event ID: 200
- Touchscreen calibration error – the touch input is misaligned or unresponsive.
Re-run the touchscreen calibration utility from the Windows control panel. Clean the screen surface and check the touch controller connection. - Event ID: 300
- Ethernet communication failure – the network interface is not establishing a connection.
Check the Ethernet cable and switch port. Verify IP configuration settings in Windows network settings. - Event ID: 400
- Fan failure or overtemperature warning – internal temperature has exceeded the operating threshold.
Check that ventilation slots are unobstructed. Inspect and replace the internal cooling fan if it has stopped operating. - Event ID: 500
- Storage media error – read/write errors detected on the hard disk or CompactFlash card.
Run a disk check utility. Replace the storage media and restore the system image if errors cannot be corrected. - Event ID: 600
- Software watchdog timeout – the HMI application has stopped responding.
Restart the HMI application. Check for software conflicts or insufficient system resources and update or reinstall the HMI software.
Frequently Asked Questions
What display size and resolution does the 6AV7612-0AA10-0AG0 have?
This unit features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and a resistive touchscreen interface.
What is the supply voltage for the SIMATIC Panel PC 670 (6AV7612-0AA10-0AG0)?
The unit operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.
What HMI software is compatible with this Panel PC?
The 6AV7612-0AA10-0AG0 is compatible with Siemens SIMATIC WinCC and other Windows-based HMI and SCADA software packages, as it runs a standard Microsoft Windows operating system.
What is the front panel protection rating of this unit?
The front panel of the SIMATIC Panel PC 670 is rated IP65, providing protection against dust and low-pressure water jets.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), RS-232 serial, USB, and parallel (LPT) ports for connectivity to PLCs, networks, and peripheral devices.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify that the internal backlight inverter is functioning and that the display cable is securely connected.
Restore correct supply voltage if out of range. Replace the backlight inverter or LCD panel if the backlight has failed. Reseat the display cable connector.
Touchscreen does not respond or is inaccurate
Determine whether the issue is a calibration problem or a hardware failure by testing touch response in the Windows calibration utility.
Recalibrate the touchscreen using the Windows control panel calibration tool. If unresponsive after calibration, check the touch controller board connection or replace the touchscreen assembly.
Unit fails to boot or operating system does not load
Listen for POST beep codes and check BIOS output. Inspect the CompactFlash card or hard disk for physical damage or corruption.
Re-image the storage media with a valid system image. Replace the CompactFlash card or hard disk if the media is physically damaged or unreadable.
Ethernet communication not working
Check the link LED on the Ethernet port. Verify cable integrity and switch port status. Confirm IP address configuration in Windows network settings.
Replace the Ethernet cable if faulty. Reconfigure the IP settings to match the network. Update or reinstall the network adapter driver if the interface is not detected.
Unit overheating or shutting down unexpectedly
Check the ambient temperature around the unit and verify that all ventilation slots are clear. Inspect the internal cooling fan for operation.
Ensure the installation environment is within the 0 to 45 °C operating range. Clear any obstructions from ventilation slots and replace the internal fan if it has failed.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page