• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AF32-0CE0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AF32-0CE0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AF32-0CE0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AF32-0CE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a display, computing hardware, and industrial-grade I/O into a single compact panel-mount enclosure.

    The SIMATIC Panel PC 670 6AV7611-0AF32-0CE0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and is equipped with a touch screen interface for operator interaction. It runs on a standard x86-compatible processor platform and supports Microsoft Windows operating systems, enabling compatibility with SIMATIC WinCC and other SCADA or HMI software packages. The unit provides multiple communication interfaces including Ethernet (RJ45) and serial ports, and supports expansion via PCI slots. It is built to industrial standards with a fanless or low-noise cooling design suitable for continuous operation.

    The SIMATIC Panel PC 670 is widely deployed in manufacturing automation, process control, and machine tool applications where a robust, panel-mounted computing platform is required. Its compatibility with Siemens SIMATIC software and standard PC architecture makes it suitable for use in automotive production lines, food and beverage processing, and chemical plant control systems. The sealed front panel and industrial-grade construction allow reliable operation in environments with dust, vibration, and temperature variation.

    Technical Specifications

    Series SIMATIC Panel PC 670
    Display Size 12 inch
    Display Type TFT LCD
    Display Resolution 800 x 600 pixels (SVGA)
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    IP Rating (Front) IP65
    Mounting Panel mounting
    Communication Interface Ethernet (RJ45), RS-232, RS-422/485
    Operating System Windows XP / Windows 2000 compatible
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    System startup failure — the Panel PC fails to complete the boot sequence, often due to a corrupted OS or failed storage device.
    Check the hard disk or CompactFlash card for errors. Reinstall or restore the operating system image if necessary.
    Event ID: 200
    Touchscreen calibration error — the touch input is misaligned or unresponsive after startup.
    Run the touchscreen calibration utility from the Windows control panel or SIMATIC configuration tool. If unresponsive, check the touch controller cable connection internally.
    Event ID: 300
    Ethernet communication failure — the Panel PC cannot establish a network connection to the PLC or SCADA system.
    Verify Ethernet cable integrity and switch port status. Check IP address configuration and ensure the correct network driver is installed.
    Event ID: 400
    WinCC Runtime connection lost — the HMI application loses communication with the connected SIMATIC PLC.
    Check the MPI or Ethernet connection to the PLC. Verify the WinCC project communication settings and restart the runtime application.
    Event ID: 500
    Power supply undervoltage — the 24 V DC supply voltage has dropped below the minimum operating threshold.
    Measure the supply voltage at the power input connector. Ensure the power supply unit provides a stable 24 V DC within the specified tolerance.
    Event ID: 600
    Hard disk or storage media error — the system detects read/write errors on the internal storage device.
    Run a disk check utility. Replace the hard disk drive or CompactFlash card if errors persist. Restore the system image from backup.
    Event ID: 700
    Fan failure warning — the system cooling fan has stopped or is operating below the minimum speed threshold.
    Inspect and clean the fan assembly. Replace the fan unit if it is not operating correctly to prevent thermal shutdown.
    Event ID: 800
    BIOS configuration lost — the CMOS battery has discharged, causing loss of BIOS settings and incorrect system time.
    Replace the internal CMOS battery (typically CR2032). Re-enter BIOS settings and reconfigure date, time, and boot order.

    Frequently Asked Questions

    What display size and resolution does the 6AV7611-0AF32-0CE0 have?

    This Panel PC features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and a resistive touchscreen interface.

    What operating systems are compatible with this Panel PC?

    The SIMATIC Panel PC 670 is compatible with Windows XP and Windows 2000. It supports SIMATIC WinCC and other standard PC-based HMI and SCADA software.

    What is the supply voltage for the 6AV7611-0AF32-0CE0?

    The unit operates on a 24 V DC supply voltage, which is standard for Siemens SIMATIC Panel PC products.

    What communication interfaces are available on this unit?

    The Panel PC 670 provides Ethernet (RJ45), RS-232, and RS-422/485 serial interfaces, enabling connectivity to PLCs, networks, and peripheral devices.

    Is the front panel of this Panel PC sealed against dust and water ingress?

    Yes, the front panel carries an IP65 protection rating, making it suitable for installation in environments where dust and water spray may be present.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the power input connector. Verify that the internal backlight inverter is functioning by listening for a faint high-frequency tone. Inspect internal display cable connections.

    Restore the supply voltage to within specification. If the backlight inverter has failed, replace the inverter board or the complete display assembly. Reseat internal display cables if loose.

    Touchscreen input is inaccurate or unresponsive

    Attempt to recalibrate the touchscreen using the Windows control panel calibration utility. Check for physical damage or contamination on the touch surface. Inspect the touch controller ribbon cable connection.

    Perform a full touchscreen recalibration. Clean the touch surface with a soft, dry cloth. If the touch controller is faulty, replace the touchscreen assembly or the touch controller board.

    Panel PC fails to boot or hangs at startup

    Connect an external monitor via the VGA port to determine if the issue is display-related or system-related. Check the internal hard disk or CompactFlash card for errors using a bootable diagnostic tool.

    Replace or reformat the storage device and restore the operating system image from a backup. If the motherboard is faulty, the unit will require board-level repair or replacement.

    Loss of network communication with PLC

    Verify the Ethernet cable and switch port are functioning. Check the IP address and subnet mask configuration in Windows. Confirm the WinCC project communication channel settings match the PLC configuration.

    Correct any IP address conflicts or misconfiguration. Replace the Ethernet cable if damaged. Update or reinstall the network adapter driver if the interface is not detected.

    System time resets to default after each power cycle

    This indicates the internal CMOS battery has discharged. Enter the BIOS setup at startup to confirm that date and time settings are lost between power cycles.

    Replace the internal CMOS battery (typically a CR2032 coin cell). After replacement, re-enter the correct date, time, and BIOS settings, then save and exit.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart