Siemens 6AV7611-0AF32-0AJ0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AF32-0AJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, enabling it to run standard Windows-based SCADA and HMI software alongside industrial control applications.
The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels and a touch-sensitive screen for operator interaction. It is built around an x86-compatible processor platform and supports standard PC interfaces including USB, Ethernet (RJ45), and serial COM ports for integration with PLCs and field devices. The unit is designed for panel mounting with an IP65-rated front face for protection against dust and water ingress, and operates on a 24 V DC supply voltage. Onboard memory and storage options support the execution of WinCC flexible, SIMATIC WinCC, and other Siemens visualization software packages.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building applications where a full PC-based HMI solution is required. Its rugged industrial design makes it suitable for installation in control cabinets and operator panels in industries such as automotive, food and beverage, chemical processing, and discrete manufacturing. The combination of standard PC connectivity and industrial-grade hardware allows it to serve as a central visualization and data acquisition node on the factory floor.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Communication Interface | Ethernet RJ45, USB, RS-232 (COM ports) |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
| Operating System | Windows XP Embedded / Windows 2000 |
Common Error Codes & System Events
- Event ID: 1001
- Application error or software exception in the HMI runtime environment, typically logged in the Windows Event Viewer.
Check the Windows Event Viewer for detailed error information. Restart the HMI runtime application. If persistent, reinstall the HMI software or restore from a backup image. - Event ID: 1003
- System crash or unexpected shutdown recorded by the operating system, indicating a critical software or hardware fault.
Review the Event Viewer system log for the crash dump details. Check RAM integrity and CPU temperature. Update or reinstall device drivers if a hardware conflict is identified. - Communication Error
- Loss of communication between the Panel PC and a connected PLC or field device via Ethernet or serial interface.
Verify network cable connections and IP address configuration. Check PLC communication settings and ensure the correct communication driver is active in the HMI project. - Runtime Startup Failure
- The WinCC or WinCC flexible runtime fails to start after Windows boot, preventing the HMI application from loading.
Check the project file integrity and ensure the correct runtime version is installed. Verify that the project is correctly transferred and that the startup configuration in the HMI settings points to the correct project file. - Watchdog Timeout
- The hardware watchdog timer has triggered a system reset due to the operating system or application becoming unresponsive.
Investigate CPU load and running background processes. Reduce system load, disable unnecessary startup programs, and ensure the HMI application is optimized for the available hardware resources. - Storage Media Error
- Read/write error on the internal CompactFlash card or hard disk, which may cause data loss or failure to boot.
Run a disk check utility (chkdsk) on the storage media. If errors persist, back up all data and replace the CompactFlash card or hard drive. Restore the system image from a known-good backup. - Temperature Warning
- Internal system temperature has exceeded the recommended operating threshold, risking hardware damage or instability.
Check that the panel enclosure ventilation is unobstructed. Verify that the ambient temperature is within the 0 °C to 45 °C operating range. Clean any dust from ventilation openings and check cooling fan operation if applicable.
Frequently Asked Questions
What operating systems are supported on the SIMATIC Panel PC 670 (6AV7611-0AF32-0AJ0)?
This Panel PC was supplied with Windows XP Embedded or Windows 2000, depending on the order configuration. It supports Siemens WinCC flexible and SIMATIC WinCC visualization software.
What is the supply voltage for this Panel PC?
The 6AV7611-0AF32-0AJ0 operates on a 24 V DC supply voltage, which is standard for Siemens SIMATIC panel-mounted devices.
What is the IP protection rating of this unit?
The front face of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it resistant to dust and water jets. The rear of the unit is not rated to the same level and must be installed inside a suitable enclosure.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), USB ports, and RS-232 serial COM ports, enabling connectivity to PLCs, barcode scanners, printers, and other industrial peripherals.
Can this Panel PC be used as a replacement for older SIMATIC Panel PC 670 variants?
In many cases yes, provided the software image and project configuration are compatible. However, differences in processor speed, memory, and storage media between variants should be verified before substitution to ensure full compatibility with the installed HMI application.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector using a multimeter. Verify that the internal fuse is intact. Attempt to connect an external monitor via the VGA port to determine if the issue is isolated to the display panel.
If the external monitor shows output, the internal display or backlight inverter may have failed and should be replaced. If no output is present on either display, inspect the power supply board and main board for visible damage or failed components.
Touchscreen does not respond or registers incorrect touch positions
Check the touchscreen calibration settings within the Windows control panel. Inspect the touchscreen surface for physical damage, contamination, or moisture ingress around the bezel seal.
Recalibrate the touchscreen using the Siemens calibration utility or the Windows touchscreen calibration tool. If calibration does not resolve the issue, the resistive touchscreen overlay may need to be replaced.
HMI application does not start automatically on boot
Check the Windows startup configuration and verify that the HMI runtime shortcut is present in the startup folder. Review the Event Viewer for any application errors that may have prevented the runtime from launching.
Restore the startup entry for the HMI runtime application. If the project file is corrupted, retransfer the project from the engineering station using WinCC flexible or SIMATIC WinCC. Ensure the runtime license is valid and present on the device.
Unit fails to boot and displays a disk read error or stops at the BIOS screen
The internal CompactFlash card or hard disk may have failed or become corrupted. Attempt to access the storage media from another PC using a card reader to assess its condition.
Replace the CompactFlash card with a new card of equal or greater capacity and restore the system image from a backup. If no backup exists, a fresh Windows installation and HMI software setup will be required.
Ethernet communication to PLC is intermittent or lost
Check the Ethernet cable and RJ45 connector for physical damage. Verify the IP address configuration of the Panel PC and the connected PLC. Use the ping command from the Panel PC to test network connectivity.
Replace the Ethernet cable if damaged. Reconfigure the IP address settings if there is an address conflict. If the onboard Ethernet port is faulty, an external USB-to-Ethernet adapter may be used as a temporary measure while the unit is repaired.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page