• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AF30-0BH0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AF30-0BH0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AF30-0BH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AF30-0BH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. The unit integrates a display, computing hardware, and industrial-grade I/O into a single compact enclosure suitable for direct panel mounting.

    The SIMATIC Panel PC 670 6AV7611-0AF30-0BH0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and is equipped with a touch screen interface. It runs on a Windows-based operating system and is powered by an industrial-grade processor, providing sufficient computing performance for SCADA and HMI software such as Siemens WinCC. The unit supports standard PC interfaces including USB, Ethernet (RJ45), and serial COM ports, and is designed with a fanless or low-maintenance cooling concept suited to industrial environments. The front panel meets IP65 protection rating, guarding against dust and water ingress.

    The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building applications where a robust, panel-integrated PC solution is required. It is suitable for industries such as automotive, food and beverage, chemical processing, and general factory automation. Its compatibility with Siemens WinCC and STEP 7 engineering tools makes it a natural fit for integration into existing Siemens automation architectures.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT color LCD
    Touch Technology Resistive touch screen
    Input Voltage 24 V DC
    IP Protection Rating (Front) IP65
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Communication Interface Ethernet RJ45, USB, Serial COM (RS-232)
    Operating System Windows XP Embedded
    Mounting Panel mounting
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    System startup failure — the Panel PC fails to complete the boot sequence, often due to a corrupted OS image or failed storage medium.
    Check the CompactFlash card or hard disk for errors. Restore or reinstall the operating system image using the Siemens recovery tools.
    Event ID: 1000
    Application crash — a running HMI or SCADA application (e.g. WinCC) has terminated unexpectedly.
    Review the Windows Event Viewer for application error details. Reinstall or repair the HMI software. Check for memory or hardware conflicts.
    Event ID: 7000
    Service failed to start — a required Windows service did not start during boot, which may prevent HMI software from launching.
    Check the Windows Event Log for the specific service name. Verify service startup settings and dependencies. Reinstall the software if necessary.
    Communication Error
    Loss of communication between the Panel PC and connected PLC or automation controller via Ethernet or serial interface.
    Verify network cable connections and IP address configuration. Check firewall settings and ensure the correct communication driver is installed and configured in WinCC.
    Watchdog Timeout
    The hardware watchdog has triggered a system reset due to the operating system or application becoming unresponsive.
    Investigate the cause of the system hang. Check CPU and memory utilization. Update or repair the HMI application and ensure the OS is free of errors.
    Temperature Warning
    Internal temperature of the Panel PC has exceeded the recommended operating threshold.
    Check ambient temperature and ensure adequate ventilation around the panel cutout. Clean any air vents or filters. Verify that the cooling system (fan or heatsink) is functioning correctly.
    Storage Device Error
    The CompactFlash card or hard disk drive is not detected or has reported read/write errors.
    Reseat the storage device and check connector integrity. Replace the CompactFlash card or HDD if errors persist. Restore the OS image from a backup.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7611-0AF30-0BH0?

    The unit operates on a 24 V DC supply voltage, which is standard for Siemens SIMATIC Panel PC 670 devices.

    What operating system does this Panel PC run?

    The 6AV7611-0AF30-0BH0 runs Windows XP Embedded, which is compatible with Siemens WinCC and other SIMATIC HMI software packages.

    Is this Panel PC compatible with Siemens WinCC?

    Yes, the SIMATIC Panel PC 670 is designed to run Siemens WinCC visualization software and integrates with SIMATIC S7 PLCs via Ethernet or serial communication.

    What is the front panel protection rating?

    The front panel of the 6AV7611-0AF30-0BH0 carries an IP65 protection rating, making it resistant to dust and low-pressure water jets.

    What display size and resolution does this unit have?

    The unit features a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and a resistive touch screen interface.

    Troubleshooting

    Panel PC does not power on after 24 V DC is applied

    Measure the 24 V DC supply voltage at the power input connector. Check for blown internal fuses or a faulty power supply module.

    Ensure the supply voltage is within the specified 24 V DC range. Replace any blown fuses. If the internal power supply module is faulty, replace it with a compatible Siemens spare part.

    Display remains blank or shows no image after power on

    Check whether the unit completes its boot sequence by listening for HDD or fan activity. Verify the display backlight is functioning by shining a light at the screen to detect a faint image.

    If the backlight has failed, replace the CCFL backlight or the display assembly. If the unit is not booting, check the CompactFlash card or HDD and restore the OS image if corrupted.

    Touch screen does not respond or is inaccurate

    Verify that the touch screen driver is correctly installed in the operating system. Check for physical damage or contamination on the touch surface.

    Recalibrate the touch screen using the Windows calibration utility. If calibration does not resolve the issue, check the touch controller connection internally or replace the touch screen overlay.

    Loss of communication with PLC or network devices

    Check the Ethernet cable and switch/hub connections. Verify the IP address configuration of the Panel PC and the connected PLC. Use the ping command to test network connectivity.

    Correct any IP address conflicts or misconfiguration. Replace the Ethernet cable if faulty. Reinstall or reconfigure the communication driver in WinCC if the network hardware is confirmed functional.

    System freezes or reboots unexpectedly during operation

    Check the Windows Event Viewer for critical errors or watchdog timeout events. Monitor CPU and memory usage for resource exhaustion. Inspect the internal temperature using BIOS or monitoring software.

    Ensure adequate ventilation around the panel installation. Reduce the load on the CPU by optimizing the HMI application. If hardware faults are detected, replace the affected component such as RAM or the storage device.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart