• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AF20-0CE0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AF20-0CE0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AF20-0CE0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AF20-0CE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated industrial PC platform, offering a compact and robust solution for process visualization and control.

    The SIMATIC Panel PC 670 6AV7611-0AF20-0CE0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with standard PC interfaces including USB, serial (COM), and parallel ports, as well as Ethernet connectivity for network integration. The unit runs on a Windows-based operating system and is built with an industrial-grade fanless or low-noise cooling design to ensure reliability in continuous operation. It supports integration with Siemens SIMATIC WinCC and other SCADA/HMI software packages.

    The SIMATIC Panel PC 670 is widely used in manufacturing, process industries, and machine building where a full PC-based HMI platform is required. It is suitable for applications such as production line visualization, batch control, and data acquisition in industries including automotive, food and beverage, chemical, and pharmaceutical. Its panel-mount form factor and industrial-grade construction make it appropriate for direct integration into control cabinets and operator stations.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT color LCD
    Touch Technology Resistive touch screen
    Input Voltage 24 V DC
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    IP Protection Rating IP65 (front panel)
    Mounting Panel mounting
    Communication Interface Ethernet (RJ45), USB, RS-232 (COM), Parallel port
    Operating System Windows XP / Windows 2000
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes & System Events

    Blue Screen (BSOD)
    Windows operating system has encountered a critical error and halted, typically caused by a driver conflict, hardware fault, or corrupted OS files.
    Note the stop code displayed, reboot the unit, and check for recently installed drivers or software. Restore OS from backup image if the issue persists.
    No Boot Device Found
    The Panel PC cannot locate a bootable device, indicating a failed or disconnected CompactFlash card, hard disk, or corrupted boot sector.
    Check the storage medium connection and integrity. Replace the CompactFlash card or hard drive and restore the system image using the Siemens recovery procedure.
    Watchdog Timeout
    The system watchdog timer has expired, indicating the operating system or application has become unresponsive.
    Restart the Panel PC. Investigate application software for infinite loops or resource deadlocks. Update or reinstall the HMI application if the fault recurs.
    Ethernet Link Fault
    No network link is detected on the Ethernet interface, preventing communication with PLCs or SCADA systems.
    Check the Ethernet cable and switch port. Verify IP address configuration in Windows network settings. Test with a known-good cable and switch port.
    Touch Screen Not Responding
    The resistive touch screen does not register input, which may be caused by a calibration error, damaged touch controller, or driver issue.
    Recalibrate the touch screen using the Windows control panel touch calibration utility. If unresponsive after calibration, check the touch controller ribbon cable connection internally.
    Fan Failure Warning
    A cooling fan has stopped or is operating below the required speed threshold, risking thermal shutdown.
    Power down the unit and inspect the fan for obstruction or mechanical failure. Replace the fan with the correct Siemens spare part to restore adequate cooling.
    CMOS Battery Low
    The CMOS backup battery voltage is low, causing loss of BIOS settings and real-time clock data after power cycles.
    Replace the internal CMOS coin cell battery (typically CR2032) and re-enter BIOS settings including date, time, and boot order.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7611-0AF20-0CE0?

    The SIMATIC Panel PC 670 6AV7611-0AF20-0CE0 operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.

    What operating system does this Panel PC support?

    This unit supports Windows XP Professional or Windows 2000, which are the operating systems compatible with the SIMATIC Panel PC 670 hardware platform. Siemens WinCC and other SIMATIC HMI software can be installed on these operating systems.

    Is the front panel of the 6AV7611-0AF20-0CE0 rated for wash-down or dusty environments?

    The front panel of this unit carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for use in industrial environments.

    What HMI software is compatible with this Panel PC?

    The SIMATIC Panel PC 670 is compatible with Siemens SIMATIC WinCC, WinCC flexible, and other standard PC-based SCADA and HMI software packages that run on Windows XP or Windows 2000.

    Can the storage medium be replaced or upgraded on this unit?

    Yes, the SIMATIC Panel PC 670 uses a replaceable storage medium such as a CompactFlash card or hard disk drive, which can be replaced or upgraded. A system image must be restored after replacement using the Siemens recovery procedure.

    Troubleshooting

    Display remains blank after power on

    Check that 24 V DC is present at the power input connector. Verify the display backlight is not failed by observing the screen at an angle in a dark environment for a faint image.

    If supply voltage is correct but display is blank, replace the backlight inverter or the TFT display assembly. If no voltage is present, check the external power supply and wiring.

    Panel PC does not boot and shows a black screen with no POST activity

    Attempt to access the BIOS by connecting an external keyboard via USB and pressing the appropriate key during power-on. Check if the CompactFlash card or hard drive is detected in BIOS.

    If the storage medium is not detected, reseat or replace the CompactFlash card or hard drive and restore the system image. If BIOS is not accessible, the motherboard may require repair or replacement.

    Touch screen input is inaccurate or offset from the displayed position

    This is typically a calibration issue. Access the touch screen calibration utility through the Windows Control Panel or the Siemens-provided calibration tool.

    Run the touch screen recalibration procedure. If the problem persists after calibration, inspect the touch screen overlay for physical damage or contamination and replace if necessary.

    Unit loses date and time settings after each power cycle

    This indicates a depleted CMOS backup battery. Enter the BIOS after power-on to confirm that date and time are reset to default values.

    Power down the unit, open the enclosure, and replace the CMOS coin cell battery (typically CR2032). Re-enter the correct BIOS settings including date, time, and boot device order after replacement.

    Communication with PLC or SCADA system is intermittent or lost

    Check the Ethernet cable connection and verify the link LED on the RJ45 port is active. Use the Windows network diagnostics to ping the PLC or SCADA server IP address.

    Replace the Ethernet cable if damaged. Verify IP address, subnet mask, and gateway settings in Windows network configuration. Check the network switch port and VLAN settings. If the onboard NIC is faulty, a USB-to-Ethernet adapter may be used as a temporary measure.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart