The Siemens 6AV7611-0AF20-0BE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, enabling it to run standard Windows-based SCADA and HMI software alongside industrial control applications.
The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels and is equipped with a touch-sensitive screen for operator interaction. It is built around an industrial-grade processor and supports standard PC interfaces including USB, serial (RS-232), and Ethernet (RJ45) for integration into existing automation networks. The unit is designed for panel mounting with an IP65 protection rating on the front face, making it resistant to dust and water ingress in the operator area. It operates on a 24 V DC supply and is built to withstand the temperature and vibration conditions typical of industrial environments.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building applications where a full PC-based HMI solution is required. It is suitable for industries such as automotive, food and beverage, chemical processing, and packaging, where operators need a robust, panel-integrated computing platform. Its compatibility with Siemens WinCC and other SCADA software makes it a practical choice for visualization and data acquisition tasks on the factory floor.
Technical Specifications
| Series | SIMATIC Panel PC 670 |
|---|---|
| Display Size | 12 inch |
| Display Type | TFT LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Communication Interface | Ethernet (RJ45), USB, RS-232 |
| Mounting | Panel mounting |
| Certifications | CE, UL |
| Operating System | Windows XP Embedded / Windows 2000 |
Common Error Codes and System Events
- Event ID: 1000
- Application error in the HMI runtime software, typically caused by a software exception or crash in the WinCC or ProTool runtime environment.
Restart the HMI runtime application. Check the Windows event log for details. Reinstall or repair the runtime software if the error persists. - Event ID: 7036
- A system service has stopped unexpectedly, which may affect HMI communication or data acquisition functions.
Check Windows Services to identify which service stopped. Restart the affected service and configure it to restart automatically on failure. - Communication Error
- Loss of communication between the Panel PC and the connected PLC or automation controller, resulting in no data exchange.
Verify Ethernet or serial cable connections. Check IP address configuration and network settings. Confirm the PLC is powered and running. Restart the communication driver in WinCC. - Watchdog Timeout
- The system watchdog has detected that the operating system or application has become unresponsive and has triggered a reset.
Check for excessive CPU load or memory usage. Ensure no background processes are consuming resources. Update or reinstall the runtime software if the issue recurs. - Drive Read/Write Error
- The internal storage device (hard disk or CompactFlash) has reported a read or write error, which may indicate media degradation.
Run a disk check utility (chkdsk) to identify and repair file system errors. Back up all project data immediately. Replace the storage medium if errors persist. - Temperature Warning
- The internal temperature sensor has detected that the Panel PC is operating above the recommended thermal threshold.
Check that ventilation around the panel cutout is unobstructed. Verify ambient temperature is within the specified operating range of 0 °C to +45 °C. Clean any dust from ventilation openings. - Power Supply Fault
- The 24 V DC supply voltage has dropped below the minimum operating threshold, causing unstable operation or shutdown.
Measure the supply voltage at the power input connector. Ensure the power supply unit is rated for the Panel PC load. Check wiring for loose connections or voltage drops.
Frequently Asked Questions
What operating systems are supported by the SIMATIC Panel PC 670 (6AV7611-0AF20-0BE0)?
The Panel PC 670 supports Windows XP Embedded and Windows 2000, depending on the specific configuration ordered. It is designed to run Siemens WinCC and ProTool runtime software for HMI visualization.
What is the display size and resolution of this Panel PC?
The 6AV7611-0AF20-0BE0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA). The screen uses resistive touch technology for operator input.
What is the supply voltage for this Panel PC?
The unit operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs in this series.
Is the SIMATIC Panel PC 670 compatible with Siemens S7 PLCs?
Yes, the Panel PC 670 can communicate with Siemens S7-300 and S7-400 PLCs via Ethernet (PROFINET/Industrial Ethernet) or MPI/PROFIBUS using appropriate communication cards or adapters, when running WinCC or compatible HMI software.
What is the front panel protection rating of this unit?
The front panel of the 6AV7611-0AF20-0BE0 carries an IP65 protection rating, providing full protection against dust ingress and resistance to water jets from any direction.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power input connector. Verify the internal fuse is intact. Determine whether the PC is booting by listening for hard disk activity or checking for any LED indicators.
Restore the correct 24 V DC supply if voltage is absent or out of range. Replace the internal fuse if blown. If the PC boots but the display remains blank, check the display cable connection internally or replace the backlight inverter board.
Touchscreen does not respond or responds inaccurately
Determine whether the issue is a calibration problem or a hardware fault by attempting to use a USB mouse. Check if the touch controller driver is loaded correctly in Windows Device Manager.
Recalibrate the touchscreen using the Windows touchscreen calibration utility. If calibration does not resolve the issue, reinstall the touch controller driver. Replace the touchscreen overlay if the hardware is physically damaged.
Panel PC fails to boot into Windows and shows a blue screen or stops at POST
Check the internal storage device for errors using a bootable diagnostic tool. Verify that RAM modules are seated correctly. Review any error messages displayed during POST for hardware fault indications.
Run chkdsk or a disk diagnostic utility to check the storage medium. Reseat RAM if accessible. Restore the operating system from a backup image. Replace the CompactFlash card or hard disk if the storage medium is found to be faulty.
Loss of communication with PLC during operation
Check the Ethernet or serial cable connections between the Panel PC and the PLC. Verify the IP address configuration in Windows network settings. Confirm the PLC is in RUN mode and the communication driver in WinCC is active.
Replace or reseat the communication cable. Correct any IP address conflicts or misconfiguration. Restart the WinCC communication driver. If using a PROFIBUS or MPI card, check the card seating and driver installation.
System runs slowly or HMI application freezes intermittently
Check CPU and memory utilization in Windows Task Manager. Identify any background processes consuming excessive resources. Check the storage device for fragmentation or low free space.
Terminate unnecessary background processes and disable non-essential startup programs. Defragment the hard disk or replace a degraded CompactFlash card. Increase virtual memory allocation if RAM is insufficient for the runtime application.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page