• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AF12-0AG0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AF12-0AG0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AF12-0AG0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AF12-0AG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and rugged solution for process visualization and control.

    The SIMATIC Panel PC 670 6AV7611-0AF12-0AG0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports 256 colors. It is equipped with an Intel Celeron processor and runs on a Windows-based operating system, providing compatibility with standard SCADA and HMI software packages including SIMATIC WinCC. The unit offers multiple communication interfaces including Ethernet (RJ45) and serial ports, and supports expansion via PCI slots for additional I/O or fieldbus cards. The front panel is rated IP65 for protection against dust and water ingress.

    The SIMATIC Panel PC 670 is widely used in the manufacturing, automotive, food and beverage, and chemical processing industries. It is typically installed in control cabinets or operator panels where a full PC-based HMI platform is required for complex visualization, data logging, and process control applications. Its industrial-grade construction and compatibility with Siemens automation systems make it suitable for integration into SIMATIC S7 PLC environments.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT LCD
    Display Colors 256 colors
    Input/Operating Voltage 24 V DC
    IP/Protection Rating IP65 (front panel)
    Communication Interface Ethernet (RJ45), RS-232 serial
    Operating System Windows XP / Windows 2000 (factory configurable)
    Processor Intel Celeron
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5 % to 95 % (non-condensing)
    Mounting Panel mounting
    Certifications CE, UL
    Series/Product Family SIMATIC Panel PC 670

    Common Error Codes & System Events

    Event ID: 100
    Operating system startup failure or boot error detected during POST sequence.
    Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat memory modules. Replace storage media if corrupted.
    Event ID: 200
    Watchdog timeout triggered — application software stopped responding within the defined monitoring interval.
    Restart the HMI application. Check for software deadlocks or resource conflicts. Update or reinstall the HMI runtime software if the issue persists.
    Event ID: 300
    Ethernet communication failure — loss of connection to PLC or network host detected.
    Check Ethernet cable and connector integrity. Verify IP address configuration and network switch status. Confirm PLC communication settings match the Panel PC configuration.
    Event ID: 400
    Backlight failure or display brightness fault detected.
    Check backlight inverter board and connections. Replace the CCFL backlight lamp or inverter unit if the display remains dark with the system otherwise operational.
    Event ID: 500
    Fan failure or thermal overtemperature warning — internal cooling fan not detected or ambient temperature exceeded threshold.
    Clean or replace the internal cooling fan. Ensure adequate ventilation around the panel. Verify ambient operating temperature is within the 0 °C to +45 °C specification.
    Event ID: 600
    Battery low warning — CMOS/RTC backup battery voltage below threshold, risk of BIOS settings and real-time clock data loss.
    Replace the internal CMOS backup battery (typically CR2032 lithium coin cell). Reset BIOS date, time, and settings after replacement.
    Event ID: 700
    Hard disk or storage media read/write error detected during operation.
    Run a disk diagnostic utility. Back up data immediately. Replace the hard disk drive or CompactFlash card and reinstall the operating system and HMI software.

    Frequently Asked Questions

    What is the supply voltage for the Siemens 6AV7611-0AF12-0AG0?

    The unit operates on a 24 V DC supply voltage, which is standard for SIMATIC Panel PC 670 series devices.

    What is the display size and resolution of this Panel PC?

    The 6AV7611-0AF12-0AG0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA).

    Is this Panel PC compatible with Siemens SIMATIC WinCC?

    Yes, the SIMATIC Panel PC 670 is designed to run SIMATIC WinCC and other Windows-based HMI and SCADA software packages.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7611-0AF12-0AG0 is rated IP65, providing full protection against dust and water jets.

    Can this Panel PC be expanded with additional interface cards?

    Yes, the SIMATIC Panel PC 670 supports PCI expansion slots, allowing the installation of additional fieldbus, I/O, or communication cards to extend functionality.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power input connector. Verify that the backlight is functioning by shining an external light source at the screen to check for faint image.

    If supply voltage is correct but display is blank, replace the backlight inverter or CCFL lamp. If no image is visible at all, check the video signal path and reseat the display cable connections internally.

    Panel PC fails to boot or hangs at startup screen

    Attempt to boot from an external source if possible. Check BIOS POST messages for error indications. Inspect the hard disk or CompactFlash storage for physical damage or corruption.

    Replace the storage media and reinstall the operating system and HMI software. If the issue persists after storage replacement, inspect RAM modules and reseat or replace them.

    Touchscreen does not respond or is inaccurate

    Check whether the touchscreen controller is recognized in the operating system device manager. Attempt touchscreen recalibration using the system control panel utility.

    Recalibrate the touchscreen via the Siemens or OS-provided calibration tool. If unresponsive, check the touchscreen controller board connections. Replace the touchscreen overlay or controller board if calibration fails.

    Loss of communication with PLC via Ethernet

    Verify the Ethernet cable connection and check the link LED on the RJ45 port. Ping the PLC IP address from the Panel PC to confirm network connectivity.

    Replace the Ethernet cable if faulty. Verify IP address, subnet mask, and gateway settings on both the Panel PC and PLC. Check network switch or hub for faults. Reconfigure communication settings in the HMI project if necessary.

    System clock resets to incorrect date and time after power cycle

    This symptom indicates a depleted CMOS backup battery. Confirm by checking BIOS settings after a full power-down cycle.

    Replace the internal CMOS lithium coin cell battery (typically CR2032). After replacement, reset the correct date, time, and BIOS configuration settings.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart