Siemens 6AV7611-0AE32-0AH0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AE32-0AH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. The unit integrates a flat-panel display with a built-in computing platform, offering a compact all-in-one solution for process visualization and control.
The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs on Microsoft Windows XP or Windows 2000 operating systems, providing compatibility with standard SCADA and HMI software packages including WinCC and ProTool/Pro. The unit offers multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), and is designed for front-panel mounting with an IP65 protection rating on the front face.
The SIMATIC Panel PC 670 is widely deployed in manufacturing automation, process industries, and machine tool applications where a robust, industrially hardened computing platform is required. Its compatibility with Siemens SIMATIC software and standard Windows-based applications makes it suitable for integration into existing SIMATIC S7 PLC environments. Typical installations include production line control stations, packaging machinery, and process plant operator workstations.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touch screen |
| Processor | Intel Celeron |
| Operating System | Windows XP / Windows 2000 |
| Input/Operating Voltage | 24 V DC |
| Front Protection Rating | IP65 |
| Rear Protection Rating | IP20 |
| Communication Interface | Ethernet (RJ45), USB, RS-232, RS-422/RS-485 |
| Mounting | Panel mounting (front flush) |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Certifications | CE, UL, cUL |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to boot correctly, possibly due to corrupted system files or hardware fault.
Check hard disk or CompactFlash card integrity. Reinstall the operating system or restore from a system backup image. - Event ID: 200
- Watchdog timeout — the application software stopped responding within the configured watchdog interval.
Restart the application. Check for software deadlocks or excessive CPU load. Update or reinstall the HMI runtime software. - Event ID: 300
- Communication error — loss of connection to the PLC or controller over the configured interface.
Verify Ethernet or serial cable connections. Check PLC communication settings and ensure IP addresses or station addresses match the project configuration. - Event ID: 400
- Touch screen calibration error — touch input is misaligned or unresponsive.
Run the touch screen calibration utility from the Windows Control Panel or SIMATIC settings. Clean the touch surface and check for physical damage. - Event ID: 500
- Fan failure or overtemperature warning — internal temperature has exceeded the safe operating threshold.
Check that ventilation slots are unobstructed. Verify ambient temperature is within specification. Inspect and replace the cooling fan if faulty. - Event ID: 600
- Storage medium error — read/write error detected on the hard disk or CompactFlash storage device.
Run a disk check utility. Replace the CompactFlash card or hard disk if errors persist. Restore the system image from backup. - Event ID: 700
- Power supply undervoltage — the 24 V DC supply voltage has dropped below the minimum operating threshold.
Measure the supply voltage at the power connector. Ensure the power supply unit is rated for the Panel PC load and check wiring for voltage drop. - Event ID: 800
- USB device error — an attached USB peripheral is not recognized or has caused a system conflict.
Disconnect the USB device and restart the Panel PC. Use only approved USB peripherals and ensure drivers are correctly installed under the operating system.
Frequently Asked Questions
What is the supply voltage for the SIMATIC Panel PC 670 (6AV7611-0AE32-0AH0)?
The unit operates on a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance range.
What operating systems are supported by this Panel PC?
The SIMATIC Panel PC 670 supports Microsoft Windows XP Professional and Windows 2000. It is compatible with Siemens WinCC and ProTool/Pro runtime software.
What is the front panel protection rating of this unit?
The front panel of the 6AV7611-0AE32-0AH0 carries an IP65 protection rating, making it resistant to dust ingress and water jets, suitable for industrial panel mounting.
Can this Panel PC communicate with Siemens S7 PLCs?
Yes, the Panel PC 670 supports communication with SIMATIC S7-300 and S7-400 PLCs via Ethernet (TCP/IP) and optionally via MPI or PROFIBUS with appropriate interface cards.
Is the touch screen on this unit replaceable?
The resistive touch screen assembly can be replaced as a spare part. Recalibration using the Windows Control Panel or SIMATIC calibration tool is required after replacement.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector. Verify the internal fuse and inspect the backlight inverter board for visible damage.
Replace the fuse if blown. If the backlight is faulty, replace the backlight inverter or the complete display assembly. Confirm supply voltage is within 24 V DC tolerance.
Touch screen does not respond or registers incorrect input positions
Attempt to recalibrate the touch screen using the SIMATIC calibration utility. Check for physical damage, contamination, or moisture on the touch surface.
Run the touch calibration routine from the Control Panel. Clean the screen surface with a dry cloth. If calibration fails repeatedly, replace the touch screen overlay.
Panel PC fails to boot into Windows or shows a boot error
Check the CompactFlash card or hard disk for errors using a disk diagnostic tool. Inspect for corrupted system files caused by an improper shutdown or power loss.
Restore the system from a backup image. If the storage medium is faulty, replace the CompactFlash card or hard disk and reinstall the operating system and HMI software.
Loss of communication with the connected PLC
Verify Ethernet cable connections and check the IP address configuration on both the Panel PC and the PLC. Use the Windows network diagnostics or ping command to test connectivity.
Correct any IP address mismatches in the project configuration. Replace the Ethernet cable if damaged. Restart both the Panel PC and the PLC to re-establish communication.
Unit overheats and shuts down unexpectedly
Check that the ambient temperature is within the 0 to 45 degrees Celsius operating range. Inspect ventilation openings for blockage and verify the internal cooling fan is operating.
Clear any obstructions from ventilation slots. Replace the internal cooling fan if it is not spinning. Reduce ambient temperature by improving enclosure ventilation or adding external cooling.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page