Siemens 6AV7611-0AE22-0CE0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AE22-0CE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial-grade panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7611-0AE22-0CE0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with standard PC interfaces including USB, serial (RS-232), and parallel ports, as well as an Ethernet interface for network connectivity and integration with Siemens SIMATIC automation systems. The unit runs on a Windows-based operating system and is designed to accommodate standard industrial PC software, including Siemens WinCC and other SCADA/HMI applications. The fanless or fan-cooled design options and robust aluminum front panel provide durability in industrial settings.
The SIMATIC Panel PC 670 is widely used in manufacturing, process industries, automotive production, and machine building applications where a combined HMI and PC platform is required. Its compatibility with Siemens SIMATIC S7 PLCs and PROFIBUS/Industrial Ethernet networks makes it suitable for integration into existing Siemens automation architectures. The unit is particularly well suited for applications requiring local visualization, data logging, and supervisory control at the machine or panel level.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Type | TFT LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Communication Interface | Ethernet (RJ45), RS-232, USB, Parallel |
| Operating System | Windows XP / Windows 2000 (embedded) |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Protection Rating (Front) | IP65 |
| Protection Rating (Rear) | IP20 |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to boot correctly or a critical system file is missing.
Check the hard disk or CompactFlash card for integrity. Reinstall or restore the operating system image using the Siemens recovery medium. - Event ID: 1000
- Application fault — an HMI or SCADA application (e.g. WinCC) has crashed or terminated unexpectedly.
Review the Windows Event Viewer for application error details. Reinstall or repair the affected software. Check for software compatibility with the installed OS version. - Hardware Error: HDD
- Hard disk drive failure or read/write error detected.
Replace the internal hard disk drive or CompactFlash storage medium. Restore the system image from backup media. - BIOS POST Error
- Power-On Self-Test failure during startup, indicating a hardware component fault (RAM, CPU, or peripheral).
Reseat RAM modules and internal connectors. If the error persists, identify the failing component via BIOS beep codes and replace accordingly. - Watchdog Timeout
- The system watchdog timer has expired, indicating the operating system or application has become unresponsive.
Investigate software processes causing system hang. Ensure the WinCC or HMI runtime application is correctly configured. Check CPU load and available memory. - Network Communication Error
- Loss of communication between the Panel PC and the connected PLC or network device via Ethernet or PROFIBUS.
Verify Ethernet cable connections and network switch status. Check IP address configuration and ensure the PLC is online. Review WinCC communication channel settings. - Temperature Warning
- Internal temperature of the Panel PC has exceeded the recommended operating threshold.
Check that ventilation slots are not blocked. Verify the cooling fan (if fitted) is operational. Ensure ambient temperature is within the 0 °C to +50 °C operating range. - Touch Screen Fault
- Touch input is not responding or is registering incorrect coordinates.
Recalibrate the touchscreen using the Siemens calibration utility in the Control Panel. If calibration fails, inspect the touch controller connection or replace the touch overlay.
Frequently Asked Questions
What is the supply voltage for the 6AV7611-0AE22-0CE0?
The SIMATIC Panel PC 670 (6AV7611-0AE22-0CE0) operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel devices.
What display size and resolution does this Panel PC have?
This unit features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA), suitable for detailed process visualization screens.
Is this Panel PC compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is designed to run Siemens WinCC and other SCADA/HMI software packages that are compatible with the installed Windows operating system.
What communication interfaces are available on this unit?
The 6AV7611-0AE22-0CE0 provides Ethernet (RJ45), RS-232 serial, USB, and parallel interfaces, enabling connectivity to PLCs, network infrastructure, and peripheral devices.
What is the front panel protection rating of this device?
The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it resistant to dust ingress and water jets, suitable for panel-mounted industrial environments.
Troubleshooting
Panel PC does not power on after 24 V DC is applied
Measure the 24 V DC supply voltage at the power input connector. Check the internal fuse and verify the power supply unit output voltages.
Replace the internal fuse if blown. If the power supply unit is faulty, replace it. Ensure the 24 V DC supply is stable and within the specified tolerance range.
Display is blank but the system appears to be running (LEDs active, HDD activity)
Check the display backlight by shining a torch at the screen to see if a faint image is visible. Inspect the display cable connection between the mainboard and the LCD panel.
Replace the CCFL backlight or inverter board if the backlight has failed. If the display cable is loose or damaged, reseat or replace it. In severe cases, replace the LCD panel assembly.
Touchscreen input is inaccurate or unresponsive
Attempt touchscreen recalibration via the Windows Control Panel calibration utility. Check for physical damage or contamination on the touch surface.
Recalibrate the touchscreen. Clean the touch surface with a soft, dry cloth. If recalibration does not resolve the issue, replace the resistive touch overlay or touch controller board.
System freezes or reboots unexpectedly during operation
Check the Windows Event Viewer for critical errors or watchdog timeout events. Monitor CPU temperature and system resource usage. Inspect the CompactFlash or HDD for errors using disk diagnostic tools.
Replace the storage medium if disk errors are found. Ensure adequate ventilation and that the cooling fan is operational. Reduce CPU load by optimizing the HMI application or upgrading RAM if possible.
No communication with PLC via Ethernet
Verify the Ethernet cable is connected and the link LED on the RJ45 port is active. Ping the PLC IP address from the Panel PC command prompt. Check WinCC communication channel configuration.
Replace the Ethernet cable if faulty. Correct the IP address settings on the Panel PC or PLC. Reconfigure the WinCC communication driver and ensure the PLC program is running and accessible on the network.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page