Siemens 6AV7611-0AE22-0AF0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AE22-0AF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. The unit integrates a flat-panel display with a built-in computing platform, offering a compact and rugged all-in-one solution for process visualization and control.
The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs on Microsoft Windows operating systems, supporting SIMATIC WinCC and other Siemens visualization software. The unit provides standard PC interfaces including USB, serial (COM), and Ethernet ports, enabling integration with a wide range of automation and IT systems. It is designed for 24 V DC supply and is built to meet industrial environmental requirements including extended temperature ranges and vibration resistance.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building applications where a robust, panel-mounted PC with visualization capabilities is required. It is suitable for industries such as automotive, food and beverage, chemical processing, and general factory automation. Its compatibility with SIMATIC software and standard PC architecture makes it a flexible platform for both HMI visualization and data acquisition tasks.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Type | TFT LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Processor | Intel Celeron |
| Operating System | Windows XP / Windows 2000 |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM) |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 95% (non-condensing) |
| Protection Rating | IP65 (front panel) |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to initialize correctly during boot.
Check the integrity of the OS installation. Verify the hard disk or CompactFlash card is properly seated and functional. Reinstall the OS if necessary. - Event ID: 1000
- Application fault — a software application such as WinCC has crashed unexpectedly.
Review the Windows Event Viewer for detailed error information. Reinstall or update the affected application. Check for memory or hardware conflicts. - Event ID: 7034
- Service terminated unexpectedly — a critical Windows service stopped without a controlled shutdown.
Restart the service via Windows Service Manager. If recurring, check for software conflicts or corrupted system files and repair the OS installation. - Hardware Error: Fan Failure
- The internal cooling fan has stopped or is operating below the required speed threshold.
Inspect and clean the fan. Replace the fan unit if it is not operating correctly to prevent thermal shutdown of the panel PC. - Hardware Error: HDD/CF Failure
- The hard disk drive or CompactFlash storage medium is not detected or has reported read/write errors.
Check the physical connection of the storage device. Replace the HDD or CompactFlash card and restore the system image from a backup. - BIOS POST Error
- A Power-On Self-Test failure was detected during startup, indicating a hardware fault such as RAM or CPU issue.
Reseat all internal modules and memory. If the error persists, identify the failing component via BIOS diagnostics and replace the defective hardware. - Watchdog Timeout
- The system watchdog timer has triggered a reset because the application or OS became unresponsive.
Investigate the cause of the system hang — check CPU load, memory usage, and application stability. Optimize or restart the offending process.
Frequently Asked Questions
What operating systems are supported by the SIMATIC Panel PC 670 (6AV7611-0AE22-0AF0)?
The SIMATIC Panel PC 670 supports Microsoft Windows XP and Windows 2000. It is compatible with Siemens SIMATIC WinCC and other standard PC-based HMI and SCADA software.
What is the supply voltage for the 6AV7611-0AE22-0AF0?
The unit operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs in this series.
What is the front panel protection rating of this Panel PC?
The front panel of the SIMATIC Panel PC 670 is rated IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for industrial panel mounting.
What communication interfaces are available on this unit?
The 6AV7611-0AE22-0AF0 provides Ethernet (RJ45), USB ports, and RS-232 serial (COM) interfaces, enabling connectivity to PLCs, networks, and peripheral devices.
Is the touchscreen on this Panel PC replaceable?
Yes, the resistive touchscreen assembly can be replaced as a spare part. It is recommended to use Siemens-approved replacement components to ensure compatibility and maintain the IP65 front panel rating.
Troubleshooting
Display remains blank after power on
Check that 24 V DC is present at the power input connector. Verify the backlight is functioning by shining a light at the screen to detect a faint image. Check internal fuse and power supply board.
Replace the backlight inverter or the TFT display assembly if the backlight has failed. If no power is reaching the unit, inspect the power supply module and input wiring for faults.
Touchscreen does not respond or is inaccurate
Attempt to recalibrate the touchscreen via the Windows control panel or SIMATIC touchscreen calibration utility. Check for physical damage or contamination on the screen surface.
Recalibrate the touchscreen using the built-in calibration tool. If calibration fails or the screen remains unresponsive, replace the resistive touch panel overlay and reconnect the touch controller cable.
Panel PC fails to boot or continuously restarts
Observe the BIOS POST screen for error messages. Check the hard disk or CompactFlash card for errors using BIOS diagnostics. Verify that RAM modules are properly seated.
Reseat memory modules and storage media. If the storage device is faulty, replace it and restore the system image. If a hardware component has failed, identify and replace the defective module.
Ethernet communication is not established
Check the Ethernet cable and switch port. Verify the IP address configuration in Windows Network Settings. Confirm that the network adapter is recognized in Device Manager.
Replace the Ethernet cable if damaged. Reconfigure the IP settings to match the network requirements. If the network adapter is not recognized, reinstall the driver or replace the network interface card.
System runs slowly or application performance is degraded
Check CPU and memory utilization via Windows Task Manager. Inspect the hard disk for fragmentation or errors. Verify that the cooling fan is operating and the unit is not overheating.
Close unnecessary background processes and optimize startup programs. Defragment the hard disk or replace it with a CompactFlash-based solid-state solution. Clean the cooling fan and vents to restore proper airflow.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page