• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AE20-0AE0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AE20-0AE0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AE20-0AE0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AE20-0AE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens as part of their industrial PC platform for human-machine interface and visualization applications. This unit is a rugged, panel-mounted industrial PC designed for demanding production environments where reliable operator control and process visualization are required. It combines the functionality of a standard PC with the robustness and integration features expected in industrial automation settings.

    The SIMATIC Panel PC 670 features a fanless or actively cooled processor architecture depending on the variant, with an integrated TFT flat-panel display and resistive touchscreen for operator interaction. It supports standard PC interfaces including USB, Ethernet (RJ45), and serial COM ports, enabling connectivity to Siemens S7 PLCs and third-party controllers via PROFIBUS or Industrial Ethernet. The unit runs Microsoft Windows operating systems and supports SIMATIC WinCC and other SCADA/HMI software packages, with onboard CompactFlash or hard disk storage for application data and OS.

    The SIMATIC Panel PC 670 is widely deployed in automotive manufacturing, process industries, food and beverage production, and machine tool applications where a full PC-based HMI platform is required. Its panel-mount design allows direct integration into control cabinet doors or operator stations, and its industrial-grade construction ensures reliable operation in environments with vibration, dust, and temperature variation. The platform is suitable for applications requiring complex visualization, data logging, recipe management, and integration with enterprise-level systems.

    Technical Specifications

    Series SIMATIC Panel PC 670
    Display Type TFT flat-panel
    Display Size 15 inch
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 95% (non-condensing)
    IP Protection Rating IP65 (front panel)
    Communication Interfaces Ethernet (RJ45), USB, COM (RS-232)
    Storage CompactFlash / Hard Disk Drive
    Operating System Microsoft Windows XP / Windows 2000
    Mounting Panel mount
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    Operating system boot failure or missing OS image on storage medium.
    Check CompactFlash card or hard disk for correct OS installation. Re-image the storage medium if necessary.
    Event ID: 101
    Hardware watchdog timeout — the system did not respond within the watchdog interval.
    Check CPU load and running processes. Restart the Panel PC and investigate software causing the overload.
    Event ID: 200
    Fan failure detected (on actively cooled variants) — cooling fan has stopped or is running below threshold speed.
    Inspect and clean the fan. Replace the fan unit if it is defective to prevent thermal shutdown.
    Event ID: 201
    CPU temperature exceeded permissible limit — thermal protection triggered.
    Check ambient temperature and ventilation around the Panel PC. Clean air filters and verify fan operation.
    Event ID: 300
    Communication loss to PLC — connection via Industrial Ethernet or PROFIBUS interrupted.
    Check network cables and connectors. Verify IP address configuration and PLC communication settings in WinCC.
    Event ID: 301
    WinCC Runtime startup error — HMI application failed to launch correctly.
    Check WinCC project integrity and license availability. Restart the runtime application or re-transfer the project.
    Event ID: 400
    Storage medium error — read/write error on CompactFlash or hard disk.
    Run disk diagnostics. Back up data and replace the CompactFlash card or hard disk drive if errors persist.
    Event ID: 500
    Power supply undervoltage — 24 V DC supply dropped below permissible threshold.
    Measure the 24 V DC supply at the input connector. Check the power supply unit and wiring for voltage drops.

    Frequently Asked Questions

    What is the supply voltage for the Siemens 6AV7611-0AE20-0AE0?

    The Panel PC 670 operates on a 24 V DC supply voltage. Ensure the power source is stable and within the permissible tolerance range.

    What HMI software is compatible with this Panel PC?

    The unit is compatible with Siemens SIMATIC WinCC, WinCC flexible, and other standard PC-based SCADA and visualization software packages running under Windows XP or Windows 2000.

    What is the front panel protection rating of this unit?

    The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it resistant to dust ingress and water jets from any direction.

    Can this Panel PC communicate directly with Siemens S7 PLCs?

    Yes, the Panel PC 670 supports communication with Siemens S7-300 and S7-400 PLCs via Industrial Ethernet using the S7 protocol, and optionally via PROFIBUS with an appropriate communication card.

    What storage options are available on this Panel PC?

    The unit supports CompactFlash cards for solid-state storage as well as internal hard disk drives, depending on the specific configuration ordered.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the input connector. Verify that the power LED or status indicator is active. Inspect internal fuses if accessible.

    Restore correct 24 V DC supply. If the backlight has failed, replace the CCFL backlight or the display assembly. If the unit does not boot, re-image the CompactFlash or hard disk with the correct OS.

    Touchscreen does not respond or registers incorrect touch positions

    Check if the touchscreen is physically damaged or contaminated. Verify that the touchscreen calibration has not been corrupted in the OS settings.

    Clean the touchscreen surface. Recalibrate the touchscreen using the Windows calibration utility. If the touchscreen controller is defective, replace the touchscreen assembly.

    Panel PC fails to boot into Windows and shows a boot error

    Check the CompactFlash card or hard disk drive for errors using a diagnostic tool. Verify that the boot device is correctly configured in the BIOS.

    Re-image the CompactFlash card or replace the hard disk with a correctly configured unit. Restore the OS and WinCC project from backup.

    Communication with PLC is lost intermittently

    Inspect Ethernet or PROFIBUS cables and connectors for damage or loose connections. Check the network switch or hub for faults. Verify IP address and subnet configuration.

    Replace damaged cables or connectors. Ensure the Ethernet switch is functioning correctly. Reconfigure the network settings in WinCC and verify the PLC communication parameters.

    Unit shuts down unexpectedly or restarts without warning

    Check the ambient temperature around the Panel PC and verify that ventilation clearances are maintained. Inspect the fan operation on actively cooled variants. Review the Windows event log for thermal or watchdog events.

    Improve ventilation or reduce ambient temperature. Clean dust from air vents and replace a defective fan. If the power supply is unstable, replace or stabilize the 24 V DC source.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart