• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AE10-0BH0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AE10-0BH0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AE10-0BH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AE10-0BH0 is an industrial Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is a high-performance, fanless industrial computing platform designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. The unit integrates a flat-panel display with an embedded PC architecture, providing a compact all-in-one solution for process visualization and control.

    The SIMATIC Panel PC 670 6AV7611-0AE10-0BH0 features a 10.4-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 256 colors, designed for reliable readability in industrial lighting conditions. It is equipped with standard PC interfaces including USB, serial (RS-232), and parallel ports, along with an Ethernet interface for network connectivity. The unit runs on a Windows-based operating system and supports SIMATIC WinCC and other Siemens HMI software packages. The robust aluminum front panel provides IP65 protection when properly mounted, making it suitable for harsh industrial environments.

    The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a full PC-based HMI platform is required. It is particularly suited for industries such as automotive, food and beverage, chemical processing, and discrete manufacturing, where operators require a stable, long-lifecycle visualization platform. Its compatibility with Siemens SIMATIC software and standard PC peripherals makes it a flexible choice for both new installations and system upgrades.

    Technical Specifications

    Display Size 10.4 inch
    Display Type TFT LCD
    Display Resolution 800 x 600 pixels (SVGA)
    Display Colors 256 colors
    Input/Operating Voltage 24 V DC
    IP/Protection Rating IP65 (front panel)
    Communication Interface Ethernet, RS-232, USB, Parallel
    Operating System Windows-based (WinCC compatible)
    Mounting Panel mounting
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 95% (non-condensing)
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    System startup error — the operating system failed to initialize correctly during boot.
    Check the storage medium (CompactFlash or hard disk) for errors. Verify the OS installation is intact and reboot the device.
    Event ID: 1000
    Application crash — the HMI runtime software (e.g. WinCC) has terminated unexpectedly.
    Review the Windows Event Viewer for application error details. Reinstall or repair the WinCC runtime installation if necessary.
    Event ID: 7000
    Service failed to start — a required Windows service did not start during boot.
    Check the Windows Event Log for the specific service name. Ensure all required software dependencies are installed and the service is set to automatic startup.
    BIOS POST Error
    Hardware initialization failure detected during Power-On Self-Test.
    Check all internal connections and memory modules. If the error persists, the mainboard or memory module may require replacement.
    WinCC Runtime Error
    WinCC runtime cannot establish a connection to the configured PLC or data source.
    Verify Ethernet or MPI communication settings, check cable connections, and confirm the PLC is online and reachable from the Panel PC.
    Watchdog Timeout
    The system watchdog timer has triggered, indicating the operating system or application has become unresponsive.
    Investigate CPU load and running processes. Reduce background tasks, check for software conflicts, or restore the system image to a known good state.
    Temperature Warning
    Internal temperature sensor has detected an over-temperature condition.
    Ensure adequate ventilation around the unit. Check that the installation environment does not exceed the rated operating temperature of +50 °C. Clean any dust from ventilation areas.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7611-0AE10-0BH0?

    The SIMATIC Panel PC 670 6AV7611-0AE10-0BH0 operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel devices.

    What HMI software is compatible with this Panel PC?

    The unit is compatible with Siemens SIMATIC WinCC and WinCC flexible software packages. It runs a Windows-based operating system, so other standard PC-based SCADA and visualization software may also be used.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7611-0AE10-0BH0 carries an IP65 protection rating when correctly installed in a panel cutout, providing protection against dust and water jets.

    What display size and resolution does this Panel PC have?

    The unit features a 10.4-inch TFT LCD display with a resolution of 800 x 600 pixels (SVGA) and 256 colors.

    Can this Panel PC communicate with Siemens S7 PLCs?

    Yes, the Panel PC 670 can communicate with Siemens S7-300 and S7-400 PLCs via Ethernet using standard SIMATIC communication protocols, and can also support MPI or PROFIBUS communication with appropriate interface cards.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the power connector. Check the internal fuse and verify the backlight is not faulty by observing the screen at an angle in a dark environment.

    Replace the fuse if blown. If the backlight has failed, the display unit or inverter board will require replacement. Confirm the 24 V DC supply is within tolerance.

    Touchscreen does not respond or is inaccurate

    Check if the touch controller driver is loaded correctly in the Windows Device Manager. Attempt a touchscreen recalibration using the Siemens calibration utility or Windows touch settings.

    Recalibrate the touchscreen through the control panel. If the issue persists, check the internal ribbon cable connection between the touch panel and the mainboard, or replace the touch overlay.

    Panel PC fails to boot or continuously restarts

    Observe the boot sequence for BIOS POST errors. Check the CompactFlash card or hard disk drive for errors using a diagnostic tool. Verify the 24 V DC supply is stable and within specification.

    Replace the storage medium if it is faulty. Restore the operating system image from a backup. If the mainboard is suspected, it may require professional repair or replacement.

    Loss of communication with PLC or network

    Check the Ethernet cable and port for physical damage. Verify IP address configuration in Windows network settings. Ping the PLC from the Panel PC to test network connectivity.

    Replace the Ethernet cable if damaged. Reconfigure the IP address settings to match the network. Update or reinstall the communication driver if the network adapter is not recognized.

    System clock resets to default date and time after power cycle

    This typically indicates a depleted CMOS battery on the mainboard, which maintains the real-time clock when the unit is powered off.

    Replace the CMOS battery (typically a CR2032 coin cell) on the mainboard. After replacement, set the correct date and time in the BIOS and Windows system settings.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart