
Siemens 6AV7611-0AB32-0CE0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AB32-0CE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, enabling it to run standard Windows-based SCADA and HMI software alongside process control applications.
The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels and is equipped with a touch-sensitive screen for operator interaction. It is built around an industrial-grade processor platform and supports multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-422/RS-485), enabling integration with a wide range of automation and control systems. The unit operates on a 24 V DC supply and is designed for panel mounting with an IP65-rated front face, providing protection against dust and water ingress in industrial environments.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process industries, and machine building where a full PC-based HMI solution is required. Its compatibility with Siemens SIMATIC WinCC and other standard HMI software packages makes it suitable for complex visualization tasks, data logging, and process monitoring. Industries such as automotive, food and beverage, chemical processing, and packaging commonly deploy this panel PC for supervisory control and operator interface applications.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Voltage Range | 19.2 V DC – 28.8 V DC |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Communication Interface | Ethernet (RJ45), USB, RS-232, RS-422/RS-485 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Mounting | Panel mounting |
| Operating System | Windows XP Professional / Windows 2000 |
| Certifications | CE, UL, cUL |
| Series/Product Family | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or CompactFlash card integrity. Verify BIOS settings and re-seat storage media. Replace storage device if faulty. - Event ID: 200
- Watchdog timeout triggered — the system did not respond within the defined watchdog interval.
Check CPU load and running processes. Reduce system load or increase watchdog timeout interval in BIOS or application settings. - Event ID: 300
- Fan failure detected — cooling fan has stopped or is operating below minimum speed threshold.
Inspect and clean the cooling fan. Replace the fan unit if it does not restart. Ensure ambient temperature is within specification. - Event ID: 400
- Temperature warning — internal system temperature has exceeded the warning threshold.
Check ambient temperature and ensure ventilation clearances are maintained. Clean air filters and verify fan operation. Reduce thermal load if necessary. - Event ID: 500
- Battery low warning — the CMOS/RTC backup battery voltage is below the minimum threshold.
Replace the internal CMOS backup battery (typically CR2032 or equivalent). Note BIOS settings before replacement as they may be lost. - Event ID: 600
- Ethernet communication error — loss of network connection or failure to establish link with the network.
Check Ethernet cable and switch/hub connection. Verify IP address configuration and network settings in the operating system. Replace cable or NIC if hardware fault is confirmed. - Event ID: 700
- USB device error — connected USB peripheral is not recognized or has caused a system fault.
Disconnect and reconnect the USB device. Try an alternative USB port. Check device driver installation. Replace USB device if fault persists. - Event ID: 800
- Hard disk or storage media error — read/write error detected on the primary storage device.
Run a disk check utility (chkdsk) to identify and repair file system errors. Back up data immediately. Replace the hard disk or CompactFlash card if hardware errors are confirmed.
Frequently Asked Questions
What operating systems are supported by the SIMATIC Panel PC 670 (6AV7611-0AB32-0CE0)?
The SIMATIC Panel PC 670 supports Windows XP Professional and Windows 2000 as factory-installed operating system options. The specific OS version depends on the order configuration of the unit.
What is the supply voltage for the 6AV7611-0AB32-0CE0?
The unit operates on a 24 V DC supply with an acceptable input range of 19.2 V DC to 28.8 V DC.
Is the 6AV7611-0AB32-0CE0 compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is compatible with Siemens SIMATIC WinCC and other standard PC-based HMI and SCADA software packages that run on the supported Windows operating systems.
What is the IP protection rating of the 6AV7611-0AB32-0CE0?
The front face of the panel PC is rated IP65, providing protection against dust and water jets. The rear of the unit is rated IP20.
What communication interfaces are available on this panel PC?
The 6AV7611-0AB32-0CE0 provides Ethernet (RJ45), USB ports, and serial interfaces (RS-232 and RS-422/RS-485) for connectivity to automation systems and peripherals.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector and verify it is within the 19.2–28.8 V DC range. Inspect internal fuses and check for any POST error indicators.
Restore supply voltage to the correct range. Replace any blown internal fuses. If the backlight has failed, the backlight inverter or display assembly may need replacement.
Touchscreen does not respond or responds inaccurately
Check whether the touchscreen controller is recognized in the Windows Device Manager. Determine if the issue is a calibration problem or a hardware failure by testing with a mouse.
Recalibrate the touchscreen using the calibration utility in the Windows control panel. If calibration does not resolve the issue, check the touchscreen ribbon cable connection and replace the touchscreen overlay if damaged.
System fails to boot or continuously restarts
Check the hard disk or CompactFlash storage device for errors using BIOS diagnostics. Verify that the operating system partition is intact and that no external USB devices are interfering with the boot sequence.
Run chkdsk or equivalent disk repair utility. Re-image the storage device with a valid OS image if the file system is corrupted. Replace the storage device if hardware errors are detected.
Ethernet communication is not established
Verify the Ethernet cable connection and check the link LED on the RJ45 port. Confirm IP address settings in the Windows network configuration and check for conflicts.
Replace the Ethernet cable and verify switch/hub port operation. Reconfigure the IP address settings if necessary. Update or reinstall the network adapter driver if the interface is not recognized.
System clock loses time after power off
The CMOS backup battery is likely discharged. Check the battery voltage — it should be approximately 3 V DC for a CR2032 type cell.
Replace the internal CMOS backup battery. After replacement, re-enter BIOS settings including date, time, and boot sequence configuration.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page



