• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AB32-0AJ0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AB32-0AJ0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AB32-0AJ0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AB32-0AJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. The unit combines a flat-panel display with an integrated industrial PC platform, offering a compact all-in-one solution for process visualization and control.

    The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels and a touch-sensitive screen for operator interaction. It is based on an x86-compatible processor architecture and supports Windows-based operating systems, enabling compatibility with standard SCADA and HMI software such as Siemens WinCC. The unit provides multiple communication interfaces including Ethernet (RJ45) and serial ports (RS-232), and is built to withstand industrial environments with a front-panel protection rating of IP65. Expansion options via PCI slots allow integration of additional fieldbus or communication cards.

    The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building applications where a robust, panel-integrated PC with visualization capabilities is required. It is suitable for industries such as automotive, food and beverage, chemical processing, and water treatment. Its fanless or low-maintenance design options and industrial-grade components make it appropriate for continuous operation in harsh factory floor environments.

    Technical Specifications

    Series/Product Family SIMATIC Panel PC 670
    Display Size 12 inch
    Display Technology TFT LCD
    Display Resolution 800 x 600 pixels (SVGA)
    Touch Technology Resistive touchscreen
    Input/Operating Voltage 24 V DC
    Power Consumption Approx. 60 W
    Communication Interface Ethernet (RJ45), RS-232 (COM ports)
    Front Protection Rating IP65
    Rear Protection Rating IP20
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    Mounting Panel mounting
    Operating System Windows XP / Windows 2000 (embedded)
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 1000
    Application error in the operating system or HMI runtime software has caused an unexpected termination.
    Check Windows Event Viewer for details. Reinstall or repair the HMI runtime software (e.g. WinCC flexible). Ensure all software patches are applied.
    Event ID: 6008
    The system was shut down unexpectedly, indicating a previous crash or power loss event.
    Check power supply stability at 24 V DC input. Inspect for loose connections. Review event log for preceding errors to identify root cause.
    BIOS POST Error
    Hardware component not detected during Power-On Self-Test, such as missing RAM or storage device.
    Reseat RAM modules and CompactFlash/hard disk. Verify hardware connections internally. Replace faulty memory or storage if fault persists.
    WinCC Runtime Error
    WinCC flexible or WinCC runtime fails to start or crashes during operation.
    Reinstall WinCC runtime software. Check for corrupted project files. Ensure the operating system is free of disk errors using CHKDSK.
    Network Communication Fault
    Loss of Ethernet communication between the Panel PC and the PLC or SCADA server.
    Check Ethernet cable and RJ45 connector integrity. Verify IP address configuration. Test network switch or hub. Replace Ethernet cable if damaged.
    Touchscreen Calibration Error
    Touch input is misaligned or unresponsive, causing incorrect operator inputs.
    Run the touchscreen calibration utility from the Windows Control Panel. Clean the screen surface. If unresponsive, check the touch controller connection internally or replace the touch overlay.
    Storage Device Failure
    CompactFlash card or hard disk drive is not detected or has read/write errors.
    Replace the CompactFlash card or HDD with a compatible unit. Restore the operating system and HMI project from backup. Ensure the replacement storage meets Siemens specifications for the Panel PC 670.

    Frequently Asked Questions

    What is the supply voltage for the Siemens 6AV7611-0AB32-0AJ0?

    The unit operates on a 24 V DC supply voltage, which is standard for SIMATIC Panel PC 670 devices used in industrial environments.

    What operating system does the SIMATIC Panel PC 670 support?

    The Panel PC 670 supports Windows XP Embedded or Windows 2000, and is compatible with Siemens WinCC and WinCC flexible HMI software.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7611-0AB32-0AJ0 carries an IP65 protection rating, making it resistant to dust and water jets for panel-mounted installations.

    Can the SIMATIC Panel PC 670 communicate with S7-300 or S7-400 PLCs?

    Yes, via Ethernet using standard protocols such as S7 communication or OPC. Additional fieldbus cards (e.g. PROFIBUS) can be installed in the available PCI expansion slots for direct fieldbus connectivity.

    Is the touchscreen on this Panel PC replaceable?

    Yes, the resistive touchscreen overlay is a serviceable component and can be replaced. Siemens and compatible third-party replacement touch panels are available for the 12-inch Panel PC 670 display assembly.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the input connector. Check the internal fuse and verify the power LED status. Connect an external monitor via the VGA port to determine if the issue is isolated to the display.

    If the external monitor shows output, replace the internal display or backlight inverter. If no output is present at all, inspect the internal power supply board and replace if faulty. Verify the 24 V DC input is within tolerance.

    Touchscreen does not respond to input

    Check if the Windows desktop is visible and the system is running. Attempt to use a USB mouse to confirm the OS is operational. Inspect the internal ribbon cable connecting the touch controller to the motherboard.

    Recalibrate the touchscreen using the Windows Control Panel utility. If the touch overlay is physically damaged or the controller is unresponsive, replace the touch screen assembly. Reseat the internal touch controller cable if loose.

    Panel PC fails to boot and displays BIOS error

    Observe the BIOS POST screen for error messages. Check whether the CompactFlash card or hard disk is detected in the BIOS. Reseat RAM modules and storage devices.

    Replace the CompactFlash card or hard disk with a compatible unit and restore the OS image from backup. If RAM is faulty, replace with the correct specification module. Re-flash the BIOS if corruption is suspected.

    Ethernet communication is lost intermittently

    Check the Ethernet cable and RJ45 connector for physical damage or loose seating. Verify the IP configuration in Windows Network Settings. Monitor the link LED on the Ethernet port during operation.

    Replace the Ethernet cable with a shielded industrial-grade cable. Assign a static IP address to avoid DHCP-related dropouts. If the onboard NIC is faulty, install a compatible PCI Ethernet card as a replacement.

    HMI runtime software crashes repeatedly

    Check the Windows Event Viewer for application error logs. Verify available disk space on the storage device. Confirm the WinCC or WinCC flexible version is compatible with the installed OS and project.

    Reinstall the HMI runtime software and apply the latest available service packs. Repair or recreate the HMI project file if corruption is detected. Increase virtual memory settings if system RAM is insufficient for the application.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart