Siemens 6AV7611-0AB30-0CG0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AB30-0CG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization applications in automation environments. This unit combines a built-in display with a full PC architecture, enabling advanced process visualization, data acquisition, and control tasks.
The SIMATIC Panel PC 670 6AV7611-0AB30-0CG0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and is based on an x86-compatible processor platform running a Windows-based operating system. It is equipped with multiple communication interfaces including Ethernet (RJ45) and serial ports (RS-232/RS-422/RS-485), enabling integration with SIMATIC S7 PLCs and third-party controllers via standard industrial protocols such as PROFIBUS and MPI. The unit is designed for panel mounting with an IP65-rated front face, providing protection against dust and water ingress in industrial settings.
The SIMATIC Panel PC 670 is widely used in the manufacturing, automotive, food and beverage, and process industries for supervisory control and data acquisition (SCADA), recipe management, and complex HMI visualization tasks. Its PC-based architecture allows the installation of standard Windows software alongside Siemens WinCC or ProTool/Pro RT runtime environments, making it suitable for applications requiring high computational performance and flexible software integration. The robust industrial design and panel-mount form factor make it appropriate for integration into control cabinets and operator stations on the factory floor.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Input/Operating Voltage | 24 V DC |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Communication Interfaces | Ethernet (RJ45), RS-232, RS-422/RS-485, USB |
| Operating System | Windows XP Embedded / Windows 2000 |
| Mounting | Panel mounting |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 1000
- Application error in the Windows operating system or runtime software crash, typically logged in the Windows Event Viewer.
Check the Windows Event Viewer for detailed error information. Reinstall or repair the affected application or WinCC/ProTool runtime software. - Event ID: 7026
- A boot-start or system-start driver failed to load during Windows startup.
Check Device Manager for driver conflicts. Reinstall the appropriate hardware driver or restore the system from a known-good backup image. - BIOS POST Error
- Hardware fault detected during Power-On Self-Test, which may indicate a memory, CPU, or hardware component failure.
Reseat RAM modules and check all internal connections. If the error persists, replace the faulty hardware component or contact Siemens service. - WinCC Runtime Error
- WinCC or ProTool/Pro RT runtime environment fails to start or terminates unexpectedly.
Verify the license dongle is present and valid. Reinstall the runtime software and ensure the correct version is compatible with the project configuration. - Network Connection Lost
- Ethernet communication to the PLC or network is interrupted, causing loss of process data on the HMI.
Check Ethernet cable and switch connections. Verify IP address configuration and ensure the PLC communication driver is correctly configured. - Hard Disk Error
- The internal hard disk or CompactFlash storage device reports read/write errors or is not detected at boot.
Replace the internal hard disk or CompactFlash card with a compatible unit. Restore the operating system and application software from a backup image. - Watchdog Timeout
- The system watchdog timer has triggered a reset due to the operating system or application becoming unresponsive.
Investigate running processes for software hangs. Update or reinstall the runtime application and ensure adequate CPU and memory resources are available.
Frequently Asked Questions
What operating system does the SIMATIC Panel PC 670 6AV7611-0AB30-0CG0 run?
This unit is compatible with Windows XP Embedded and Windows 2000, supporting Siemens WinCC and ProTool/Pro RT visualization software.
What HMI software is compatible with this Panel PC?
The 6AV7611-0AB30-0CG0 supports Siemens WinCC (various versions) and ProTool/Pro RT as the primary HMI runtime environments. Standard Windows-compatible software can also be installed.
What communication interfaces are available on this unit?
The Panel PC 670 provides Ethernet (RJ45), RS-232 serial, RS-422/RS-485 serial, and USB ports, enabling connectivity to SIMATIC S7 PLCs via MPI, PROFIBUS, or Industrial Ethernet.
What is the front panel protection rating of this device?
The front panel of the 6AV7611-0AB30-0CG0 carries an IP65 rating, providing full protection against dust and low-pressure water jets.
Can the internal storage be replaced or upgraded?
Yes, the internal storage medium (hard disk or CompactFlash card) can be replaced. It is recommended to create a system backup image before replacement to restore the operating system and application software.
Troubleshooting
Panel PC does not boot and display remains blank after power on
Check the 24 V DC supply voltage at the power input connector. Verify that the power LED is illuminated and listen for any POST beep codes indicating a hardware fault.
Ensure the 24 V DC supply is within tolerance. Reseat RAM modules and internal connectors. If the unit still fails to boot, the internal power supply board or motherboard may require replacement.
Touchscreen does not respond or is inaccurate
Determine whether the display is functioning but the touch layer is unresponsive, or if the calibration is incorrect. Check the touchscreen controller driver in Windows Device Manager.
Recalibrate the touchscreen using the Windows calibration utility. If the touch layer remains unresponsive, check the internal touchscreen controller cable connections or replace the touchscreen assembly.
WinCC or ProTool runtime fails to connect to the PLC
Verify the communication interface settings (IP address, MPI address, or PROFIBUS address) in the project configuration. Check physical cable connections and confirm the PLC is powered and running.
Correct any mismatched communication parameters in the WinCC or ProTool project. Reinstall the communication driver (e.g., SIMATIC NET) if the interface is not recognized by the software.
System runs slowly or application freezes intermittently
Check CPU and RAM utilization in Windows Task Manager. Inspect the hard disk for errors using Windows disk check utilities. Verify that no unnecessary background processes are consuming resources.
Remove unnecessary startup programs and background services. Replace the hard disk or CompactFlash card if disk errors are found. Consider upgrading RAM if the system is operating near its memory limit.
Display shows distorted image or incorrect colors
Check the display cable connection between the motherboard and the TFT panel. Verify display driver settings in Windows Device Manager and confirm the correct resolution is set.
Reseat the internal display cable. Reinstall the graphics driver. If the TFT panel itself is damaged or shows physical defects, replace the display assembly with a compatible unit.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page