The Siemens 6AV7611-0AB22-0CF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated industrial PC platform, offering a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs on Microsoft Windows XP or Windows 2000, supporting SIMATIC WinCC and ProTool/Pro RT visualization software. The unit provides standard PC interfaces including USB, serial (COM), parallel, and Ethernet ports, and is designed for panel mounting with a protection rating of IP65 on the front face.
The SIMATIC Panel PC 670 is widely used in manufacturing, automotive, chemical, and process industries where a full PC-based HMI platform is required. It is suitable for applications demanding rich visualization, data logging, recipe management, and integration with SIMATIC S7 PLCs via PROFIBUS or Industrial Ethernet. Its fanless or low-maintenance design options make it appropriate for environments where reliability and long service intervals are critical.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Type | TFT LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Protection Rating (Front) | IP65 |
| Protection Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM), Parallel |
| Mounting | Panel mounting |
| Series | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to load correctly during boot.
Check hard disk or CompactFlash integrity. Verify OS installation and boot configuration. Replace storage media if corrupted. - Event ID: 200
- Watchdog timeout — the application software stopped responding within the watchdog monitoring period.
Restart the application. Check for software deadlocks or excessive CPU load. Update or reinstall the HMI runtime software. - Event ID: 300
- Temperature warning — internal system temperature has exceeded the warning threshold.
Check ambient temperature and ventilation around the panel. Clean air vents and ensure the cooling system is functioning. Verify operating environment is within specification. - Event ID: 400
- Power supply undervoltage — the 24 V DC supply voltage has dropped below the minimum operating threshold.
Measure the supply voltage at the power connector. Ensure the power supply unit is rated correctly and check wiring for voltage drop. - Event ID: 500
- Communication error — loss of connection to the PLC or network device.
Check Ethernet or PROFIBUS cabling and connectors. Verify network configuration and IP address settings. Restart communication drivers in WinCC or ProTool/Pro RT. - Event ID: 600
- Hard disk or storage media error — read/write failure detected on the internal storage device.
Run a disk check utility. Back up data immediately. Replace the CompactFlash card or hard disk drive if errors persist. - Event ID: 700
- Touch screen calibration error — touch input is misaligned or unresponsive.
Perform touch screen recalibration via the Windows Control Panel or SIMATIC configuration tool. Clean the touch surface and check the touch controller connection.
Frequently Asked Questions
What operating systems are supported by the SIMATIC Panel PC 670 (6AV7611-0AB22-0CF0)?
The SIMATIC Panel PC 670 supports Microsoft Windows XP Professional and Windows 2000, and is compatible with SIMATIC WinCC and ProTool/Pro RT HMI runtime software.
What is the display size and resolution of this panel PC?
The 6AV7611-0AB22-0CF0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and resistive touch screen input.
What communication interfaces are available on this unit?
The panel PC provides Ethernet (RJ45), USB ports, RS-232 serial (COM) ports, and a parallel port, enabling connectivity to PLCs, networks, and peripheral devices.
What is the front panel protection rating of the 6AV7611-0AB22-0CF0?
The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it resistant to dust and water jets, suitable for industrial panel installations.
Is this Panel PC compatible with Siemens SIMATIC S7 PLCs?
Yes, the SIMATIC Panel PC 670 is designed to integrate with SIMATIC S7-300 and S7-400 PLCs via Industrial Ethernet or PROFIBUS using SIMATIC communication drivers within WinCC or ProTool/Pro RT.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector. Verify the backlight is functioning by shining a light at the screen to detect a faint image. Inspect internal fuse and power supply board.
Restore correct 24 V DC supply. If the backlight has failed, replace the inverter board or the TFT display assembly. If the power supply board is faulty, replace or repair it.
Touch screen does not respond or responds inaccurately
Check if the touch controller is recognized in Windows Device Manager. Attempt touch screen recalibration. Inspect the touch overlay for physical damage or contamination.
Recalibrate the touch screen using the Windows Control Panel calibration tool. Clean the touch surface with a soft cloth. If the touch controller hardware is faulty, replace the touch overlay or controller board.
Panel PC fails to boot or continuously restarts
Check the CompactFlash card or hard disk for errors using a disk diagnostic tool. Verify that the OS installation is intact. Check for overheating by monitoring system temperature.
Replace the CompactFlash card or hard disk and reinstall the operating system and HMI software. Ensure the unit is operating within the specified temperature range and that ventilation is adequate.
Loss of communication with SIMATIC PLC
Verify Ethernet or PROFIBUS cable connections and check for link activity LEDs. Confirm IP address configuration and subnet settings in Windows and WinCC. Check for driver errors in Device Manager.
Correct network configuration settings and replace damaged cables or connectors. Reinstall or update the SIMATIC communication drivers. Ensure the PLC is powered and configured with matching communication parameters.
System clock loses time after power off
The real-time clock (RTC) battery may be depleted. Check the BIOS clock after a power cycle to confirm time loss.
Replace the internal CMOS battery (typically a CR2032 coin cell) on the motherboard. After replacement, reset the system time and date in the BIOS settings.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page