Siemens 6AV7611-0AB22-0AE0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AB22-0AE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. The unit combines a flat-panel display with an integrated industrial PC platform, offering a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7611-0AB22-0AE0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and a touch-sensitive screen for operator interaction. It is equipped with an Intel Celeron processor and runs on Microsoft Windows operating systems, supporting SIMATIC WinCC and other SCADA/HMI software packages. The unit provides standard PC interfaces including USB, serial (RS-232), and Ethernet (RJ45) ports, and is designed for panel mounting with a robust aluminum front bezel rated to IP65 on the front face. The system operates on a 24 V DC supply voltage.
The SIMATIC Panel PC 670 is widely used in manufacturing, automotive, food and beverage, and process industries where a full PC-based HMI platform is required. It is suitable for applications demanding high graphical performance, data logging, and integration with enterprise-level systems via standard Ethernet networking. Its fanless or low-maintenance design options and industrial-grade components make it appropriate for continuous operation in factory floor environments.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| IP Rating (Front) | IP65 |
| Mounting | Panel mounting |
| Communication Interface | Ethernet RJ45, RS-232, USB |
| Operating System | Windows XP / Windows 2000 |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to load correctly during boot.
Check hard disk or CompactFlash card integrity. Verify OS installation and boot configuration in BIOS. - Event ID: 1000
- Application fault — the HMI or SCADA software (e.g. WinCC) has crashed unexpectedly.
Restart the application. Check Windows Event Viewer for detailed error logs. Reinstall HMI software if the issue persists. - Event ID: 7026
- Driver load failure — a hardware driver failed to load during Windows startup.
Check Device Manager for driver conflicts. Reinstall or update the relevant hardware driver. - Communication Error
- Loss of communication between the Panel PC and the connected PLC or automation controller.
Verify Ethernet or serial cable connections. Check IP address configuration and network settings. Confirm PLC is powered and running. - Watchdog Timeout
- The system watchdog timer has triggered, indicating the operating system or application has become unresponsive.
Perform a controlled restart. Investigate CPU load and running processes. Check for software loops or memory leaks in the HMI application. - Temperature Warning
- Internal hardware temperature has exceeded the recommended operating threshold.
Check ambient temperature and ventilation around the panel. Clean air vents and ensure the installation environment is within the 0–50 °C operating range. - Hard Disk / Storage Fault
- Read/write error detected on the internal storage medium (hard disk or CompactFlash).
Back up data immediately. Run a disk check utility. Replace the storage medium if errors persist.
Frequently Asked Questions
What is the supply voltage for the 6AV7611-0AB22-0AE0?
The unit operates on a 24 V DC supply voltage, which is standard for SIMATIC Panel PC 670 devices.
What display size and resolution does this Panel PC have?
The 6AV7611-0AB22-0AE0 features a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA).
Is this Panel PC compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is designed to run SIMATIC WinCC and other PC-based HMI and SCADA software packages under Windows XP or Windows 2000.
What is the front panel protection rating of this unit?
The front panel of the 6AV7611-0AB22-0AE0 is rated to IP65, providing protection against dust and water jets, making it suitable for industrial panel installations.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), RS-232 serial, and USB interfaces for connectivity to PLCs, networks, and peripheral devices.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify the internal fuse and inspect the backlight inverter board for visible damage.
Restore correct supply voltage if out of range. Replace the backlight inverter or the TFT display panel if the backlight has failed. Check and replace the internal fuse if blown.
Touchscreen does not respond or is inaccurate
Check if the touch controller driver is loaded correctly in Windows Device Manager. Verify that the touch calibration has not been corrupted.
Recalibrate the touchscreen using the Windows calibration utility. If the issue persists, reinstall the touch controller driver or replace the touchscreen overlay.
Panel PC fails to boot into Windows
Attempt to boot from an external medium to determine if the fault is with the storage device or the OS installation. Check BIOS settings for correct boot device order.
Restore or reinstall the Windows operating system from a recovery image. Replace the CompactFlash card or hard disk if the storage medium is found to be faulty.
Loss of communication with PLC
Verify physical Ethernet or serial cable connections. Check the IP address configuration in Windows network settings and confirm the PLC is online and reachable.
Correct any IP address conflicts or misconfiguration. Replace faulty cables or connectors. Ensure the correct communication driver and protocol settings are configured in the HMI software.
Unit overheating or shutting down unexpectedly
Check the ambient temperature of the installation environment. Inspect ventilation slots for blockage by dust or debris.
Clean all ventilation openings. Ensure the installation environment does not exceed 50 °C. Verify that the panel cutout provides adequate clearance for heat dissipation as specified in the installation manual.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page