Siemens 6AV7611-0AB20-0BH0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AB20-0BH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface applications, combining computing power with a robust flat-panel display in a single integrated unit. This unit is intended for use as an operator station in industrial automation environments where both visualization and data processing capabilities are required.
The SIMATIC Panel PC 670 (6AV7611-0AB20-0BH0) features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA), providing clear visualization of process data. The unit is based on an x86-compatible processor architecture and supports standard PC operating systems such as Windows XP Professional or Windows 2000, enabling the use of standard SCADA and HMI software packages. It is equipped with multiple communication interfaces including Ethernet (RJ45) and standard PC ports (USB, serial, parallel), and is designed for panel mounting with an IP65-rated front panel for protection against dust and water ingress. The device supports expansion via PCI slots and includes a hard disk drive for data storage and application execution.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine tool industries where a full PC-based HMI solution is required. It is suitable for applications demanding high graphical performance, data logging, and integration with Siemens SIMATIC WinCC or other SCADA software. Industries such as automotive, food and beverage, chemical processing, and packaging commonly deploy this panel PC as a central operator workstation on the production floor.
Technical Specifications
| Display Size | 12.1 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT Color LCD |
| Front Panel Protection | IP65 |
| Operating Voltage | 24 V DC |
| Communication Interface | Ethernet (RJ45), USB, Serial (RS-232), Parallel |
| Operating System | Windows XP Professional / Windows 2000 |
| Storage | Hard disk drive (integrated) |
| Mounting | Panel mounting |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 95% (non-condensing) |
| Series | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk integrity, verify BIOS settings, and ensure the operating system installation is intact. Replace hard disk if drive failure is confirmed. - Event ID: 101
- Hardware watchdog timeout — the system did not respond within the expected time window.
Check CPU load and running processes. Restart the panel PC and investigate any software causing system hangs. Update or reinstall the HMI application if the issue persists. - Event ID: 102
- Fan failure or thermal warning — cooling fan speed below threshold or fan not detected.
Inspect and clean the cooling fan. Replace the fan if it is not operating. Ensure ambient temperature is within the specified operating range. - Event ID: 103
- Battery low warning — the CMOS/RTC backup battery voltage is below the minimum threshold.
Replace the internal CMOS battery (typically CR2032 or equivalent). After replacement, reconfigure BIOS date, time, and settings. - Event ID: 104
- Hard disk error — read/write failure or S.M.A.R.T. warning reported by the storage device.
Back up all data immediately. Run disk diagnostics and replace the hard disk drive if errors are confirmed. Reinstall the operating system and HMI software on the new drive. - Event ID: 105
- Network communication error — Ethernet interface not detected or link failure.
Check Ethernet cable connections and network switch status. Verify network adapter settings in the operating system Device Manager. Replace the Ethernet cable or network adapter if hardware fault is confirmed. - Event ID: 106
- Display or backlight failure — screen remains dark or backlight does not illuminate after power-on.
Check 24 V DC supply voltage at the power connector. Inspect the backlight inverter and display cable connections. Replace the backlight unit or display panel if hardware failure is confirmed. - Event ID: 107
- Memory error — RAM module not detected or parity/ECC error reported during POST.
Reseat the RAM module(s). Test with a known-good memory module. Replace the faulty RAM if the error persists after reseating.
Frequently Asked Questions
What is the supply voltage for the 6AV7611-0AB20-0BH0?
The SIMATIC Panel PC 670 (6AV7611-0AB20-0BH0) operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel devices.
What operating systems are compatible with this Panel PC?
This unit supports Windows XP Professional and Windows 2000, allowing the use of standard industrial HMI and SCADA software such as Siemens SIMATIC WinCC.
What is the front panel protection rating of the 6AV7611-0AB20-0BH0?
The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it resistant to dust and water jets, suitable for industrial environments.
Can this Panel PC be integrated with Siemens SIMATIC WinCC?
Yes, the SIMATIC Panel PC 670 is fully compatible with Siemens SIMATIC WinCC and other standard PC-based HMI software packages, as it runs a standard Windows operating system.
What display size and resolution does the 6AV7611-0AB20-0BH0 provide?
The unit features a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA), providing clear visualization of process graphics and operator interfaces.
Troubleshooting
Panel PC does not power on after switching on the 24 V DC supply
Measure the 24 V DC supply voltage at the power input connector. Check for blown internal fuses and inspect the power supply module for visible damage.
Ensure the supply voltage is within the specified 24 V DC range. Replace any blown fuses with the correct rating. If the internal power supply module is faulty, replace it with a compatible spare.
Display is blank or backlight does not illuminate after power-on
Verify that the unit is receiving power (check status LEDs). Inspect the display cable connection between the mainboard and the display panel. Test the backlight inverter output voltage.
Reseat the display cable connectors. If the backlight inverter is faulty, replace it. If the TFT panel itself is damaged, replace the display assembly with a compatible 12.1-inch SVGA unit.
Touchscreen or mouse input is unresponsive or inaccurate
Check the touchscreen controller connection to the mainboard. In the operating system, navigate to the touchscreen calibration utility and verify calibration settings.
Recalibrate the touchscreen using the built-in calibration tool in Windows. If the touchscreen controller driver is corrupted, reinstall the driver. Replace the touchscreen overlay if physical damage is present.
System boots but HMI application fails to start or crashes repeatedly
Check the Windows Event Viewer for application error logs. Verify that the hard disk has sufficient free space and that no disk errors are present. Confirm that the installed HMI software version is compatible with the operating system.
Run a disk check (chkdsk) to repair file system errors. Reinstall the HMI application if software corruption is detected. If the hard disk is failing, replace it and perform a clean installation of the OS and HMI software.
Ethernet communication is lost or the network interface is not recognized
Check the Ethernet cable and switch port status. Open Device Manager in Windows and verify that the network adapter is listed without errors. Ping the device from another network node to confirm connectivity.
Replace the Ethernet cable if damaged. Reinstall the network adapter driver if it shows an error in Device Manager. If the onboard Ethernet port is physically damaged, use a PCI network adapter card as a replacement if an expansion slot is available.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page