• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AA30-0CH0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AA30-0CH0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AA30-0CH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AA30-0CH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a flat-panel display with a full PC architecture, combining operator interface and computing functions in a single compact device.

    The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is built around an x86-compatible processor platform and runs Microsoft Windows operating systems, supporting SIMATIC WinCC and other Siemens HMI software packages. The unit provides standard PC interfaces including USB, Ethernet (RJ45), and serial ports, and is designed for front-panel mounting with an IP65 protection rating on the front face. Onboard memory and storage options allow for flexible configuration to suit various application requirements.

    The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine tool industries where a robust, integrated PC-based HMI solution is required. Its fanless or low-maintenance design options make it suitable for environments with dust or temperature variations. The device is commonly deployed in applications such as SCADA visualization, production line monitoring, and machine control panels where both computing power and operator interface functionality are needed in a single unit.

    Technical Specifications

    Series/Product Family SIMATIC Panel PC 670
    Display Size 12 inch
    Display Type TFT LCD
    Display Resolution 800 x 600 pixels (SVGA)
    Touch Technology Resistive touchscreen
    Input/Operating Voltage 24 V DC
    IP/Protection Rating IP65 (front panel)
    Operating Temperature 0 °C to 45 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    Communication Interface Ethernet (RJ45), USB, RS-232
    Mounting Panel mounting (front flush)
    Certifications CE, UL
    Operating System Microsoft Windows XP / Windows 2000

    Common Error Codes & System Events

    Event ID: 100
    System startup failure or BIOS POST error during boot sequence
    Check hardware connections, reseat memory modules and expansion cards. Verify BIOS settings and restore defaults if necessary.
    Event ID: 200
    Operating system boot failure or corrupted system partition
    Boot from recovery media and repair or reinstall the operating system. Check hard disk or CompactFlash card for errors using diagnostic tools.
    Event ID: 300
    Touchscreen calibration error or touch input not responding
    Recalibrate the touchscreen via the Windows control panel or SIMATIC touchscreen calibration utility. Check touchscreen controller driver installation.
    Event ID: 400
    Ethernet communication failure or network interface not detected
    Check Ethernet cable and network switch connection. Verify IP address configuration and network driver installation in Device Manager.
    Event ID: 500
    WinCC Runtime communication error with PLC or controller
    Verify PLC connection parameters in WinCC project configuration. Check network connectivity and ensure the correct communication driver is loaded.
    Event ID: 600
    Overtemperature warning — internal temperature exceeds operating threshold
    Check ambient temperature and ensure adequate ventilation around the panel. Clean air vents and verify that cooling components are functioning correctly.
    Event ID: 700
    Hard disk or storage media failure detected
    Back up data immediately if possible. Replace the hard disk drive or CompactFlash storage card and reinstall the operating system and application software.

    Frequently Asked Questions

    What operating systems are supported by the SIMATIC Panel PC 670 (6AV7611-0AA30-0CH0)?

    The SIMATIC Panel PC 670 supports Microsoft Windows XP Professional and Windows 2000, which are the operating systems validated by Siemens for use with SIMATIC WinCC and other HMI software on this platform.

    What is the display size and resolution of this Panel PC?

    The 6AV7611-0AA30-0CH0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA), suitable for detailed process visualization and operator interface applications.

    What is the supply voltage for the SIMATIC Panel PC 670?

    This Panel PC operates on a 24 V DC supply voltage, which is standard for industrial panel-mounted devices in automation environments.

    Is the SIMATIC Panel PC 670 compatible with Siemens WinCC software?

    Yes, the SIMATIC Panel PC 670 is designed to run Siemens SIMATIC WinCC and WinCC flexible HMI software, making it directly compatible with Siemens S7 PLC families via standard communication drivers.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7611-0AA30-0CH0 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for industrial panel installation.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the power input connector. Check the internal fuse and verify that the power LED indicator is active.

    Restore correct supply voltage within the 24 V DC specification. Replace the internal fuse if blown. If the display backlight has failed, the backlight inverter or display assembly may require replacement.

    Touchscreen does not respond or registers incorrect touch positions

    Verify that the touchscreen driver is correctly installed in Windows Device Manager. Attempt to recalibrate the touch panel using the SIMATIC or Windows calibration tool.

    Recalibrate the touchscreen through the control panel calibration utility. If the issue persists, reinstall the touchscreen driver or replace the touchscreen controller board.

    Panel PC fails to boot into the operating system

    Observe the boot sequence for BIOS POST errors. Check the hard disk or CompactFlash card for physical connection and use diagnostic tools to test for storage media errors.

    Repair the operating system using recovery media. If the storage media is faulty, replace the hard disk or CompactFlash card and perform a fresh installation of the OS and application software.

    WinCC Runtime loses communication with the connected PLC

    Check the Ethernet or serial connection between the Panel PC and the PLC. Verify IP address settings, subnet configuration, and that the correct WinCC communication driver is active.

    Correct network configuration parameters in WinCC project settings. Replace faulty cables or network components. Ensure the PLC communication module is operational and accessible on the network.

    Unit reports overtemperature or shuts down unexpectedly

    Check the ambient temperature around the panel installation. Inspect ventilation slots for blockages and verify that any cooling fans are operating correctly.

    Reduce ambient temperature or improve cabinet ventilation. Clean dust from ventilation openings. If internal cooling components have failed, replace the affected fan or thermal management module.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart