Siemens 6AV7611-0AA30-0CF0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AA30-0CF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and rugged solution for process visualization and machine control.
The SIMATIC Panel PC 670 (6AV7611-0AA30-0CF0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and a touch-sensitive screen for operator interaction. It is equipped with an x86-compatible processor and supports Windows-based operating systems, enabling compatibility with standard SCADA and HMI software such as WinCC. The unit provides multiple communication interfaces including Ethernet (RJ45) and serial ports, and is built to withstand industrial conditions with a front panel protection rating of IP65.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building industries where a robust, PC-based HMI solution is required. It is suitable for applications such as production line visualization, batch control, and supervisory control systems. Its compatibility with Siemens SIMATIC software and standard industrial communication protocols makes it a practical choice for integration into existing Siemens automation architectures.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 95% (non-condensing) |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Communication Interface | Ethernet (RJ45), RS-232, RS-422/485 |
| Operating System | Windows XP / Windows 2000 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST.
Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat storage media. Replace storage device if faulty. - Event ID: 200
- Watchdog timeout — the application software failed to respond within the defined watchdog interval.
Restart the application. Check for software hangs or excessive CPU load. Verify watchdog configuration in the HMI software settings. - Event ID: 300
- Fan failure or thermal warning — internal cooling fan has stopped or operating temperature exceeded.
Check and clean the cooling fan. Ensure ambient temperature is within specification (0–50 °C). Replace fan if defective. - Event ID: 400
- Power supply undervoltage — supply voltage dropped below the permissible 24 V DC threshold.
Measure the 24 V DC supply at the power connector. Ensure the power supply unit is rated for the Panel PC load. Check wiring for voltage drop. - Event ID: 500
- Hard disk or storage media error — read/write failure on the internal storage device.
Run a disk check utility. Back up data immediately. Replace the hard disk or CompactFlash card as required. - Event ID: 600
- Communication interface error — loss of connection on Ethernet or serial interface.
Check cable connections and network configuration. Verify IP address settings and subnet mask. Test with a known-good cable and check switch/hub status. - Event ID: 700
- Display backlight failure — screen backlight has failed or brightness is abnormally low.
Check backlight inverter board and backlight lamp connections. Replace the backlight inverter or the display unit if the backlight lamp has reached end of life.
Frequently Asked Questions
What is the supply voltage for the 6AV7611-0AA30-0CF0?
The SIMATIC Panel PC 670 (6AV7611-0AA30-0CF0) operates on a 24 V DC supply voltage. Ensure the power source is stable and within the permissible tolerance range.
What operating system does this Panel PC support?
This unit supports Windows XP Professional and Windows 2000, which are pre-installed or compatible with the hardware platform. It is compatible with Siemens WinCC and other Windows-based HMI/SCADA software.
What is the front panel protection rating of this unit?
The front panel of the 6AV7611-0AA30-0CF0 carries an IP65 protection rating, making it resistant to dust ingress and water jets, suitable for industrial panel mounting environments.
Is this Panel PC compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is designed to run Siemens WinCC and other SIMATIC HMI software packages, as it operates on a standard Windows-based x86 PC platform.
What communication interfaces are available on this unit?
The 6AV7611-0AA30-0CF0 provides Ethernet (RJ45), RS-232, and RS-422/485 serial interfaces, enabling connectivity to PLCs, SCADA systems, and industrial networks.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify that the backlight inverter is receiving power and that the display cable is securely connected internally.
Restore correct 24 V DC supply if undervoltage is detected. If supply is correct, replace the backlight inverter board or the display assembly if the backlight lamp has failed.
Touchscreen does not respond or is inaccurate
Check if the touchscreen controller is recognized in the operating system Device Manager. Determine whether the issue is a calibration problem or a hardware failure by testing touch response across the screen.
Recalibrate the touchscreen using the calibration utility in the Windows control panel. If calibration does not resolve the issue, check the touchscreen ribbon cable connection and replace the touchscreen overlay if damaged.
Panel PC fails to boot or hangs at startup
Check the storage media (hard disk or CompactFlash card) for errors using a bootable diagnostic tool. Verify BIOS settings are correct and that the boot device is properly selected.
Run a disk check and repair utility. If the storage media is faulty, replace the hard disk or CompactFlash card and reinstall the operating system and HMI software.
Loss of communication with PLC or network
Verify Ethernet cable integrity and check the network switch or hub. Confirm IP address, subnet mask, and gateway settings in the operating system network configuration.
Replace the Ethernet cable if faulty. Reconfigure network settings to match the plant network. If the Ethernet port is defective, use a USB-to-Ethernet adapter or replace the network interface card.
Unit overheating or fan running at high speed continuously
Check the ambient temperature around the panel cutout. Inspect the cooling fan for dust blockage or mechanical failure. Monitor CPU load in the operating system task manager.
Clean the cooling fan and ventilation openings with compressed air. Ensure the installation environment does not exceed 50 °C. Replace the cooling fan if it is mechanically worn or not spinning correctly.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page