• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AA30-0BG0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AA30-0BG0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AA30-0BG0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AA30-0BG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a high-performance computing platform with a robust industrial enclosure, providing a complete PC-based HMI solution in a single integrated device.

    The SIMATIC Panel PC 670 (6AV7611-0AA30-0BG0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and is equipped with a resistive touchscreen for operator input. It runs on a standard x86-compatible processor architecture and supports Windows-based operating systems, enabling compatibility with standard SCADA and HMI software packages including Siemens WinCC. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-485), and is designed to meet industrial EMC requirements. The front panel achieves IP65 protection rating, making it resistant to dust and water ingress from the front.

    The SIMATIC Panel PC 670 is widely deployed in manufacturing, process automation, and machine tool industries where a full PC-based visualization platform is required. It is suitable for applications demanding rich graphical displays, data logging, recipe management, and integration with enterprise-level systems. Its panel-mount design and industrial-grade construction make it appropriate for installation in control cabinets and operator stations across automotive, food and beverage, chemical, and general manufacturing sectors.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT color LCD
    Touch Technology Resistive touchscreen
    IP Protection Rating (Front) IP65
    Input Voltage 24 V DC
    Communication Interface Ethernet (RJ45), USB, RS-232, RS-485
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Mounting Panel mounting
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes and System Events

    Event ID: 100000
    Loss of communication to the PLC or controller. The HMI cannot establish or maintain a connection to the configured PLC.
    Check Ethernet or serial cable connections. Verify PLC IP address and communication settings in the HMI project. Ensure the PLC is powered and running.
    Event ID: 110000
    Tag read error. The HMI is unable to read a configured process tag from the connected controller.
    Verify the tag address configured in the HMI project matches the actual PLC data block or memory address. Check communication link integrity.
    Event ID: 120000
    Tag write error. A write operation to a PLC tag has failed.
    Check that the target PLC address is not write-protected. Verify communication connection and confirm the tag address is correctly configured.
    Event ID: 40000
    Runtime software error or crash. The WinCC Runtime or HMI application has encountered an unexpected error.
    Restart the runtime application. Check the Windows event log for detailed error information. Reinstall the runtime software if the issue persists.
    Event ID: 130000
    Overflow of the alarm buffer. The number of pending alarms has exceeded the configured buffer limit.
    Acknowledge and clear existing alarms. Increase the alarm buffer size in the HMI project configuration if recurring.
    Event ID: 50000
    Project loading error. The HMI runtime failed to load the configured project file.
    Verify the project file is present and not corrupted on the storage medium. Re-transfer the project from the engineering station using SIMATIC WinCC.
    Hardware Fault
    System hardware component failure detected, such as a failed storage device or memory error reported by the BIOS/OS.
    Check Windows Device Manager for hardware errors. Inspect the CompactFlash card or hard disk for failures. Replace faulty hardware components as necessary.

    Frequently Asked Questions

    What operating system does the SIMATIC Panel PC 670 (6AV7611-0AA30-0BG0) support?

    The SIMATIC Panel PC 670 is designed to run Windows-based operating systems, typically Windows XP Embedded or Windows 2000, depending on the specific configuration ordered. This allows it to run standard HMI and SCADA software including Siemens WinCC.

    What is the display size and resolution of this unit?

    The 6AV7611-0AA30-0BG0 features a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and a resistive touchscreen for operator interaction.

    What is the front panel protection rating of this Panel PC?

    The front panel of the SIMATIC Panel PC 670 achieves an IP65 protection rating, providing complete protection against dust ingress and resistance to water jets.

    What communication interfaces are available on this Panel PC?

    The unit provides Ethernet (RJ45), USB ports, and serial interfaces (RS-232/RS-485), enabling connectivity to PLCs, network infrastructure, and peripheral devices.

    Is this Panel PC compatible with Siemens WinCC?

    Yes, the SIMATIC Panel PC 670 is designed to be compatible with Siemens WinCC visualization software, as well as other Windows-compatible SCADA and HMI packages.

    Troubleshooting

    Display remains blank after power on

    Check that 24 V DC supply voltage is present at the power connector. Verify the power LED status. Attempt to connect an external monitor via the VGA port to determine if the issue is with the display panel or the PC board.

    If the external monitor shows output, the internal display or backlight inverter may have failed and requires replacement. If no output is present on either display, inspect the power supply and main board for faults.

    Touchscreen does not respond or is inaccurate

    Determine whether the touch input is completely unresponsive or simply misaligned. Check the touchscreen controller driver status in Windows Device Manager.

    Recalibrate the touchscreen using the calibration utility in the Windows Control Panel. If the touchscreen remains unresponsive after recalibration, the resistive touch overlay or its controller board may need replacement.

    Panel PC fails to boot or continuously restarts

    Observe the boot sequence for BIOS error messages. Check the CompactFlash card or hard disk for errors using diagnostic tools. Inspect the Windows event log if the system reaches the OS level before restarting.

    Replace the CompactFlash card or storage device if it is found to be faulty. Reinstall the operating system and HMI software if the storage medium is functional but the OS installation is corrupted.

    Loss of communication with PLC

    Verify the Ethernet or serial cable connections between the Panel PC and the PLC. Check the IP address configuration of both devices and confirm they are on the same network subnet. Ping the PLC from the Panel PC to test basic network connectivity.

    Correct any IP address or subnet mask mismatches. Replace faulty cables or connectors. Verify the PLC communication settings match those configured in the WinCC project.

    HMI runtime application crashes or freezes

    Check available RAM and storage space on the Panel PC. Review the Windows event log and WinCC diagnostic logs for error entries. Determine if the issue is reproducible under specific operating conditions or alarm states.

    Free up storage space and close unnecessary background applications. Update or reinstall the WinCC Runtime software. If hardware memory errors are suspected, test and replace RAM modules as applicable.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart