Siemens 6AV7611-0AA22-0CE0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AA22-0CE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, enabling both operator control and data processing within a single compact device.
The SIMATIC Panel PC 670 (6AV7611-0AA22-0CE0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs on a Windows-based operating system, providing compatibility with standard SCADA and HMI software such as WinCC. The unit offers multiple communication interfaces including Ethernet (RJ45) and serial ports (RS-232), and is built to meet industrial standards for vibration and EMC compliance. The front panel carries an IP65 protection rating, making it resistant to dust and water ingress from the front.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine tool industries where a robust, panel-integrated PC solution is required. Its compatibility with Siemens SIMATIC software and standard industrial protocols makes it suitable for integration into existing Siemens automation architectures. Typical installations include control cabinets, operator stations on production lines, and supervisory control panels in process plants.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Type | TFT LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Touch Technology | Resistive touch screen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Communication Interface | Ethernet (RJ45), RS-232 (COM ports) |
| Operating System | Windows XP / Windows 2000 (factory configurable) |
| Processor | Intel Celeron |
| Mounting | Panel mounting |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to boot correctly, possibly due to a corrupted system partition or failed storage device.
Check the hard disk or CompactFlash card for errors. Attempt a system restore or reinstall the operating system image. - Event ID: 1000
- Application fault — a running HMI or SCADA application (e.g. WinCC) has crashed unexpectedly.
Review the Windows Event Viewer application log for the faulting module. Reinstall or update the affected application. Check for memory or resource conflicts. - Event ID: 7000
- Service failed to start — a required Windows service did not start during boot, which may affect HMI communication or display functions.
Open Services in Windows and verify the affected service is set to Automatic. Restart the service manually or reboot the Panel PC. - Communication Error
- Loss of communication between the Panel PC and the connected PLC or automation controller via Ethernet or serial interface.
Verify network cable connections and IP address configuration. Check firewall settings and ensure the correct communication driver is installed and running. - Watchdog Timeout
- The hardware watchdog timer has triggered a system reset due to the operating system or application becoming unresponsive.
Investigate the root cause of the system hang — check CPU load, memory usage, and application stability. Update drivers or reduce background processes. - Temperature Warning
- Internal temperature of the Panel PC has exceeded the recommended operating threshold.
Check that ventilation slots are not blocked. Verify ambient temperature is within the 0–45 °C operating range. Clean any dust from internal fans or heat sinks if accessible. - Display Backlight Failure
- The TFT display backlight has failed or degraded significantly, resulting in a dim or completely dark screen.
Replace the CCFL backlight lamp or the inverter board. If the display assembly is sealed, replace the complete display unit. - Hard Disk / Storage Error
- The internal hard disk or CompactFlash storage device has reported read/write errors or is not detected by the BIOS.
Run a disk diagnostic utility. Replace the hard disk or CompactFlash card and restore the system image from a backup.
Frequently Asked Questions
What is the supply voltage for the 6AV7611-0AA22-0CE0?
The SIMATIC Panel PC 670 (6AV7611-0AA22-0CE0) operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel devices.
What is the front panel protection rating of this Panel PC?
The front panel of the 6AV7611-0AA22-0CE0 carries an IP65 protection rating, providing full protection against dust and resistance to water jets. The rear of the unit is rated IP20.
Is this Panel PC compatible with Siemens WinCC software?
Yes, the SIMATIC Panel PC 670 is designed to run Siemens WinCC and other SIMATIC HMI software packages, as it operates on a Windows-based operating system and supports the required communication drivers.
What communication interfaces are available on this unit?
The 6AV7611-0AA22-0CE0 provides Ethernet (RJ45) and RS-232 serial communication ports, enabling connectivity to PLCs, networks, and peripheral devices.
Can the operating system or storage media be replaced on this Panel PC?
Yes, the hard disk or CompactFlash storage card can be replaced. Siemens provides system restore images for re-imaging the storage media after replacement. It is recommended to use Siemens-approved storage devices to ensure compatibility.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the power input connector. Check whether the power LED is illuminated. Determine if the system is booting but the display backlight has failed, or if the unit is not powering on at all.
If supply voltage is correct and the unit is running but the screen is dark, replace the display backlight or inverter board. If the unit does not power on, inspect internal fuses and the power supply module.
Touch screen does not respond or is inaccurate
Verify that the touch screen driver is correctly installed in the Windows Device Manager. Check for physical damage or contamination on the touch surface. Attempt a touch screen recalibration using the Siemens or Windows calibration utility.
Recalibrate the touch screen via the control panel calibration tool. If the touch screen remains unresponsive, replace the touch screen overlay or the complete display assembly.
Panel PC fails to boot into Windows
Listen for BIOS POST beep codes and observe any error messages on screen during startup. Access the BIOS to verify that the correct boot device (hard disk or CompactFlash) is detected and set as the primary boot device.
If the storage device is detected but Windows fails to load, restore the system image using a Siemens recovery medium. If the storage device is not detected, replace the hard disk or CompactFlash card and reinstall the system image.
Loss of communication with connected PLC
Check the Ethernet cable and switch/hub connections. Verify the IP address configuration of the Panel PC and the PLC are on the same subnet. Confirm that the communication driver (e.g. SIMATIC NET) is running in Windows.
Correct any IP address mismatches. Restart the SIMATIC NET communication service. Replace the Ethernet cable if a physical fault is suspected. Reinstall the communication driver if it is corrupted.
System runs slowly or HMI application freezes
Check CPU and memory utilization in Windows Task Manager. Identify any background processes consuming excessive resources. Check the hard disk for errors using a disk diagnostic tool, as a failing drive can cause significant slowdowns.
Terminate unnecessary background processes and disable non-essential startup programs. Run a disk check and defragmentation. If the hard disk is failing, replace it and restore the system image. Consider upgrading RAM if the installed memory is insufficient for the application.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page