Siemens 6AV7611-0AA22-0BG0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AA22-0BG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates a flat-panel display with a full PC platform, enabling both operator control and data processing within a single device.
The SIMATIC Panel PC 670 (6AV7611-0AA22-0BG0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs on Microsoft Windows operating systems, providing compatibility with standard SCADA and HMI software packages including WinCC and WinCC flexible. The unit offers multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232), and is built to meet industrial requirements with a fanless or low-noise cooling design and a front panel rated to IP65 for protection against dust and water ingress.
The SIMATIC Panel PC 670 is widely deployed in manufacturing automation, process control, and machine tool applications where a robust, panel-integrated PC solution is required. Its compatibility with Siemens SIMATIC software and standard industrial communication protocols makes it suitable for integration into existing SIMATIC S7 PLC environments. Industries such as automotive, food and beverage, chemical processing, and general manufacturing commonly use this device for supervisory control and data visualization at the machine or line level.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touch screen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interfaces | Ethernet (RJ45), USB, RS-232 |
| Operating System | Windows XP / Windows 2000 |
| Processor | Intel Celeron |
| Mounting | Panel mounting |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 1000
- Application error in the HMI runtime software, typically WinCC or WinCC flexible runtime has encountered an unexpected fault.
Restart the HMI runtime application. Check the Windows event log for detailed error information and verify the project configuration for corrupted tags or scripts. - Event ID: 100
- Communication connection to the PLC has been lost or cannot be established.
Check Ethernet or serial cable connections between the Panel PC and the PLC. Verify IP address settings and PLC communication parameters. Restart the runtime if the connection is not restored automatically. - Event ID: 10000
- The HMI device could not load the project file, possibly due to a corrupted project or incompatible software version.
Re-transfer the project from the engineering station using WinCC flexible or WinCC. Ensure the runtime software version matches the project version. - Hardware Fault: No Display Output
- The display remains blank or shows no image after power-on, indicating a possible backlight or display driver failure.
Check the 24 V DC supply voltage at the power connector. Inspect the display backlight inverter and replace the backlight or display assembly if the backlight has failed. - Watchdog Timeout
- The system watchdog has triggered a reset due to the operating system or application becoming unresponsive.
Check for excessive CPU load or memory usage. Ensure no background processes are consuming excessive resources. Consider reinstalling the operating system image if the problem persists. - Fan/Thermal Warning
- Internal temperature has exceeded the recommended operating threshold, triggering a thermal warning.
Check that the panel cutout ventilation clearances are maintained. Clean any dust from ventilation slots. Verify the ambient temperature is within the 0 °C to 45 °C operating range. - Hard Disk Error
- The internal hard disk or Compact Flash storage device has reported a read/write error or is not detected.
Back up all data immediately. Replace the internal hard disk or Compact Flash card with a compatible unit and restore the operating system image and project files.
Frequently Asked Questions
What is the supply voltage for the Siemens 6AV7611-0AA22-0BG0?
The SIMATIC Panel PC 670 (6AV7611-0AA22-0BG0) operates on a 24 V DC supply voltage, which is standard for SIMATIC industrial panel devices.
What HMI software is compatible with this Panel PC?
This Panel PC is compatible with Siemens WinCC and WinCC flexible HMI software, as well as other standard Windows-based SCADA and visualization packages, since it runs a full Windows operating system.
What is the front panel protection rating of the 6AV7611-0AA22-0BG0?
The front panel of the SIMATIC Panel PC 670 is rated to IP65, providing protection against dust ingress and low-pressure water jets.
Can this Panel PC communicate directly with Siemens S7 PLCs?
Yes, the Panel PC 670 supports Ethernet-based communication and can connect to SIMATIC S7-300 and S7-400 PLCs using standard SIMATIC NET communication drivers included with WinCC or WinCC flexible.
What display size and resolution does the 6AV7611-0AA22-0BG0 have?
This unit features a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and resistive touch screen input.
Troubleshooting
Display is blank or backlight does not illuminate after power-on
Measure the 24 V DC supply voltage at the power input connector. Check whether the power LED indicator is active. If power is confirmed, the backlight inverter or backlight lamp may have failed.
Replace the display backlight or the complete display assembly. Ensure the 24 V DC supply is stable and within tolerance before replacing components.
Touch screen input is not responding or is misaligned
Attempt to access the system via an external USB keyboard or mouse to determine if the operating system is running. Check if the touch driver is loaded correctly in Windows Device Manager.
Recalibrate the touch screen using the Windows touch calibration utility. If calibration does not resolve the issue, reinstall the touch screen driver or replace the touch screen overlay.
Panel PC fails to boot or continuously restarts
Check the Windows event log for critical errors if the system partially boots. Inspect the hard disk or Compact Flash card for errors using a disk diagnostic tool. Verify that the 24 V DC supply is stable under load.
Replace the internal storage device (hard disk or Compact Flash) and restore the operating system image. If the power supply is unstable, inspect and replace the power supply unit.
Loss of communication with the PLC during operation
Check the Ethernet cable connection and verify the IP address configuration of both the Panel PC and the PLC. Use the Windows ping utility to test network connectivity.
Replace the Ethernet cable if faulty. Reconfigure the IP address settings if there is an address conflict. Restart the WinCC or WinCC flexible runtime to re-establish the communication connection.
Operating system loads slowly or application performance is degraded
Check CPU and memory utilization in Windows Task Manager. Inspect the hard disk for fragmentation or errors. Verify that no unnecessary background applications are running.
Perform a disk cleanup and defragmentation. Remove unnecessary startup programs. If the hard disk is failing, replace it with a compatible unit and restore the system image.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page