
Siemens 6AV7611-0AA22-0AH0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AA22-0AH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface applications, combining a built-in display with a full PC architecture running a Windows-based operating system. This unit is intended for use as an operator station in industrial automation environments where both visualization and computing power are required.
The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and is equipped with a touch-sensitive screen for operator interaction. It is built around an industrial-grade processor with integrated RAM and supports compact flash or hard disk storage options. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces, enabling integration with SIMATIC S7 PLCs and other automation systems via PROFIBUS or Industrial Ethernet. The enclosure is rated to IP65 at the front panel, providing protection against dust and water ingress in industrial environments.
The SIMATIC Panel PC 670 is widely used in manufacturing, automotive, food and beverage, and process industries where a full PC-based HMI solution is required at the machine level. Its rugged construction and industrial-grade components make it suitable for installation in control cabinets and machine panels exposed to vibration, temperature variation, and electromagnetic interference. The unit is commonly used to run SIMATIC WinCC or WinCC flexible visualization software for process monitoring and control.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| Front Panel Protection | IP65 |
| Rear Protection | IP20 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Communication Interface | Ethernet (RJ45), USB, Serial (RS-232) |
| Operating System | Windows XP Embedded |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or compact flash card integrity. Verify BIOS settings and re-seat storage media. Replace storage device if corrupted. - Event ID: 200
- Touchscreen calibration error or touch input not responding correctly.
Recalibrate the touchscreen via the Windows control panel or SIMATIC touchscreen calibration utility. If persistent, check touchscreen controller connection internally. - Event ID: 300
- Ethernet communication failure or network interface not detected.
Check Ethernet cable and network switch connection. Verify IP address configuration in Windows network settings. Replace Ethernet cable or check RJ45 port for damage. - Event ID: 400
- Fan failure or thermal warning — internal temperature exceeding operating threshold.
Check and clean ventilation slots. Verify ambient temperature is within specification. Inspect internal fan operation and replace if faulty. - Event ID: 500
- WinCC Runtime communication error with PLC or SCADA system.
Verify PLC connection settings in WinCC project. Check PROFIBUS or Ethernet cabling. Confirm PLC is online and communication parameters match. - Event ID: 600
- Hard disk or compact flash storage device failure or read/write error.
Run disk diagnostics. Back up project data immediately. Replace hard disk or compact flash card with a compatible industrial-grade replacement. - Event ID: 700
- Power supply undervoltage — 24 V DC supply outside acceptable range.
Measure 24 V DC supply at the power connector. Ensure supply voltage is within 20.4 V to 28.8 V DC. Replace or adjust the power supply unit as needed.
Frequently Asked Questions
What operating system does the SIMATIC Panel PC 670 (6AV7611-0AA22-0AH0) run?
This unit runs Windows XP Embedded, which is pre-installed and optimized for industrial HMI applications. It supports SIMATIC WinCC and WinCC flexible visualization software.
What is the display size and resolution of this Panel PC?
The 6AV7611-0AA22-0AH0 features a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and a resistive touchscreen for operator input.
What is the supply voltage for this Panel PC?
The unit operates on a 24 V DC supply voltage, which is standard for SIMATIC panel-mounted devices in industrial control cabinet installations.
What communication interfaces are available on this unit?
The Panel PC 670 provides Ethernet (RJ45), USB ports, and serial RS-232 interfaces, supporting connectivity to SIMATIC S7 PLCs via Industrial Ethernet or PROFIBUS adapters.
What is the front panel protection rating of this Panel PC?
The front panel of the 6AV7611-0AA22-0AH0 is rated IP65, providing full protection against dust ingress and protection against low-pressure water jets.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector using a multimeter. Verify the supply is within the 20.4 V to 28.8 V DC range. Check internal fuse and power supply board.
Restore correct supply voltage. Replace the internal fuse if blown. If the backlight is faulty, the backlight inverter or TFT display assembly may need replacement.
Touchscreen does not respond or registers incorrect touch positions
Attempt touchscreen recalibration through the Windows control panel. Check for physical damage or contamination on the screen surface that may interfere with resistive touch detection.
Recalibrate the touchscreen using the SIMATIC calibration utility. Clean the screen surface. If calibration fails repeatedly, the touchscreen overlay may need replacement.
Unit fails to boot or Windows does not start
Listen for hard disk activity during startup. Access BIOS to check if the storage device is detected. Test the compact flash card or hard disk in another system if possible.
Replace the compact flash card or hard disk with a compatible industrial-grade unit. Reinstall the Windows XP Embedded image and WinCC software from backup or recovery media.
Ethernet communication to PLC is lost intermittently
Check Ethernet cable condition and connector seating. Verify IP address and subnet mask settings in Windows. Check for IP address conflicts on the network.
Replace the Ethernet cable. Assign a static IP address to avoid conflicts. Update network adapter drivers if available and verify switch port configuration.
Unit overheats and shuts down unexpectedly
Check ambient temperature around the panel installation. Inspect ventilation slots for dust blockage. Verify the internal cooling fan is operational.
Clean all ventilation slots with compressed air. Ensure ambient temperature does not exceed 45 °C. Replace the internal fan if it is not spinning or is noisy.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page


