Siemens 6AV7611-0AA12-0CH0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AA12-0CH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and rugged solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7611-0AA12-0CH0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports 65,536 colors. It is equipped with an Intel Celeron processor and runs on a Windows-based operating system, providing compatibility with standard SCADA and HMI software packages including SIMATIC WinCC. The unit includes standard PC interfaces such as USB, serial (RS-232), parallel, and Ethernet ports, enabling flexible integration into existing automation networks. The front panel is rated IP65 for protection against dust and water ingress, making it suitable for installation in control cabinet doors.
The SIMATIC Panel PC 670 is widely used in manufacturing, process industries, and machine building where a robust, panel-mounted PC with visualization capability is required. Its compatibility with Siemens SIMATIC software and standard industrial communication protocols makes it well suited for integration into SIMATIC S7 PLC environments. Typical applications include process monitoring stations, machine control panels, and supervisory control interfaces in industries such as automotive, food and beverage, chemical, and water treatment.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Colors | 65,536 colors |
| Display Type | TFT LCD |
| Input/Operating Voltage | 24 V DC |
| Front Protection Rating | IP65 |
| Rear Protection Rating | IP20 |
| Communication Interface | Ethernet (RJ45), RS-232, USB, Parallel |
| Operating System | Windows XP / Windows 2000 (factory configurable) |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to initialize correctly during boot.
Check the hard disk or CompactFlash card for integrity. Verify the OS installation and re-image if necessary. - Event ID: 101
- Hardware configuration mismatch — installed hardware does not match the expected system configuration.
Check BIOS settings and verify that all hardware components are correctly seated and recognized. - Event ID: 200
- Communication interface error — loss of communication on the Ethernet or serial interface.
Check cable connections, verify network settings, and confirm the communication driver is correctly configured in the OS. - Event ID: 201
- WinCC Runtime connection lost — the HMI application has lost its connection to the PLC or data source.
Verify PLC communication settings, check Ethernet cabling, and restart the WinCC Runtime application. - Event ID: 300
- Touchscreen or input device not responding — the front panel input device has stopped responding.
Recalibrate the touchscreen via the control panel utility. If the issue persists, check the internal touchscreen controller connection. - Event ID: 400
- Fan failure or overtemperature warning — internal cooling fan has failed or ambient temperature exceeds the rated limit.
Check and clean the ventilation slots. Verify ambient temperature is within 0 °C to +45 °C. Replace the cooling fan if faulty. - Event ID: 500
- Storage media error — read/write error detected on the hard disk or CompactFlash storage device.
Run a disk check utility. Back up data immediately and replace the storage medium if errors persist. - Event ID: 600
- Power supply undervoltage — the 24 V DC supply voltage has dropped below the acceptable operating threshold.
Measure the supply voltage at the power connector. Ensure the supply is stable and within the specified 24 V DC range.
Frequently Asked Questions
What is the supply voltage for the 6AV7611-0AA12-0CH0?
The SIMATIC Panel PC 670 (6AV7611-0AA12-0CH0) operates on a 24 V DC supply voltage.
What display size and resolution does this Panel PC have?
This unit features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and 65,536 colors.
Is this Panel PC compatible with Siemens SIMATIC WinCC?
Yes, the SIMATIC Panel PC 670 is compatible with SIMATIC WinCC and other standard Siemens HMI software packages, as it runs a Windows-based operating system.
What is the front panel protection rating of the 6AV7611-0AA12-0CH0?
The front panel of this unit is rated IP65, providing full protection against dust and water jets, making it suitable for installation in control cabinet doors.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), RS-232 serial, USB, and parallel interfaces for connectivity to PLCs, networks, and peripheral devices.
Troubleshooting
Display remains blank after power on
Measure the 24 V DC supply voltage at the power connector. Check whether the power LED is illuminated and listen for fan activity to determine if the unit is receiving power.
Verify and restore the 24 V DC supply. If power is confirmed but the display remains blank, check the internal display cable connection or replace the backlight inverter board.
Touchscreen does not respond to input
Attempt to control the system using an external USB mouse or keyboard to determine if the issue is isolated to the touchscreen. Check Device Manager in Windows for touchscreen controller errors.
Recalibrate the touchscreen using the calibration utility in the Windows Control Panel. If calibration fails, check the internal ribbon cable connection to the touchscreen controller or replace the touchscreen assembly.
Unit fails to boot into Windows operating system
Observe the boot sequence on the display. Check whether the BIOS POST completes and whether the system attempts to load from the storage device. Listen for hard disk activity.
Re-seat the CompactFlash card or hard disk. If the storage medium is corrupted, re-image the device using the Siemens recovery image for the Panel PC 670. Replace the storage medium if hardware failure is confirmed.
Loss of communication with SIMATIC S7 PLC
Verify the Ethernet cable connection between the Panel PC and the PLC or network switch. Check the IP address configuration in Windows and confirm the WinCC project communication settings match the PLC configuration.
Restore correct IP addressing, check and replace the Ethernet cable if faulty, and restart the WinCC Runtime. Ensure the correct SIMATIC communication driver is installed and active.
System overheating or unexpected shutdown
Check the ambient temperature around the panel installation. Inspect the ventilation slots on the rear of the unit for blockage by dust or debris. Verify that the internal cooling fan is operating.
Clean all ventilation slots with compressed air. Ensure the installation environment does not exceed 45 °C. Replace the internal cooling fan if it is found to be faulty or not spinning.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page