• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AA11-0CF0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AA11-0CF0 SIMATIC Panel PC 670

    € 2.133,00

    Reset
    Clear
    SKU: 6AV7611-0AA11-0CF0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AA11-0CF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial automation environments. This unit integrates a flat-panel display with a full PC platform, providing both operator interface and computing functionality in a single device.

    The SIMATIC Panel PC 670 (6AV7611-0AA11-0CF0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports 65,536 colors. It is built around an x86-compatible processor platform and is equipped with interfaces including USB, serial (RS-232), and parallel ports, as well as an Ethernet interface for network connectivity. The unit is designed for front-panel mounting with an IP65-rated front bezel, providing protection against dust and water ingress in industrial settings. It supports operation with standard Windows-based operating systems, enabling compatibility with a wide range of SCADA and HMI software packages including Siemens WinCC.

    The SIMATIC Panel PC 670 is used extensively in manufacturing, process automation, and machine tool industries where a robust, panel-integrated PC solution is required. Its sealed front panel makes it suitable for installation in control cabinets and operator stations exposed to harsh environmental conditions. The device is commonly deployed in automotive production lines, chemical processing plants, and packaging machinery where reliable visualization and data processing are essential.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Colors 65,536 colors
    Display Type TFT LCD
    Input/Operating Voltage 24 V DC
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 95% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Communication Interface Ethernet (RJ45), RS-232, USB, Parallel
    Mounting Panel mounting (portrait/landscape)
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    System startup error — the operating system failed to boot correctly or a critical system file is missing.
    Check hard disk or CompactFlash integrity. Reinstall or restore the operating system image. Verify BIOS settings are correct.
    Event ID: 1000
    Application fault — a software application has crashed or become unresponsive.
    Restart the affected application. Check Windows Event Viewer for detailed error logs. Update or reinstall the HMI software if the fault persists.
    Event ID: 7000
    Service control manager error — a required Windows service failed to start during boot.
    Check Windows Event Viewer for the specific service name. Ensure all required drivers and services are correctly installed and configured.
    Hardware Watchdog Timeout
    The hardware watchdog timer has triggered, indicating the system became unresponsive and was automatically reset.
    Investigate the cause of the system hang. Check CPU load, memory usage, and application stability. Update drivers or operating system patches as needed.
    Fan Failure Warning
    The internal cooling fan has failed or is operating below the minimum required speed.
    Replace the internal cooling fan. Ensure adequate ventilation around the panel PC. Check that air vents are not blocked.
    Temperature Warning
    The internal temperature of the unit has exceeded the permissible operating threshold.
    Check ambient temperature and ensure it is within the 0 °C to +45 °C operating range. Clean air vents and verify fan operation. Reduce heat load if possible.
    Battery Low Warning
    The CMOS/RTC backup battery voltage is low, which may cause loss of BIOS settings and real-time clock data.
    Replace the internal CMOS battery (typically a CR2032 lithium coin cell). After replacement, reconfigure BIOS settings and synchronize the system clock.

    Frequently Asked Questions

    What operating systems are compatible with the SIMATIC Panel PC 670 (6AV7611-0AA11-0CF0)?

    The SIMATIC Panel PC 670 supports Windows-based operating systems including Windows XP Professional and Windows 2000, which were the primary supported platforms for this generation of Panel PC. Compatibility with Siemens WinCC and other SCADA software is supported under these operating systems.

    What is the supply voltage for the 6AV7611-0AA11-0CF0?

    The unit operates on a 24 V DC supply voltage, which is standard for industrial panel-mounted devices in this series.

    What is the front panel protection rating of the 6AV7611-0AA11-0CF0?

    The front panel of the SIMATIC Panel PC 670 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for installation in industrial control cabinets.

    Does the 6AV7611-0AA11-0CF0 support touch input?

    The base variant of the SIMATIC Panel PC 670 with this part number is typically configured with a touchscreen interface; however, the exact touch technology (resistive) should be verified against the specific hardware configuration supplied with the unit.

    What communication interfaces are available on this Panel PC?

    The 6AV7611-0AA11-0CF0 provides Ethernet (RJ45), RS-232 serial, USB, and parallel ports, enabling connectivity to PLCs, networks, and peripheral devices.

    Troubleshooting

    Display remains blank after power is applied

    Check that the 24 V DC supply voltage is present and within tolerance at the power input connector. Verify that the backlight inverter and display cable connections are secure internally.

    Restore correct supply voltage if out of range. If voltage is correct, the backlight or inverter board may have failed and should be replaced. A qualified technician should inspect internal display connections.

    System fails to boot or continuously restarts

    Check the CompactFlash card or hard disk drive for errors using diagnostic tools. Inspect BIOS settings to confirm the correct boot device is selected. Review Windows Event Viewer logs if the system partially boots.

    Replace the CompactFlash card or hard disk if found to be faulty. Restore the operating system image from a known-good backup. Reset BIOS to default settings if configuration has been corrupted.

    Touchscreen input is unresponsive or inaccurate

    Check whether the touchscreen controller driver is correctly installed and active in Device Manager. Determine if the issue is present across the entire screen or only in specific areas, which may indicate physical damage to the touch surface.

    Recalibrate the touchscreen using the calibration utility in the operating system or SIMATIC software. Reinstall the touchscreen driver if it is missing or corrupted. Replace the touchscreen overlay if physical damage is confirmed.

    Ethernet communication is not established

    Verify physical connection of the RJ45 cable and check link indicator LEDs on the port. Confirm network settings (IP address, subnet mask) are correctly configured in the operating system. Check for driver issues in Device Manager.

    Replace the Ethernet cable if faulty. Reconfigure network settings to match the plant network requirements. Reinstall the network adapter driver if it is shown as faulty in Device Manager.

    System clock loses time or BIOS settings reset after power off

    This symptom indicates that the internal CMOS backup battery has discharged or failed. The battery maintains BIOS settings and the real-time clock when main power is removed.

    Replace the internal CMOS battery (typically a CR2032 lithium coin cell). After replacement, re-enter BIOS settings and synchronize the system clock with the plant network time server or manually set the correct time.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart