
Siemens 6AV7611-0AA10-0AH0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AA10-0AH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, enabling advanced process visualization, data acquisition, and control functions.
The SIMATIC Panel PC 670 (6AV7611-0AA10-0AH0) features a 10.4-inch TFT color display and is built around an industrial-grade PC platform running a Windows-based operating system. It supports standard PC interfaces including USB and Ethernet, enabling integration with SIMATIC WinCC and other Siemens SCADA and HMI software packages. The unit is designed for panel mounting and provides a fanless or low-maintenance design suited to continuous industrial operation, with robust construction to withstand vibration and electrical noise typical of factory environments.
The SIMATIC Panel PC 670 is widely deployed in manufacturing, process automation, and machine tool industries where a full PC-based HMI solution is required. It is suitable for applications demanding rich graphical visualization, recipe management, data logging, and connectivity to SIMATIC S7 PLCs via PROFIBUS or Industrial Ethernet. Its panel-mount form factor makes it appropriate for integration into control cabinets and operator stations across automotive, chemical, food and beverage, and general industrial sectors.
Technical Specifications
| Display Size | 10.4 inch |
|---|---|
| Display Type | TFT Color LCD |
| Display Resolution | 640 x 480 (VGA) |
| Display Colors | 256 colors |
| Input/Operating Voltage | 24 V DC |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 95% (non-condensing) |
| IP/Protection Rating | IP65 (front panel) |
| Mounting | Panel mounting |
| Communication Interface | Ethernet (RJ45), USB, COM ports |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
| Operating System | Windows XP Embedded / Windows 2000 |
Common Error Codes & System Events
- Event ID: 1000
- Application error – a software application on the Panel PC has encountered a fatal error and terminated unexpectedly.
Check the Windows Event Viewer for details. Restart the application or reinstall the HMI software (e.g., WinCC flexible Runtime). - Event ID: 7000
- Service failed to start – a required Windows service did not start during boot, which may prevent HMI runtime from launching.
Check the Windows Event Viewer under System logs. Verify service dependencies and restart the service manually or reconfigure startup type. - Communication Error
- Loss of communication between the Panel PC and the connected PLC (e.g., SIMATIC S7) via Ethernet or PROFIBUS.
Check network cable connections and IP address configuration. Verify PLC is online and communication driver settings in WinCC are correct. - Watchdog Timeout
- The system watchdog has detected that the operating system or application has stopped responding within the defined time window.
Perform a controlled restart of the Panel PC. Check for software conflicts or excessive CPU load. Update or reinstall the HMI runtime software if the issue persists. - Hardware Error – Storage
- The Compact Flash card or hard disk used as the system storage medium has failed or is not detected.
Power down the unit and reseat or replace the Compact Flash card. Restore the system image from backup. Ensure the storage medium is rated for industrial use. - Display Backlight Failure
- The TFT display backlight has failed or dimmed significantly, resulting in a dark or unreadable screen.
Replace the backlight inverter board or the display assembly. Check the backlight power connector on the main board for secure connection. - Overheat Warning
- Internal temperature sensors have detected that the Panel PC is operating above the rated thermal threshold.
Check that ventilation slots are unobstructed. Verify ambient temperature is within the 0–50 °C operating range. Clean dust from cooling paths and check any internal fans if fitted.
Frequently Asked Questions
What operating system does the 6AV7611-0AA10-0AH0 run?
The SIMATIC Panel PC 670 (6AV7611-0AA10-0AH0) is designed to run Windows XP Embedded or Windows 2000, depending on the configuration ordered. It supports Siemens WinCC and WinCC flexible Runtime for HMI applications.
What is the display size and resolution of this Panel PC?
This unit features a 10.4-inch TFT color display with a resolution of 640 x 480 pixels (VGA). It supports 256 colors.
What communication interfaces are available on this Panel PC?
The 6AV7611-0AA10-0AH0 provides Industrial Ethernet (RJ45), USB ports, and serial COM ports. These interfaces allow connectivity to SIMATIC S7 PLCs, network infrastructure, and peripheral devices.
What is the supply voltage for this Panel PC?
The unit operates on a 24 V DC supply voltage, which is standard for industrial panel-mounted devices in automation environments.
Is this Panel PC compatible with SIMATIC WinCC?
Yes, the SIMATIC Panel PC 670 is compatible with Siemens WinCC and WinCC flexible Runtime software, making it suitable for SCADA and HMI visualization tasks connected to SIMATIC S7 PLCs.
Troubleshooting
Panel PC does not power on after supplying 24 V DC
Measure the 24 V DC supply voltage at the power input connector. Check for blown internal fuses or a faulty power supply module inside the unit.
Verify the supply voltage is stable and within tolerance. Replace any blown fuses with the correct rating. If the internal power supply module is faulty, replace it with a compatible spare.
Display is blank or backlight is not illuminated after power on
Check whether the PC is booting (listen for HDD/CF activity or check status LEDs). Determine if the issue is with the backlight inverter, the display panel itself, or the video output from the mainboard.
Replace the backlight inverter if the display panel is functional but unlit. If no video signal is present, inspect the video cable connection between the mainboard and the display. Replace the display assembly if the panel is physically damaged.
HMI runtime software fails to start or crashes on boot
Boot into Windows and check the Event Viewer for application or system errors. Verify the integrity of the Compact Flash card or storage medium using disk check utilities.
Restore the system image from a known-good backup. Reinstall the WinCC flexible Runtime software. Replace the Compact Flash card if storage errors are detected, using an industrially rated replacement.
Loss of communication with SIMATIC S7 PLC
Check the Ethernet or PROFIBUS cable connections between the Panel PC and the PLC. Verify the IP address settings and communication driver configuration within the WinCC project.
Reconfigure the network settings to match the PLC subnet. Replace faulty cables or connectors. Ensure the correct communication driver (e.g., S7 Ethernet) is installed and active in the HMI runtime configuration.
Touchscreen does not respond or is misaligned
Determine whether the issue is a hardware fault (damaged touch overlay) or a calibration issue by attempting to recalibrate the touchscreen through the Windows control panel or SIMATIC HMI settings.
Recalibrate the touchscreen using the built-in calibration utility. If calibration does not resolve the issue, inspect the touch controller connection. Replace the touch overlay or the complete display assembly if the hardware is damaged.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page



