• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7462-0AG00-0BJ1 SIMATIC Panel PC 477B
    Awaiting product image

    Siemens 6AV7462-0AG00-0BJ1 SIMATIC Panel PC 477B

    € 1.481,00

    Reset
    Clear
    SKU: 6AV7462-0AG00-0BJ1 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7462-0AG00-0BJ1 is a Panel PC belonging to the SIMATIC Panel PC 477B series, manufactured by Siemens as part of their industrial computing portfolio. This unit is a high-performance industrial panel PC designed for demanding visualization and control tasks in automation environments. It integrates computing power with an operator panel in a single rugged housing, making it suitable for use as an HMI station or embedded PC in machine and plant applications.

    The SIMATIC Panel PC 477B features a multi-core processor platform with Windows-based operating system support, enabling it to run SCADA, HMI runtime software such as WinCC, and third-party applications simultaneously. It is equipped with standard PC interfaces including USB ports, Ethernet (RJ45), and optionally PROFIBUS or PROFINET connectivity, allowing seamless integration into Siemens automation networks. The unit supports a wide range of memory configurations and storage options including CompactFlash or hard disk drives, and is built to withstand industrial environments with an IP65-rated front panel for protection against dust and water ingress.

    The SIMATIC Panel PC 477B is widely deployed in the automotive, food and beverage, pharmaceutical, and chemical processing industries where a combination of visualization, data logging, and process control is required at the machine level. Its ability to run standard Windows software alongside Siemens WinCC runtime makes it suitable for complex HMI applications requiring custom reporting, database connectivity, or integration with MES systems. The robust industrial design ensures reliable operation in environments with vibration, temperature variation, and electromagnetic interference.

    Technical Specifications

    Series SIMATIC Panel PC 477B
    Display Size 15 inch
    Display Technology TFT LCD
    Display Resolution 1024 x 768 px (XGA)
    Touch Technology Resistive touchscreen
    IP Protection Rating (Front) IP65
    Input Voltage 24 V DC
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    Communication Interface Ethernet (RJ45), USB, optionally PROFIBUS
    Operating System Windows XP Embedded / Windows 2000
    Mounting Panel mounting
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    Operating system startup failure or boot error detected during POST sequence.
    Check hard disk or CompactFlash card for integrity. Verify BIOS settings and reseat storage media. Replace storage device if corrupted.
    Event ID: 200
    Watchdog timeout triggered, indicating the application or OS became unresponsive.
    Restart the Panel PC. Investigate running applications for memory leaks or deadlocks. Update or reinstall the HMI runtime software.
    Event ID: 300
    Fan failure or thermal warning detected. Internal cooling fan has stopped or is running below threshold speed.
    Inspect and clean the cooling fan. Replace the fan unit if defective. Ensure ambient temperature is within the specified operating range.
    Event ID: 400
    Battery low warning for the real-time clock (RTC) backup battery.
    Replace the internal CMOS/RTC battery with the correct type as specified in the device manual. Reset date and time after replacement.
    Event ID: 500
    Ethernet communication error or network interface not detected.
    Check Ethernet cable and switch port. Verify IP configuration in the operating system. Reinstall network adapter drivers if the interface is not recognized.
    Event ID: 600
    USB device error or unrecognized USB peripheral connected.
    Disconnect and reconnect the USB device. Try an alternative USB port. Ensure the USB device driver is installed within the operating system.
    Event ID: 700
    Hard disk or CompactFlash storage device read/write error.
    Run a disk check utility to identify bad sectors. Back up data immediately and replace the storage device if errors persist.
    Event ID: 800
    Display or backlight failure detected, screen remains dark or shows artifacts.
    Check display cable connections internally. Replace the backlight inverter or LCD panel if the display hardware is confirmed faulty.

    Frequently Asked Questions

    What operating systems are supported by the SIMATIC Panel PC 477B?

    The SIMATIC Panel PC 477B supports Windows XP Embedded and Windows 2000, allowing it to run Siemens WinCC runtime as well as compatible third-party HMI and SCADA software.

    What is the front panel protection rating of the 6AV7462-0AG00-0BJ1?

    The front panel of this unit carries an IP65 protection rating, providing full protection against dust ingress and resistance to water jets.

    Can this Panel PC be integrated into a PROFIBUS network?

    Yes, the SIMATIC Panel PC 477B can be optionally equipped with a PROFIBUS interface card, enabling direct integration into Siemens PROFIBUS DP automation networks.

    What display size and resolution does this unit feature?

    The 6AV7462-0AG00-0BJ1 is equipped with a 15-inch TFT LCD display with a resolution of 1024 x 768 pixels (XGA), with resistive touchscreen input.

    What is the supply voltage for this Panel PC?

    The unit operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs and compatible with typical control cabinet power supplies.

    Troubleshooting

    Panel PC does not boot and display remains blank after power on

    Measure 24 V DC supply voltage at the power input connector. Check internal fuses and verify the power LED status. Attempt to connect an external monitor via VGA to determine if the issue is display-related or system-related.

    If supply voltage is correct and the system does not POST, reseat or replace the CompactFlash card or hard disk. If an external monitor shows output, replace the internal display cable or LCD backlight inverter.

    Touchscreen input is inaccurate or unresponsive

    Check if the touchscreen controller is recognized in the Windows Device Manager. Attempt a touchscreen recalibration using the Siemens or OS-provided calibration utility.

    Recalibrate the touchscreen through the control panel calibration tool. If the issue persists, clean the touchscreen surface and check the internal ribbon cable connection. Replace the touchscreen overlay if hardware damage is confirmed.

    System freezes or restarts unexpectedly during operation

    Check the Windows event log for watchdog timeout or application crash entries. Monitor CPU temperature and fan operation. Verify that the storage device has no bad sectors using a disk check utility.

    Ensure the cooling fan is operational and the ventilation slots are not blocked. Replace the storage device if disk errors are found. Update or reinstall the HMI runtime software if application crashes are the root cause.

    Ethernet communication is lost or the network interface is not detected

    Verify the Ethernet cable and switch port are functional. Check the network adapter status in Windows Device Manager for error flags or missing drivers.

    Reinstall the Ethernet adapter driver from the Siemens recovery media. If the adapter is still not detected, the onboard NIC may be faulty and the unit may require board-level repair or replacement of the network interface card.

    Date and time reset to default after each power cycle

    This indicates the internal RTC backup battery is depleted and no longer maintaining the real-time clock during power-off periods.

    Replace the internal CMOS battery with the correct replacement type as specified in the SIMATIC Panel PC 477B hardware manual. After replacement, set the correct date and time in the BIOS and operating system.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart