• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7462-0AA00-0BJ0 SIMATIC Panel PC 477B
    Awaiting product image

    Siemens 6AV7462-0AA00-0BJ0 SIMATIC Panel PC 477B

    € 1.972,00

    Reset
    Clear
    SKU: 6AV7462-0AA00-0BJ0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7462-0AA00-0BJ0 is a Panel PC belonging to the SIMATIC Panel PC 477B series, manufactured by Siemens as part of their industrial computing platform for human-machine interface applications. This unit is a compact, fanless industrial Panel PC designed for demanding production environments where reliable visualization and control are required. It integrates computing power and HMI functionality into a single ruggedized housing suitable for panel mounting.

    The SIMATIC Panel PC 477B features an Intel Celeron processor and runs Microsoft Windows XP Embedded or Windows CE, providing a stable platform for SCADA and HMI software such as WinCC flexible or SIMATIC WinCC. It is equipped with onboard Ethernet (RJ45) and USB interfaces for connectivity to controllers and peripherals, along with a CompactFlash card slot for non-volatile storage. The unit is built to withstand industrial environments, with a wide operating temperature range and protection against dust and moisture on the front panel.

    The 6AV7462-0AA00-0BJ0 is widely used in manufacturing automation, process control, and machine tool applications where a robust, integrated Panel PC solution is required. It is suitable for industries such as automotive, food and beverage, chemical processing, and general factory automation. The combination of industrial-grade hardware and compatibility with Siemens SIMATIC software makes it a practical choice for system integrators building centralized HMI and visualization stations.

    Technical Specifications

    Series SIMATIC Panel PC 477B
    Display Size 15 inch
    Display Technology TFT LCD
    Display Resolution 1024 x 768 px (XGA)
    Touch Technology Resistive touchscreen
    Processor Intel Celeron M
    Input/Operating Voltage 24 V DC
    Power Consumption Approx. 60 W
    Communication Interface Ethernet RJ45, USB 2.0, RS-232
    Storage CompactFlash card slot
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    IP Rating (Front) IP65
    Mounting Panel mounting
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    Operating system startup failure or boot error detected during POST.
    Check CompactFlash card integrity and reseat it. Verify the OS image is intact. Replace the CompactFlash card if corrupted.
    Event ID: 200
    Ethernet communication link failure; no network connection detected.
    Check Ethernet cable and switch port. Verify IP configuration in Windows network settings. Replace cable or network switch port if faulty.
    Event ID: 300
    Touchscreen calibration error; touch input not responding correctly.
    Re-run the touchscreen calibration utility from the Windows control panel. Clean the touch surface. If persistent, check the touch controller ribbon cable connection.
    Event ID: 400
    Power supply undervoltage detected; supply voltage below acceptable threshold.
    Measure the 24 V DC supply at the power connector. Ensure supply voltage is within 20.4–28.8 V DC. Replace or adjust the power supply as needed.
    Event ID: 500
    Internal temperature warning; processor or system temperature exceeds normal operating range.
    Check ambient temperature and ensure adequate ventilation around the panel. Verify that the panel cutout dimensions allow sufficient airflow. Clean any dust from ventilation areas.
    Event ID: 600
    USB device not recognized or USB communication error.
    Disconnect and reconnect the USB device. Try an alternative USB port. Check device driver installation in Windows Device Manager.
    Event ID: 700
    WinCC flexible runtime communication error with PLC or controller.
    Verify the communication settings (IP address, MPI/PROFIBUS address) in WinCC flexible. Check physical connection to the PLC. Restart the runtime application.

    Frequently Asked Questions

    What operating system does the 6AV7462-0AA00-0BJ0 run?

    The SIMATIC Panel PC 477B 6AV7462-0AA00-0BJ0 runs Microsoft Windows XP Embedded, providing compatibility with Siemens SIMATIC WinCC flexible and other standard HMI software packages.

    What is the supply voltage for this Panel PC?

    The unit operates on a 24 V DC supply voltage, which is standard for Siemens SIMATIC Panel PC products used in industrial cabinet installations.

    Is this Panel PC compatible with Siemens SIMATIC WinCC flexible?

    Yes, the SIMATIC Panel PC 477B is fully compatible with Siemens SIMATIC WinCC flexible and WinCC runtime software, making it suitable for use as a visualization station in SIMATIC automation systems.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7462-0AA00-0BJ0 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets.

    What storage medium does this Panel PC use?

    The unit uses a CompactFlash card as its primary non-volatile storage medium for the operating system and application data, which can be replaced or upgraded as needed.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the power connector. Check whether the power LED is illuminated. Determine if the system is booting but the display backlight has failed.

    Verify and correct the 24 V DC supply. If the supply is correct and the system appears to boot (HDD activity), replace the backlight inverter or LCD panel. If no boot activity, check the CompactFlash card and reseat it.

    Touchscreen does not respond to input

    Check whether the display image is correct but touch input is unresponsive. Verify the touch controller is recognized in Windows Device Manager. Inspect the touch controller ribbon cable connection internally.

    Recalibrate the touchscreen using the Windows control panel calibration utility. If unresponsive after calibration, reseat the touch controller ribbon cable. Replace the touchscreen assembly if the controller is faulty.

    Unit fails to boot or continuously restarts

    Observe the boot sequence on the display. Check if a POST error message is displayed. Remove and inspect the CompactFlash card for physical damage or corruption.

    Replace the CompactFlash card with a new card and restore the OS image using a Siemens recovery image. If the problem persists after card replacement, inspect the mainboard for damage.

    Ethernet communication not working

    Check the Ethernet link LED on the RJ45 port. Verify the IP address configuration in Windows network settings. Test with a known-good cable and switch port.

    Replace the Ethernet cable and verify switch port functionality. Reconfigure the IP address settings if incorrect. If the link LED does not illuminate with a known-good cable, the onboard Ethernet controller may be faulty and require mainboard replacement.

    WinCC flexible runtime loses connection to PLC

    Check the physical Ethernet or MPI/PROFIBUS connection between the Panel PC and the PLC. Verify communication parameters (IP address, rack/slot number) in the WinCC flexible project settings.

    Correct any mismatched communication parameters in the WinCC flexible project. Ensure the PLC is in RUN mode and reachable on the network. Restart the WinCC flexible runtime application and re-establish the connection.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart