• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7260-1DP30-0BX6 SIMATIC IPC277D
    Awaiting product image

    Siemens 6AV7260-1DP30-0BX6 SIMATIC IPC277D

    € 1.995,00

    Reset
    Clear
    SKU: 6AV7260-1DP30-0BX6 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7260-1DP30-0BX6 is a Panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial PC product line designed for demanding automation and process visualization environments. This unit is a 15-inch multi-touch Panel PC that integrates computing performance with a robust industrial-grade enclosure, suitable for direct panel mounting. It is engineered to operate reliably in harsh industrial conditions where standard commercial hardware would be inadequate.

    The IPC277D features a 15-inch widescreen TFT display with a projected capacitive (PCT) multi-touch interface, supporting up to 5 simultaneous touch points for intuitive operator interaction. The unit is based on an Intel Atom processor platform and supports Windows Embedded Standard 7 or Windows 7 operating systems, providing a familiar environment for SCADA and HMI software deployment. Communication interfaces include Ethernet (RJ45), USB ports, and optional PROFINET connectivity, enabling seamless integration into Siemens TIA Portal-based automation architectures. The front panel meets IP65 protection rating, making it resistant to dust and water ingress from the front.

    The SIMATIC IPC277D is widely deployed in manufacturing, automotive, food and beverage, pharmaceutical, and process industries where a robust operator interface with PC functionality is required. It is commonly used to run Siemens WinCC, WinCC flexible, or third-party SCADA software for process monitoring and control. Its fanless design options and wide operating temperature range make it suitable for installation in control cabinets and production floor environments with limited maintenance access.

    Technical Specifications

    Display Size 15 inch
    Display Technology TFT LCD
    Touch Technology Projected Capacitive (PCT) Multi-Touch, up to 5 touch points
    Display Resolution 1024 x 768 px (XGA)
    Input Voltage 24 V DC
    Power Consumption Approx. 60 W
    IP Protection Rating (Front) IP65
    IP Protection Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Communication Interface 2x Ethernet RJ45, 4x USB 2.0
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC IPC277D
    Operating System Windows Embedded Standard 7 / Windows 7

    Common Error Codes & System Events

    Event ID: 1000
    Application error – a software application running on the Panel PC has crashed or encountered a fatal exception.
    Check Windows Event Viewer for detailed error logs. Restart the affected application or reinstall the HMI software if the issue persists.
    Event ID: 6008
    Unexpected shutdown – the system was not shut down cleanly, indicating a possible power loss or system crash.
    Verify the 24 V DC supply stability and check for voltage dips. Inspect the power supply unit and wiring connections.
    BIOS POST Error
    Hardware component not detected during Power-On Self-Test, such as missing RAM or storage device.
    Reseat memory modules and storage devices. If the error persists, replace the faulty hardware component.
    No Boot Device Found
    The operating system cannot be located on the configured boot device, typically due to a failed SSD/CFast card.
    Check the CFast or SSD storage device in the BIOS. Replace the storage medium and restore the OS image from backup.
    Watchdog Timeout
    The system watchdog timer has triggered a reset because the operating system or application stopped responding.
    Investigate software processes causing system hangs. Update or reinstall the HMI application and check for OS-level issues.
    Temperature Warning
    The internal temperature of the Panel PC has exceeded the warning threshold, risking thermal shutdown.
    Check ambient temperature and ensure adequate ventilation around the unit. Clean any dust from ventilation areas and verify the installation environment is within specified limits.
    Fan Failure
    A cooling fan has stopped operating or is running below the minimum required speed (applicable to fan-cooled variants).
    Replace the defective fan. Ensure the replacement fan is the correct Siemens spare part for the IPC277D variant.
    CFast Card Write Error
    A write operation to the CFast storage card has failed, possibly due to a worn or corrupted card.
    Replace the CFast card with a Siemens-approved industrial-grade CFast card and restore the system image.

    Frequently Asked Questions

    What processor does the SIMATIC IPC277D 6AV7260-1DP30-0BX6 use?

    The IPC277D is based on an Intel Atom processor platform, providing sufficient performance for HMI and SCADA applications while maintaining low power consumption suitable for fanless operation variants.

    What operating systems are supported on this Panel PC?

    The 6AV7260-1DP30-0BX6 supports Windows Embedded Standard 7 and Windows 7, which are compatible with Siemens WinCC and WinCC flexible HMI software as well as many third-party SCADA packages.

    What is the front panel protection rating of this unit?

    The front panel of the IPC277D meets IP65 protection, making it resistant to dust ingress and low-pressure water jets, suitable for installation in production floor environments.

    Can this Panel PC be integrated into a TIA Portal project?

    Yes, the SIMATIC IPC277D can run WinCC Runtime software and be fully integrated into Siemens TIA Portal-based automation projects, communicating with S7 PLCs via Ethernet or PROFINET.

    What storage media does the 6AV7260-1DP30-0BX6 use?

    This Panel PC uses CFast cards or solid-state drives as its primary storage medium, which are more robust than conventional hard drives and better suited to vibration-prone industrial environments.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the power input connector and verify it is within the specified tolerance. Check whether the power LED indicates the unit is receiving power.

    Ensure the 24 V DC supply is stable and within tolerance. If power is confirmed but the display remains blank, the internal power supply board or display backlight inverter may be faulty and require replacement.

    Touch input is unresponsive or inaccurate

    Check whether the issue is present across the entire screen or only in specific zones. Verify that no contaminants such as water or grease are present on the touch surface, as PCT touch can be affected by surface contamination.

    Clean the touch surface with a dry lint-free cloth. If the issue persists, recalibrate the touch controller through the Windows control panel. A persistently faulty touch controller may require replacement of the front panel assembly.

    System fails to boot and displays 'No Boot Device Found'

    Enter the BIOS setup during POST and check whether the CFast card or SSD is detected. A missing or failed storage device will prevent the OS from loading.

    Reseat the CFast card or SSD. If the device is not detected after reseating, replace the storage medium with a compatible industrial-grade unit and restore the operating system image from a backup.

    Panel PC reboots unexpectedly or triggers watchdog resets

    Review the Windows Event Viewer system logs for critical errors or application crashes preceding the reboot. Check the 24 V DC supply for voltage instability or ripple using an oscilloscope.

    Stabilize the power supply if voltage irregularities are found. If the cause is software-related, update or reinstall the HMI application. Persistent hardware-related resets may indicate a failing mainboard.

    Ethernet communication is lost intermittently

    Check the RJ45 connector and cable for physical damage or loose seating. Verify network switch port status and check Windows Device Manager for Ethernet adapter errors.

    Replace the Ethernet cable and ensure the connector is firmly seated. Update the network adapter driver if Device Manager reports errors. If the onboard Ethernet port is faulty, a USB-to-Ethernet adapter can serve as a temporary workaround pending mainboard repair.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart