Siemens 6AV7245-6BA00-0AT0 SIMATIC IPC277D
€ 1.811,00
The Siemens 6AV7245-6BA00-0AT0 is a Panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial-grade embedded Panel PC product line. It is designed for use as a human-machine interface (HMI) and industrial computing platform, combining a multi-touch display with an embedded PC architecture. This unit is built to meet the demanding requirements of continuous industrial operation and integrates seamlessly into Siemens automation environments.
The IPC277D features a widescreen display with resistive or projected capacitive touch technology, an Intel Atom-based processor, and runs Windows Embedded Standard 7 or compatible embedded operating systems. It provides multiple communication interfaces including PROFINET, USB ports, and serial interfaces, enabling connectivity to PLCs, field devices, and higher-level systems. The unit is designed for panel mounting with a robust aluminum front frame and achieves a front-side protection rating of IP65, making it suitable for harsh industrial environments.
The SIMATIC IPC277D is widely deployed in manufacturing automation, process control, and machine tool applications across industries such as automotive, food and beverage, pharmaceuticals, and chemical processing. Its compatibility with Siemens WinCC and other SCADA/HMI software packages makes it a practical choice for visualization and operator control stations. The panel PC form factor allows direct integration into control cabinet doors or operator panels without requiring a separate PC enclosure.
Technical Specifications
| Series | SIMATIC IPC277D |
|---|---|
| Display Size | 15.6 inch widescreen |
| Display Technology | TFT LCD |
| Touch Technology | Resistive touchscreen |
| Display Resolution | 1366 x 768 pixels |
| Display Colors | 16.7 million colors |
| Input Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| Processor | Intel Atom E3827 (dual-core) |
| Communication Interface | 2x PROFINET/Ethernet (RJ45), 4x USB, 1x RS-232/RS-422/RS-485 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| IP Rating (Front) | IP65 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence
Check storage media (CFast or HDD) for integrity. Verify BIOS settings and reseat memory modules. Replace storage device if corrupted. - Event ID: 200
- Overtemperature warning — internal temperature has exceeded the defined threshold
Check ambient temperature and ensure adequate ventilation around the panel. Clean air vents and verify cooling fan operation if applicable. - Event ID: 300
- Supply voltage out of range — 24 V DC input voltage is below or above acceptable limits
Measure input voltage at the power connector. Ensure the power supply unit delivers a stable 24 V DC within the specified tolerance range. - Event ID: 400
- Watchdog timeout — the system watchdog has triggered due to an application or OS hang
Restart the device. Investigate the application or WinCC runtime for software loops or resource exhaustion. Update or reinstall the HMI software if the issue persists. - Event ID: 500
- PROFINET communication error — loss of connection to the configured PROFINET controller
Check Ethernet cable connections and switch/hub integrity. Verify PROFINET configuration in the controller and ensure IP address settings are correct. - Event ID: 600
- Storage media error — read/write error detected on the internal CFast card or hard disk
Back up project data immediately. Run a disk check utility. Replace the CFast card or HDD if hardware failure is confirmed. - Event ID: 700
- Fan failure detected — cooling fan has stopped or is operating below minimum speed
Inspect and clean the fan. Replace the fan module if it is not spinning. Continued operation without cooling may cause thermal shutdown.
Frequently Asked Questions
What operating system does the SIMATIC IPC277D 6AV7245-6BA00-0AT0 run?
This unit is supplied with Windows Embedded Standard 7 (WES7) as the operating system, optimized for industrial HMI applications.
What HMI software is compatible with this Panel PC?
The IPC277D is compatible with Siemens WinCC (TIA Portal), WinCC flexible Runtime, and other SCADA applications that support Windows Embedded Standard 7.
What is the input voltage requirement for this Panel PC?
The device requires a 24 V DC power supply. Ensure the supply is stable and within the specified tolerance to prevent system faults.
Is the front panel of this unit protected against dust and water ingress?
Yes, the front panel achieves an IP65 protection rating, making it resistant to dust and low-pressure water jets, suitable for industrial environments.
Can the internal storage be replaced or upgraded in the field?
The IPC277D uses a CFast card as its primary storage medium, which can be replaced in the field. A replacement card must be loaded with the correct OS image and HMI project.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector using a multimeter. Verify that the power LED indicator is active. Attempt to connect an external monitor via the available video output if present.
If supply voltage is correct but display is blank, the backlight inverter or the display panel itself may have failed. Replace the display assembly or the internal power supply board as appropriate.
Touchscreen does not respond to input
Determine whether the issue is with the touch controller or the display. Check Device Manager in Windows for touch controller driver errors. Clean the screen surface and check for physical damage to the touch overlay.
Recalibrate the touchscreen using the Windows calibration tool. If the touch controller is not recognized, reinstall the touch driver. Replace the touch overlay or the front panel assembly if hardware damage is confirmed.
Unit fails to boot and shows a BIOS or POST error
Check whether the CFast storage card is properly seated. Listen for beep codes during POST. Access the BIOS setup to verify boot order and hardware detection.
Reseat the CFast card and memory modules. If the CFast card is not detected, replace it with a new card loaded with the correct OS image. Update BIOS firmware if a compatibility issue is identified.
PROFINET communication is intermittent or lost
Check the Ethernet cable connections at both the panel PC and the switch or PLC. Use a network diagnostic tool to verify link status and packet loss. Review the PROFINET configuration in TIA Portal for address conflicts.
Replace faulty Ethernet cables. Ensure the PROFINET controller and the IPC277D are on the same subnet with correct IP settings. Restart the PROFINET runtime service or reboot the panel PC.
System overheats and shuts down unexpectedly
Monitor the internal temperature via the SIMATIC IPC DiagBase or DiagMonitor software. Check that ambient temperature is within the 0 to 50 degrees C operating range. Inspect ventilation slots for blockage.
Clean all ventilation openings. Ensure the panel cutout provides adequate clearance for heat dissipation. If a cooling fan is fitted, verify it is operational and replace if faulty.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page