• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7241-5DB02-0EA0 SIMATIC IPC277D
    Awaiting product image

    Siemens 6AV7241-5DB02-0EA0 SIMATIC IPC277D

    € 1.995,00

    Reset
    Clear
    SKU: 6AV7241-5DB02-0EA0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7241-5DB02-0EA0 is a panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial PC product line designed for demanding automation and process visualization environments. This unit is a 15-inch multi-touch panel PC that integrates computing power and HMI functionality into a single compact device. It is designed for front-panel mounting and provides a robust platform for running SCADA, HMI, and process visualization software in industrial settings.

    The IPC277D features a 15-inch widescreen TFT display with a projected capacitive (PCT) multi-touch interface, supporting up to 5 simultaneous touch points for intuitive operator interaction. It is powered by an Intel Atom processor and supports Windows Embedded Standard 7 or Windows 7 operating systems, providing a familiar computing environment for industrial applications. The unit includes multiple communication interfaces such as USB, Ethernet (RJ45), and optionally PROFINET, enabling seamless integration into existing automation networks. The fanless design and solid-state storage options contribute to high reliability and reduced maintenance requirements in harsh industrial environments.

    The SIMATIC IPC277D is widely deployed in manufacturing, automotive, food and beverage, pharmaceutical, and process industries where a reliable, front-panel-mounted HMI with PC functionality is required. It is suitable for use as an operator station in conjunction with Siemens SIMATIC WinCC, WinCC flexible, or third-party SCADA software. The IP65-rated front panel makes it appropriate for environments where dust and water ingress protection is essential.

    Technical Specifications

    Display Size 15 inch
    Display Type TFT widescreen
    Display Resolution 1024 x 768 px
    Touch Technology Projected capacitive (PCT) multi-touch, up to 5 touch points
    Processor Intel Atom
    Operating System Windows Embedded Standard 7 / Windows 7
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 60 W
    Communication Interface 2x USB 2.0, 2x RJ45 Ethernet (10/100/1000 Mbit/s)
    IP/Protection Rating IP65 (front panel)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Mounting Front panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC IPC277D

    Common Error Codes & System Events

    Event ID: 100
    Operating system startup failure or boot error detected during POST.
    Check storage medium (SSD/CFast card) for errors. Verify OS installation integrity and reseat storage device if necessary.
    Event ID: 101
    Hardware component not recognized or driver failure during initialization.
    Check device manager for missing or failed drivers. Reinstall relevant drivers or update BIOS/firmware.
    Event ID: 200
    Watchdog timeout — the system did not respond within the expected time frame.
    Check CPU load and running processes. Reduce system load or reconfigure watchdog timeout settings in BIOS.
    Event ID: 201
    Fan failure detected (if applicable) or thermal warning threshold exceeded.
    Check system temperature and ventilation. Clean any air vents and verify ambient temperature is within specification.
    Event ID: 300
    Network interface communication error or Ethernet link failure.
    Check Ethernet cable connections and network switch. Verify IP configuration and network adapter driver status.
    Event ID: 400
    USB device error or unrecognized USB peripheral connected.
    Disconnect and reconnect the USB device. Try an alternate USB port or verify device compatibility with the IPC277D.
    Event ID: 500
    Storage device read/write error or storage medium nearing end of life.
    Run disk diagnostics on the SSD or CFast card. Replace storage medium if errors persist and restore system image from backup.

    Frequently Asked Questions

    What operating systems are supported by the SIMATIC IPC277D 6AV7241-5DB02-0EA0?

    The IPC277D supports Windows Embedded Standard 7 and Windows 7. Some variants may also support Windows 10 IoT Enterprise depending on the hardware revision.

    What is the input voltage for this panel PC?

    The 6AV7241-5DB02-0EA0 operates on 24 V DC supply voltage, which is standard for Siemens SIMATIC industrial panel PCs.

    Is the touch screen suitable for use with gloves?

    The projected capacitive (PCT) multi-touch screen is optimized for bare finger operation. Glove compatibility depends on glove thickness and material; thin conductive gloves may work but are not guaranteed.

    What HMI software is compatible with this panel PC?

    The IPC277D is compatible with Siemens SIMATIC WinCC, WinCC flexible, WinCC Runtime Advanced, and third-party SCADA or visualization software that runs on Windows.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7241-5DB02-0EA0 is rated IP65, providing protection against dust ingress and low-pressure water jets.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power connector. Verify that the power LED indicator is active. Measure supply voltage with a multimeter to confirm it is within tolerance.

    Ensure the 24 V DC supply is stable and within the specified range. If supply is correct but display remains blank, the internal power supply board or backlight inverter may be faulty and require replacement.

    Touch screen does not respond to input

    Check if the operating system has fully booted and the touch driver is loaded. Inspect the touch controller in Device Manager for errors or driver conflicts.

    Reinstall the PCT touch driver from the Siemens support portal. If the issue persists after driver reinstallation, the touch glass or touch controller board may need replacement.

    System fails to boot and shows a black screen with error message

    Check the CFast card or SSD for physical seating and integrity. Attempt to boot from an external USB drive to determine if the issue is storage-related.

    Reseat the storage medium. If the OS is corrupted, restore the system image using the Siemens recovery partition or a backup image. Replace the storage medium if hardware failure is confirmed.

    Ethernet communication is intermittent or not established

    Check the RJ45 cable and switch port. Verify the IP address configuration in Windows Network Settings. Check the network adapter status in Device Manager.

    Replace the Ethernet cable and test with a known-good switch port. Update the network adapter driver if flagged in Device Manager. If the hardware port is faulty, the unit may require board-level repair.

    System runs slowly or HMI application freezes

    Monitor CPU and RAM usage via Task Manager. Check for background processes consuming excessive resources. Verify that the storage medium is not full and has adequate free space.

    Terminate unnecessary background processes and disable non-essential startup programs. If the CFast card or SSD is nearly full, archive old data and free up space. Consider upgrading storage if performance issues persist.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart