• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7241-3DA00-0DA2 SIMATIC IPC277D
    Awaiting product image

    Siemens 6AV7241-3DA00-0DA2 SIMATIC IPC277D

    € 1.450,00

    Reset
    Clear
    SKU: 6AV7241-3DA00-0DA2 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7241-3DA00-0DA2 is a panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial PC product line designed for demanding automation and process visualization environments. This unit is a 15-inch multi-touch panel PC that integrates computing performance with a robust industrial-grade enclosure, offering a compact all-in-one solution for HMI and SCADA applications. It is manufactured by Siemens as part of the SIMATIC HMI family and is designed to operate reliably in industrial settings with exposure to vibration, dust, and temperature variations.

    The IPC277D features a 15-inch widescreen TFT display with a projected capacitive (PCT) multi-touch interface, supporting up to 4-finger multi-touch operation. It is powered by an Intel Atom processor and supports Windows Embedded Standard 7 or Windows 7 operating systems, providing a familiar computing environment for SCADA and visualization software such as WinCC. The unit includes multiple communication interfaces including USB 2.0 ports, Ethernet (RJ45), and a serial interface, and supports integration into PROFINET networks. The front panel achieves IP65 protection rating, making it resistant to dust and water ingress from the front side.

    The SIMATIC IPC277D is widely deployed in manufacturing automation, process industries, and machine building applications where a reliable, panel-mounted HMI PC is required. It is suitable for use in automotive production lines, food and beverage processing, pharmaceutical manufacturing, and water treatment facilities. Its fanless design option and robust construction make it particularly well-suited for environments where maintenance access is limited and continuous operation is critical.

    Technical Specifications

    Display Size 15 inch
    Display Technology TFT LCD
    Touch Technology Projected Capacitive (PCT) Multi-Touch
    Multi-Touch Support Up to 4-finger multi-touch
    Input Voltage 24 V DC
    Power Consumption Approx. 60 W
    Processor Intel Atom
    Communication Interface 2x Ethernet RJ45, 4x USB 2.0, 1x RS-232/RS-422/RS-485
    Operating System Windows Embedded Standard 7 / Windows 7
    IP Protection Rating (Front) IP65
    IP Protection Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Mounting Panel mounting
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 100
    Operating system startup error or boot failure detected during POST sequence.
    Check storage media (CFast card or HDD) for integrity. Verify OS installation and boot configuration in BIOS settings.
    Event ID: 200
    Overtemperature warning — internal temperature has exceeded the recommended operating threshold.
    Check ambient temperature and ventilation around the panel. Clean air vents and ensure the installation environment is within the 0–50 °C operating range.
    Event ID: 300
    Ethernet communication link failure — no network connection detected on one or both Ethernet interfaces.
    Inspect RJ45 cable connections and switch/hub status. Verify network adapter settings in the operating system Device Manager.
    Event ID: 400
    USB device error — a connected USB peripheral has caused a device fault or is not recognized.
    Disconnect and reconnect the USB device. Try an alternate USB port. Update or reinstall USB device drivers if necessary.
    Event ID: 500
    Storage media error — read/write failure detected on the internal CFast card or hard disk.
    Run a disk check utility (chkdsk) on the storage device. Replace the CFast card or HDD if errors persist or the device is not recognized.
    Event ID: 600
    Power supply undervoltage — the 24 V DC supply voltage has dropped below the permissible operating range.
    Measure the supply voltage at the power connector. Ensure the power supply unit provides a stable 24 V DC within the specified tolerance range.
    Event ID: 700
    Watchdog timeout — the system watchdog has triggered due to an application or OS hang condition.
    Investigate running applications for software faults or infinite loops. Review system event logs and consider restarting the WinCC or SCADA application.

    Frequently Asked Questions

    What is the supply voltage for the Siemens 6AV7241-3DA00-0DA2?

    The unit operates on a 24 V DC supply voltage. Ensure the power source is stable and within the permissible tolerance range for reliable operation.

    What touch technology does the IPC277D use?

    The 6AV7241-3DA00-0DA2 uses projected capacitive (PCT) multi-touch technology, supporting up to 4-finger multi-touch input. This allows intuitive gesture-based interaction with the HMI application.

    Is the IPC277D compatible with Siemens WinCC software?

    Yes, the SIMATIC IPC277D is fully compatible with Siemens WinCC and WinCC flexible SCADA and visualization software, as it runs a Windows-based operating system supported by these packages.

    What is the IP protection rating of this panel PC?

    The front panel of the 6AV7241-3DA00-0DA2 achieves IP65 protection, making it resistant to dust and water jets. The rear of the unit is rated IP20.

    Can the IPC277D be integrated into a PROFINET network?

    Yes, the unit includes Ethernet interfaces that support PROFINET communication, allowing integration into Siemens automation networks alongside S7 PLCs and other PROFINET-compatible devices.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the power connector using a multimeter. Verify that the power LED indicator status is present. Attempt a hard reset by cycling power.

    If voltage is correct and display remains blank, check internal fuse and power supply board. If the backlight has failed, the display assembly or inverter board may require replacement.

    Touch input is unresponsive or inaccurate

    Check for physical damage or contamination on the touch surface. Verify that touch drivers are correctly installed in the Windows Device Manager. Test with a known-good stylus or clean finger.

    Clean the touch screen surface with a soft, lint-free cloth. Recalibrate the touch screen via the Windows control panel. If the issue persists, the PCT touch controller or digitizer assembly may need replacement.

    Unit fails to boot into the operating system

    Listen for POST beep codes and observe any error messages on screen during startup. Access the BIOS to verify that the correct boot device (CFast card or HDD) is detected and selected.

    Replace the CFast card with a correctly imaged replacement if the storage device is not detected. Restore the OS image using a Siemens recovery medium or a pre-imaged replacement CFast card.

    Ethernet communication is not established

    Check the RJ45 cable and verify link LEDs on the Ethernet port. Open Windows Device Manager to confirm the network adapter is recognized and drivers are loaded without errors.

    Replace the Ethernet cable and verify switch port configuration. Reinstall network adapter drivers if the adapter shows a fault in Device Manager. Check PROFINET configuration in the automation project if network-level communication fails.

    System overheating or unexpected shutdowns

    Monitor the internal temperature using the SIMATIC IPC DiagMonitor tool or BIOS hardware monitor. Check that the installation environment temperature is within the 0–50 °C operating range.

    Improve ventilation around the panel cutout and ensure minimum clearances are maintained as specified in the installation manual. Clean any dust from ventilation areas and verify that the fanless thermal design is not obstructed by insulating materials.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart