
Siemens 6AV7241-1BB07-0FA0 SIMATIC IPC277D
€ 1.406,00
The Siemens 6AV7241-1BB07-0FA0 is a panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial PC product line designed for demanding automation and process visualization environments. This unit is a 15-inch widescreen panel PC that integrates computing power and HMI functionality into a single compact device. It is engineered for direct panel mounting and offers a robust, fanless design suitable for continuous industrial operation.
The IPC277D features a 15.6-inch widescreen TFT display with a resolution of 1366 x 768 pixels and resistive or projected capacitive touch technology depending on the variant. It is powered by an Intel Atom processor and supports Windows Embedded Standard 7 or Windows 7 operating systems, with onboard flash memory and optional CFast card storage. Communication interfaces include PROFINET, USB ports, and serial interfaces, enabling seamless integration into Siemens TIA Portal environments and compatibility with SIMATIC WinCC and other SCADA software.
The SIMATIC IPC277D is widely used in the manufacturing, automotive, food and beverage, and chemical processing industries for machine-level HMI and supervisory control applications. Its fanless, sealed front panel design makes it suitable for environments where dust, moisture, and vibration are concerns. The device is commonly deployed on production lines, packaging machinery, and process control stations where reliable visualization and operator interaction are required.
Technical Specifications
| Display Size | 15.6 inch widescreen |
|---|---|
| Display Resolution | 1366 x 768 pixels |
| Display Type | TFT LCD |
| Touch Technology | Resistive touch |
| Processor | Intel Atom |
| Operating System | Windows Embedded Standard 7 / Windows 7 |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 40 W |
| Communication Interface | PROFINET (RJ45), USB 2.0, RS-232/RS-422/RS-485 |
| IP/Protection Rating | IP65 (front panel) |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC IPC277D |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check storage media (CFast card or flash module) for integrity. Re-image or replace the storage medium if corrupted. Verify BIOS settings are correct. - Event ID: 101
- Hardware watchdog timeout — the system did not respond within the watchdog monitoring period.
Check CPU load and running processes. Reduce system load or increase watchdog timeout period in BIOS or application settings. - Event ID: 200
- Temperature warning — internal device temperature has exceeded the warning threshold.
Check ambient temperature and ensure adequate ventilation around the panel PC. Verify that the installation cutout meets specified clearance requirements. - Event ID: 201
- Temperature critical — internal temperature has reached a critical level and may cause shutdown.
Immediately reduce ambient temperature. Inspect for blocked ventilation paths. If the unit has an optional fan, verify it is operational. - Event ID: 300
- UPS (uninterruptible power supply) module fault or battery low condition detected.
Check the UPS module connection and battery charge level. Replace the UPS battery if depleted. Verify 24 V DC supply voltage is within tolerance. - Event ID: 400
- PROFINET communication error — loss of connection to the configured PROFINET controller or network.
Check Ethernet cable connections and network switch status. Verify IP address configuration and PROFINET device name assignment in TIA Portal. - Event ID: 500
- Touchscreen calibration error or touch input not responding correctly.
Recalibrate the touchscreen via the Windows control panel or SIMATIC IPC Tools. If calibration fails, inspect the touch controller connection or replace the touch overlay. - Event ID: 600
- Storage medium write error — failure writing to CFast card or onboard flash memory.
Check available storage space and file system integrity using Windows disk tools. Replace the CFast card if hardware errors are detected.
Frequently Asked Questions
What is the supply voltage for the SIMATIC IPC277D (6AV7241-1BB07-0FA0)?
The unit operates on a 24 V DC supply voltage. Ensure the power supply is within the specified tolerance range to guarantee reliable operation.
Which operating systems are supported by this panel PC?
The IPC277D supports Windows Embedded Standard 7 and Windows 7. The specific OS version installed depends on the factory configuration of the ordered variant.
Is this panel PC compatible with Siemens TIA Portal and WinCC?
Yes, the SIMATIC IPC277D is fully compatible with Siemens TIA Portal engineering software and supports SIMATIC WinCC Runtime as well as WinCC flexible Runtime for HMI visualization.
What is the IP protection rating of the 6AV7241-1BB07-0FA0?
The front panel of the IPC277D achieves IP65 protection, making it resistant to dust ingress and low-pressure water jets, suitable for industrial panel installation.
Can the storage medium be replaced or upgraded in the field?
Yes, the IPC277D supports CFast cards as a replaceable storage medium, allowing field replacement or upgrade without requiring full unit replacement.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the power input connector. Check the internal fuse and verify that the power LED indicator is illuminated.
Restore supply voltage to within the 24 V DC tolerance range. Replace the internal fuse if blown. If the backlight is faulty, the display panel or inverter board may require replacement.
Touchscreen does not respond or responds inaccurately
Verify that the touch overlay is clean and free of moisture or contaminants. Check Device Manager in Windows for touch controller driver errors.
Clean the touch surface with a dry cloth. Recalibrate the touchscreen using the Windows calibration tool or SIMATIC IPC Tools. If the issue persists, replace the touch overlay assembly.
Unit fails to boot or continuously restarts
Connect an external monitor via the available video output to determine if the issue is display-related or OS-related. Check BIOS POST messages for hardware errors.
Re-image the CFast card or onboard flash with a valid OS image. If BIOS reports hardware faults, inspect RAM modules and storage connections. Replace faulty components as indicated.
PROFINET communication is lost intermittently
Check the Ethernet cable and RJ45 connector for physical damage or poor contact. Use TIA Portal diagnostics to identify PROFINET device status and error codes.
Replace the Ethernet cable and ensure the connector is fully seated. Verify the PROFINET device name and IP address configuration. Check network switch port settings for speed and duplex mismatch.
System overheats and shuts down unexpectedly
Check the ambient temperature at the installation location. Inspect the rear of the panel PC for adequate clearance as specified in the installation manual.
Ensure the installation environment does not exceed 50 °C ambient temperature. Provide adequate ventilation clearance around the unit. Clean any dust accumulation from ventilation areas and verify the optional cooling fan is operational if fitted.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX1 TP177B
€ 1.040,00Select options This product has multiple variants. The options may be chosen on the product page



